MAIN AND RETICLE FOCUS DIOPTER

4.
While looking at a light-colored blank wall or similar plain
background, use the Main Focus Knob (Fig. 6) to make the
background out-of-focus. Concentrate on the right-barrel reticle and
rotate the Reticle Focus Diopter (Fig. 6) in either direction until it is
sharp. The binocular is now calibrated to your vision, and the Main
Focus Knob is typically all you'll need to adjust moving forward.

ROTATING/LEVELING RETICLE

5.
Focus on a target image and level the reticle with the horizon using
the Reticle Leveling control (Fig. 6). This control is relatively stiff to
turn to reduce accidental adjustments.
TRIPOD & BRIDGESET IPD STABILIZER MOUNTING
The Match Pro ED offers two ways to attach a tripod mount or the included BridgeSet IPD
Stabilizer. This allows two accessories to be used at the same time.
To attach the binocular to a tripod, unscrew or pull off the cap which covers the threaded
socket (lug) and set it aside in a safe place. Use a compatible binocular tripod adapter
accessory to attach the binocular to any standard tripod horizontally to provide stability
during prolonged viewing.
The BridgeSet IPD Stabilizer allows you to secure your customized IPD or eye-to-eye
width. The accessory can be put in the forward (Fig. 7) or rearward (Fig. 8) lug positions.
To attach the accessory:
1. Open the binocular to the widest point, and ensure the stabilizer is collapsed. If
necessary, use the stabilizer's upper thumb screw (Fig. 11) to adjust leg position. This
will allow easier access to the chosen lug position.
2. Unscrew the cap that covers the threaded socket (lug) (Fig. 9) and set it aside in a safe
place.
3. Rotate the forward thumb screw (Fig. 10) into the lug. Use the included hex key to
tighten further, be sure not to overtighten.
4. Readjust the binocular IPD back to your setting (see IPD adjustment on Page 4).
5. Expand the stabilizer legs by rotating the upper thumb screw (Fig. 11) until they
contact the bottoms of both binocular barrels.
Fig. 9
Threaded socket cap cover
Main Focus
Knob
Reticle
Focus
Diopter
Fig. 11
Upper thumb screw
Fig. 10
Forward thumb screw
Click here to return to the Table of Contents
Reticle
Leveling
Figure 6
Fig. 7 Forward Lug position
Fig. 8 Rearward Lug position
BridgeSet IPD
Stabilizer collapsed
BridgeSet IPD
Stabilizer expanded