Configuration Switches

2.6
NOTE: The configuration switches are read only
during power-up.
Set the switches before
delivering power to the control.
The control reads the configuration switches only when the
unit is powering up. To change a setting, disconnect input
power, set the switch, and then reconnect power. The OFF
position is to the Left and the ON position is to the Right (See
Figure 1). Switch descriptions are given in the following table:
OFF Setting
Switch: Description:
Counter-Clockwise*
1
Rotation Direction
Mode ZPA/ZIP
ZPA
2
Zone Type
3
Exit/Transport
Target Speed
4
(with SW5 & SW6)
Target Speed
5
(with SW4 & SW6)
Target Speed
6
(with SW4 & SW5)
Motor Selection
UD048
7
Braking & ZMH
Enabled
8

Table 4: Configuration Switch Settings

*NOTE: The direction of rotation is defined when
viewed from the back side of the motor with the
shaft extending away from the viewer.

Upstream Cable Connection

2.7
This RJ-25 connector is intended for use with a 6-wire
modular phone cable to connect to an adjacent upstream
ZoneLogix control. See Section 5.3 for information on the 6-
Wire Modular Cable Orientation. The Modular RJ-25 Cable is
not provided.

Downstream Cable Connection

2.8
This RJ-25 connector is intended for use with a 6-wire
modular phone cable to connect to an adjacent downstream
ZoneLogix control. See Section 5.3 for information on the 6-
Wire Modular Cable Orientation. The Modular RJ-25 Cable is
not provided.

Mounting Plate/Heat Sink

2.9
This component is for mounting the control assembly to the
conveyor frame using two ¼ inch (6.35 mm), bolts to keep
the controller cooler.
CAUTION:
If mounting the control on a curved section
of conveyor, use washers between the mounting plate
and the conveyor frame. This is to assure that the
mounting plate is not distorted, causing damage to the
enclosed printed circuit board assembly.
ON Setting
Clockwise*
ZIP
Entry/Transport
See Table 6: Operating Speed.
UD060
Disabled

Cover

2.10
CAUTION: Removal of the cover will void the warranty. The
cover does not make the control waterproof or dustproof.
The cover can help reduce the severity of damage to the
control from foreign objects.
3

Installation Guide

This section describes how to install and use the Control and
UniDrive® Motor in the most common configurations.

1. Mount the Control

2. Select a Motor
3. Select a Speed
4. Configure the Location
5. Configure the Operating Mode
6. Configure the Rotation
7. Configure Communications
8. Connect User Input/ Output
Mount the Control
3.1
Mount the control in a location where the motor cable
reaches the motor connector without putting strain on the
connector.

Select Motor Rating Being Used

3.2
Select the motor you will be using. Properly match the control's motor
selection to the motor that is actually being operated by the control.
In addition to the standard 48 watt UniDrive® motor, this control
provides increased performance with our 60 watt UniDrive motor with
its higher operating speed.
SW7:
Motor:
OFF
UD048
ON
UD060

Table 5: Motor Selection Switch Settings

ZoneLogix Control, ACG P/N 301216 July 23, 2021 Page 6
Comments:
Previously 100W24
Previously 125W24