Summary of Contents for TENA SmartCare Change Indicator
Page 1
TENA SmartCare Change Indicator ™ Family caregivers Instructions for use www.tena.com IFU TENA SmartCare Change Indicator Family caregivers Version: 2022-09-07...
Remove the Change Indicator TENA SmartCare Change Indicator is a system consisting of: Intended use • An app named TENA SmartCare Family Care that can be installed on one or more smartphones used in a family. List of supported TENA products •...
Page 3
Change Indicator. SmartCare Support. • The Change Indicator should be attached to the outside of the • The Change Indicator is intended for use with TENA incontinence incontinence product. products. • Clean the Change Indicator when fully assembled to prevent water • ...
The transmitter code is located on (see supported TENA products on p. 16 Care app, iOS 11 / Android 7 the back of the transmitter and on of this guide or in the TENA SmartCare or later. the packaging. Family Care app).
The Change Indicator must be within 10 m/33 ft from a gateway to be monitored by the system. Placement – no action needed The absorbent core of the TENA product is dry and the surface feels dry to the skin. 10 m/ 33 ft Screws or...
000 000 000 000 000 SN (21) 000 000 000 000 000 lights & buttons WARNING Only CR2032 batteries shall be used in the TENA SmartCare Change Indicator. Find the transmitter code, which Enter the transmitter code is located on the back of the in the TENA SmartCare Family Care transmitter and on the packaging.
Attach the Change Indicator Use the Change Indicator See supported TENA absorbent products on p. 16 of this guide or in the Press both buttons simultaneously for two seconds at every TENA SmartCare Family Care app. change. This records the change of incontinence product in the TENA SmartCare Family Care app.
Intended use Intended Use: The TENA SmartCare Change Indicator™ is an accessory to absorbent incontinence products, intended for use on individual(s) suffering from urinary incontinence in a home or professional environment who are dependent on one or more caregivers to change the absorbent incontinence products.
TENA products TENA Slip CHECK Ensure you have the correct sensor strip length for your TENA product. Only products with a textile-like outer lining can be used with the Change Indicator. The TENA SmartCare Change Indicator™ should always be attached when the incontinence product is folded and before it has been applied to the user.
TENA Flex TENA Pants The TENA SmartCare Change Indicator™ should always be attached when the The TENA SmartCare Change Indicator™ should always be attached when the incontinence product is folded and before it has been applied to the user. incontinence product is folded and before it has been applied to the user.
The sensor strip is designed to withstand up to 12 weeks of continuous use. Sometimes, The TENA SmartCare Change Indicator™ should always be attached when the however, the hooks on the back of the sensor strip can become covered with fibres or lint.
Do not clean in the washing machine. Blinking blue-green-red light: Do not submerge in water. pull out the power. Wait 30sec. Insert the power. Wait 2min. If the error persists, contact TENA SmartCare support.
The transmitter is not attached running again. No light: OK properly or the battery is low. 6. If this does not help, please contact TENA The light disappears after a few Try re-attaching the transmitter. seconds. Check for power by If it does not help, change the SmartCare support.
Page 14
1. Make sure you are using one of the is a steady light for a few seconds, Indicator Indicator supported TENA incontinence products with everything is OK. falls off a textile-like outer lining. The Change b. If there is a blinking light, check that the...
Page 15
Family Care app. already too full of urine to be comfortable. 3. If this does not help, please contact TENA SmartCare Support. 1. Make sure you are using one of the supported TENA products (see p. 16 of this guide).
WEEE Directive. For more information, Lifetime please contact the manufacturer at www.tena.com. • Read best before date on accompanying packaging. • The product will be labelled with the WEEE mark as shown on the side, • ...
Labelling symbols Assortment overview The following symbols may appear on your TENA SmartCare Change Indicator™, accessories and/or packaging: ARTICLE LIST FOR IFU Manufacturing date Unique Device 8537 TENA SmartCare transmitter Information 8541 TENA SmartCare sensor strip 1 Manufacturer Not MR safe...
Page 19
SmartCare Support, UK: support.smartcare@tena.co.uk Essity Hygiene and Health AB SE-405 03 Göteborg, Sweden Visiting address: Mölndals bro 2, Mölndal www.essity.com TENA an Essity brand...
Need help?
Do you have a question about the SmartCare Change Indicator and is the answer not in the manual?
Questions and answers