Summary of Contents for TENA SmartCare Change Indicator

  • Page 1 TENA SmartCare Change Indicator ™ Professional caregivers Instructions for use www.tena.com 110786-5MA003-12 IFU TENA SmartCare Change Indicator Professional caregivers Version: 2020-01-28...
  • Page 2: Table Of Contents

    Information Contents Information This guide is intended for professional caregivers, super users and managers using the TENA SmartCare Change Indicator™ in a nursing home Contents environment. The Change Indicator system tracks and displays urine Important information saturation levels in absorbent TENA incontinence products.
  • Page 3: Important Information

    Change Indicator. •  S eekimmediatemedicalcareifthebatteryisswallowed. •  D onotattempttorepairormodifytheChangeIndicatororGateway by yourself. •  I fanypartoftheChangeIndicatorsystemappearstobedamaged or broken, it should not be used. Contact TENA for support. Continues on next page TENA SmartCare Change Indicator TENA SmartCare Change Indicator...
  • Page 4: Tena Smartcare Change Indicator Components

    A supported TENA incontinence product. A handheld device/dashboard with the (See supported TENA products on page TENA SmartCare Professionals 18–23 in this guide or in the TENA software/app, iOS 11 and later. SmartCare Professionals app). CONSUMABLES: Sensor strip short, sensor strip medium, sensor strip long, battery.
  • Page 5: Download App And Set Up Account

    Toprotecttheirprivacy,residentsareidentifiedbytheirroomnumbersratherthantheir residents from the system and create names. In the TENA SmartCare Professionals app, beside each resident’s room number, various reports. caregivers will see a status icon for that particular resident. Functions in the app and dashboard...
  • Page 6: Dashboard Setup And Pages

    The Statistics pageofferstwodifferentwaystoviewresponsetimesto“change”notifications – a bar chart and a grid. Both options enable the user to select a particular day or resident (byclickingonthe“History”icon)andthenviewnotificationsandresponsetimesrelatingto this resident. See page 26 Gatewaylights&buttons TENA SmartCare Change Indicator TENA SmartCare Change Indicator...
  • Page 7: Register Transmitter Code

    Professionals dashboard See page 27 Transmitter lights &buttons WARNING Only CR2032 batteries shall be used in the TENA SmartCare Change Indicator.   Find the transmitter code, which   E nterthetransmittercodein is located on the back of the the dashboard. IPXX transmitter or on the packaging.
  • Page 8: Attach Change Indicator

    See list of supported products on page 18–23 in this guide or in the app. Press both buttons simultaneously for two seconds at every change. This records the change of incontinence product in the TENA SmartCare Professionals app and on the dashboard and resets the system. Find the front...
  • Page 9: Remove Change Indicator

    Remove Change Indicator Intended use Intended Use: The TENA SmartCare Change Indicator is an accessory to absorbent incontinenceproducts,intendedforuseonindividual(s)sufferingfrom IPXX urinary incontinence in a home or professional environment who are FCC ID: dependent on one or more caregivers to change the absorbent NOTE incontinence products.
  • Page 10: Attachment Instructions For Supported Tena Products

    Plus, Super or Maxi Plus, Super or Maxi The TENA SmartCare Change Indicator should always be attached when the The TENA SmartCare Change Indicator should always be attached when the incontinence product is folded and before it has been applied to the user.
  • Page 11: Tena Stretch Brief

    Super or Ultra Plus or Super The TENA SmartCare Change Indicator should always be attached when the The TENA SmartCare Change Indicator should always be attached when the incontinence product is folded and before it has been applied to the user.
  • Page 12: Tena Brief

    TENA Comfort Super or Ultra The TENA SmartCare Change Indicator should always be attached when the incontinence product is folded and before it has been applied to the user. The TENA SmartCare Change Indicator should always be attached when the incontinence product is folded and before it has been applied to the user.
  • Page 13: Change Sensor Strip & Battery

    IPXX Ifyouhavedifficultyremovingthebattery,tapthe Do not clean in the washing machine. IPXX FCC ID: transmitter in your hand until the battery falls out. Do not submerge in water. FCC ID: UDI: UDI: TENA SmartCare Change Indicator TENA SmartCare Change Indicator...
  • Page 14: Gateway Lights & Buttons

    Applying the Change Indicator to the incontinence product EverythingisOK. Press both buttons simultaneously for two seconds at every change. This records the change of incontinence product in the TENA SmartCare Professionals app and on the dashboard and No light: resets the system.
  • Page 15: Water, Sand And Dirt

    IPXX Super user: FCC ID: 1. Repeat steps 1–4 above 2. If this does not help, contact TENA UDI: SmartCare support. Connection Change Caregiver: error Indicator 1.
  • Page 16 “Connection error” in the strip. Press both buttons simultaneously TROUBLESHOOTINGsectionofthisguide. again. If there is a steady light for a few 3. If this does not help, contact TENA seconds,everythingisOK. SmartCare support. 5. If this does not help, (no light or blinking...
  • Page 17 – no action needed administrative dashboard. 3. “Some urine” Some urine detected, but the 3. If this does not help, please contact TENA surface of the product is still dry. SmartCare Support. 4. “Saturated” The absorbent product is near saturation –...
  • Page 18 Change Indicator administrative dashboard. is soiled. 3. If this does not help, please contact TENA 4. Remove lint from the Velcro-covered side SmartCare Support. when required. This will ensure the Change Indicator stays securely attached to the I don’t...
  • Page 19: Operating Characteristics

    +15 °C +45 °C TYPE CAPACITY / VOLTAGE Operating humidity 15% Rh 90% Rh (non-condensing) CR2032 220 mAh/3.0 V nominal Pressure 700 hPa 1060 hPa This value is with recommended battery: CR2032 TENA SmartCare Change Indicator TENA SmartCare Change Indicator...
  • Page 20: Electromagnetic Compability (Emc)

    •  T hisproducthasbeendesignedwithrecycling,reuse,andwastemanagementasa consideration. Essity will provide the necessary information to recycling facilities and government agencies as required by WEEE Directive. For more information, please contact Essity at www.tena.com. Lifetime •  T heproductwillbelabelledwiththeWEEEmarkingasshownontheside, in accordance with European Standard EN 50419.
  • Page 21 FCC ID: Labeling symbols UDI: The following symbols may appear on your TENA SmartCare Change Indicator, accessories and/or packaging: IP54 IPXX Manufacturing date IPClassification FCC ID: FCC ID number Manufacturer IC ID number UDI: Unique Device Instruction manual Information IPXX FCC ID: WEEE-marking.
  • Page 22 TENA SmartCare Change Indicator TENA SmartCare Change Indicator...
  • Page 23 This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Essity Hygiene and Health AB Essity Hygiene and Health AB SE-405 03 Göteborg, Sweden...