Foot control valve (for Offset Boom) (CX75SR)
Manufacturer....................................................................................................................................... Nishina industrial
Operating pressure .......................................................................................................................... 3.92 MPa (569 psi)
Secondary pressure, primary short type .......................................................... 0.64 to 2.45 MPa (92.82 to 355.34 psi)
Operating angle ..................................................................................................................................................... 12.4°
Operating torque............................................................................................................................ See the figure below
Lep SC75SRCX80-1002-0NA
Secondary
pressure
Operating angle (deg.)
Push rod stroke (mm) (in)
1002-19