1002-14
Offset left (CX75SR)
Offset Boom with blade ..................................................................... 33.3 ± 0.3 MPa (4830 ± 44 psi) at 20 L/min
Main relief set pressure ................................................................................. 29.4 ± 0.3 MPa (4260 ± 0.4 psi) at 44 L/min
Functions
Travel priority
Boom up / arm 2 pumps internal flow
Boom load holding circuit
Arm-in forced regenerative circuit
Swing priority
2 pumps flow is joined at reserve section
Lep SC75SRCX80-1002-0NA
Issued 03-08