  • Page 2: Table Of Contents

    Table of Contents Safety Precautions Safety Precautions........................Energy Rating Information Energy Rating Information......................11 Installation Instructions Preparation..........................Design Notice........................... Ambient Temperature Range For Unit Operating..............Exhaust Hose Installation......................Choosing The Right Location....................Tools Needed........................... Accessories..........................Window Installation Kit......................Installation..........................Operating Instructions Control Panel Features......................
  • Page 3: Safety Precautions

    Safety Precautions Read Safety Precautions Before Operation and Installation To prevent death or injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause death, harm or damage. CAUTION WARNING This symbol indicates the possibility of...
  • Page 4 • If the air conditioner is knocked over during use, turn off the unit and unplug it from the main power supply immediately. Visually inspect the unit to ensure there is no damage. If you suspect the unit has been damaged, contact a technician or customer service for assistance.
  • Page 5 • To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device. • The appliance should be installed in accordance with national wiring regulations. • Contact the authorized service technician for repair or maintenance of this unit. •...
  • Page 6 Remark When using this dehumidifier in European countries, the following information must be followed: Disposal: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, there are several possibilities: •...
  • Page 7 • Compliance with national gas regulations should be observed. Keep ventilation openings clear of obstruction. • The appliance should be stored so as to prevent mechanical damage from occurring. • A warning that the appliance should be stored in a well-ventilated area where the room size corresponds to the room area as specified for operation.
  • Page 8 6. Information on servicing 1) Check the area Prior to beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimised. For repair to the refrigerating system, the following precautions should be complied with prior to conducting work on the system.
  • Page 9 8. Check the electrical devices Repair and maintenance to electrical components should include initial safety checks and component inspection procedures. If a fault exists that could compromise safety, then no electrical supply should be connected to the circuit until it is satisfactorily dealt with. If the fault cannot be corrected immediately but it is necessary to continue operation, an adequate temporary solution should be used.
  • Page 10 suspected, all naked flames should be removed/ extinguished. If a leakage of refrigerant is found which requires brazing, all of the refrigerant should be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak.
  • Page 11: Energy Rating Information

    17. Labelling Equipment should be labelled stating that it has been de-commissioned and emptied of refrigerant. The label should be dated and signed. Ensure that there are labels on the equipment stating the equipment contains flammable refrigerant. 18. Recovery When removing refrigerant from a system, either for servicing or decommissioning, it is recommended good practice that all refrigerants are removed safely.
  • Page 12: Installation Instructions

    What should I look for first when purchasing a portable air conditioner? The right air conditioner helps you cool a room efficiently. An undersized unit won't cool adequately while one that's too large will not remove enough humidity, leaving the air feeling damp.
  • Page 13: Design Notice

    Design Notice In order to ensure the optimal performance of our products, the design specifications of the unit and remote control are subject to change without prior notice. Ambient Temperature Range For Unit Operating Mode Temperature Range Cool 62°F ~ 95°F (17°C ~ 35°C) 55°F ~ 95°F (13°C ~ 35°C) Exhaust Hose Installation...
  • Page 14: Tools Needed

    Tools Needed • Medium Philips screwdriver • Tape measure or ruler • Knife or scissors • Saw (optional, to shorten window adaptor for narrow windows) Accessories Part Description Quantity Unit adaptor 1 pc Exhaust hose 1 pc Window slider adaptor 1 pc Bolt 1 pc...
  • Page 15: Window Installation Kit

    Window Installation Kit Window installation: Step One: Preparing the Exhaust Hose Assembly Exhaust Hose Exhaust Hose Assembly Press the exhaust hose into the window slider adaptor and unit adaptor. The adaptors should snap in place. Unit Adaptor Window Slider Adaptor Hole Seat Hook Step Two: Install the Exhaust Hose Assembly to...
  • Page 16 Page 16...
  • Page 17: Operating Instructions

    Note: To ensure proper function,do not overextend or bend the hose. Make sure that there is no obstacle around the air outlet of the exhaust hose (in the range of 500mm) in order to the exhaust system works properly. All the illustrations in this manual are for explanation purpose only. Your air conditioner may be slightly different.
  • Page 18: Operation Instructions

    SLEEP operation Operation Instructions COOL operation This feature can be activated from the remote control only. Press the sleep button • Press the 'MODE' button until the 'COOL' on the remote to increases the set indicator light comes on. temperature by 1°C/ 2°F (or 1°F) in 30 •...
  • Page 19 Water drainage • During dehumidifying modes, remove the • When the water level of the bottom tray drain plug from the back of the unit, install the reaches a predetermined level, the unit beeps drain connector (5/8inch universal female 8 times, the digital display area shows 'P1' .
  • Page 20: Maintenance

    Maintenance Safety Precautions • Always unplug the unit before cleaning or servicing. • Do not use flammable liquids or chemicals to clean the unit. • Do not wash the unit under running water. Doing so causes electrical danger. • Do not operate the machine if the power supply was damaged during cleaning. A damaged power cord must be replaced with a new cord from the manufacturer.
  • Page 21: Troubleshooting Tips

    Troubleshooting Tips Problem Possible Causes Solution The Water Collection Tray is full. Turn off the P1 Error Code unit, drain the water from the Water Collection Tray and restart the unit Unit does not turn on when pressing In COOL mode: room ON/OFF button temperature is lower than Reset the temperature...
  • Page 22: Warranty

    The design and specifications are subject to change without prior notice for product improvement. Consult the seller or manufacturer for details. Two years parts and labor call 1 866 646 4332 customerserviceusa@midea.com Exclusively Distributed By: To Reorder: HD Supply Facilities Maintenance, Ltd. Atlanta, GA 30339 1-800-431-3000 hdsupplysolutions.com...