Download Print this page

Advertisement

Quick Links

IMPORTANT NOTE:
Before using your air conditioner, please read
this manual carefully and keep it for future reference.
Exclusively Distributed By:
HD Supply Facilities Maintenance, Ltd.
Atlanta, GA 30339
© 2022
Made in China
INSTALLATION INSTRUCTIONS
SW05M1
To Reorder:
1-800-431-3000
hdsupplysolutions.com

Advertisement

loading

Summary of Contents for SeasonsComfort SW05M1

  • Page 1 INSTALLATION INSTRUCTIONS SW05M1 IMPORTANT NOTE: Before using your air conditioner, please read • this manual carefully and keep it for future reference. Exclusively Distributed By: To Reorder: HD Supply Facilities Maintenance, Ltd. Atlanta, GA 30339 1-800-431-3000 hdsupplysolutions.com © 2022 Made in China...
  • Page 2: Table Of Contents

    Table of Contents Important Safety Instructions ...........03 Installation Instructions..............13 Normal Sounds................27 Air Conditioner Features............28 Care and Cleaning...............33 Troubleshooting Tips..............34...
  • Page 3: Important Safety Instructions

    Important Safety Instructions READ THIS MANUAL Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner.
  • Page 4 CAUTION When the air filter is to be removed, do not touch the metal parts of the unit. It may cause an injury. Do not put a pet or house plant where it will be exposed to direct air flow. This could injure the pet or plant. Ventilate the room well when used together with a stove, etc.
  • Page 5 NOTE: The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section Operation of Current Device for details.In the event that the power supply cord is damaged, it cannot be repaired-it must be replaced with acord from the Product Manufacturer.
  • Page 6 Operation of Current Device (Applicable to the unit adopts current detection device only ) The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following: 1. Plug in the Air Conditioner. 2.
  • Page 7 -Servicing shall only be performed as recommended by the equipment manufacturer. Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the person competent in the use of flammable refrigerants. -DO NOT modify the length of the power cord or use an extension cord to power the unit. DO NOT share a single outlet with other electrical appliances.
  • Page 8 WARNINGS (for using R290/R32 refrigerant only) 1.Transport of equipment containing flammable refrigerants See transport regulations 2.Marking of equipment using signs See local regulations 3.Disposal of equipment using flammable refrigerants See national regulations. 4.Storage of equipment/appliances The storage of equipment should be in accordance with the manufacturer's instructions. 5.Storage of packed (unsold) equipment Storage package protection should be constructed such that mechanical damage to the equipment inside the package will not cause a leak of the refrigerant charge.
  • Page 9 WARNINGS (for using R290/R32 refrigerant only) 7)ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
  • Page 10 WARNINGS (for using R290/R32 refrigerant only) Ensure that seals or sealing materials have not degraded such that they no longer serve the purpose of preventing the ingress of flammable atmospheres. Replacement parts shall be in accordance with the manufacturer's specifications. NOTE: The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment.
  • Page 11 WARNINGS (for using R290/R32 refrigerant only) Open the circuit by cutting or brazing. The refrigerant charge shall be recovered into the correct recovery cylinders. The system shall be flushed with OFN to render the unit safe. This process may need to be repeated several times.
  • Page 12 WARNINGS (for using R290/R32 refrigerant only) j)When the cylinders have been filled correctly and the process completed, make sure that the cylinders and the equipment are removed from site promptly and all isolation valves on the equipment are closed off. k)Recovered refrigerant shall not be charged into another refrigeration system unless it has been cleaned and checked.
  • Page 13: Installation Instructions

    Installation Instructions The unit you purchased may be look like one of the followings: NOTE: NOTE: All the illustrations in this manual are for explanation purpose only. The air conditioner you have may be slightly different. The actual shape shall prevail. ...
  • Page 14 Installation Instructions (for 5000 to 12000Btu/h) BEFORE YOU BEGIN Read these instructions completely and carefully. 6000~8000Btu/h 10000~12000Btu/h 5000~6000Btu/h Model MPORTANT-Save these instructions for local inspector’s use. 14 (356mm) 15-1/2 (394mm) 13 (330mm) IMPORTANT-Observe all governing codes Ta b le 1 and ordianaces.
  • Page 15 C: Align the hole in the top rail with those in the PREPARE THE WINDOW top of the unit as shown in Fig.B Lower sash must open sufficiently to allow a clear Fig.B vertical opening of 13 inches (330mm). Side louvers and the rear of the AC must have clear air space to allow enough airflow through the condenser, for heat removal.
  • Page 16 B. Slide the free end " I" section of the panel SECURE THE ACCORDION PANELS directly into the cabinet as shown in Fig. 2. Slide the panel down. Be sure to leave enough A. Keep a firm grip on the air conditioner, space to slip the top and bottom of the frame carefully place the unit into the window into the rails on the cabinet.
  • Page 17 INSTALL R1 HARDWARE (only applicable to ≥15000Btu/h Energy star models ) In order to minimize air leaks and ensure optimal insulation, it is necessary to install the included Fig.7A Fig.7B R1 hardware to the side curtain. Follow the instructions below. DRIVE LOCKING SCREWS Step 1.
  • Page 18 Step 3. Slide the R1 insulation panel into the side If AC is Blocked by Storm Window curtain, the side with pattern should facing the indoor side.(Fig.13) Add wood as shown in Fig.15, or remove storm window before air conditioner is installed.
  • Page 19 Preliminary Instructions Installation Instructions (for 15000 to 28500Btu/h) Window Sash Seal Safety Lock and 3 /4 (or1/2 ) Long Hex Head Screw BEFORE YOU BEGIN Top Angle Foam Gasket Read these instructions completely and Washer Head Locking screw carefully. IMPORTANT-Save these instructions for Frame Assembly (Left)
  • Page 20 Check your storm windows-- if your A. Window Mounting storm window frame does not allow the clea- rance required, correct by adding a piece of Remove Air Conditioner from Cabinet wood as shown in Fig.E,or by removing storm NOTE: Remove any packaging material from window while room air conditioner is being cabinet exterior.
  • Page 21 10. Your unit may come with internal packaging. Air Conditioner Plastic Cabinet This packaging must be removed prior to installing Frame View the air conditioner back into the cabinet.(see Fig .7). Locking Screw "Ⅰ" Section Shipping Packaging Hole Window Filler Panel Fig.10 Plastic tie...
  • Page 22 1 2 Long Screws Left And Locknuts 3 4 (or1 )Long Hex-head Screw Locknut Sill Angle Right Bracket Flat Head Bolt Fig.13 Fig.13B 2 Each Required For Each Support Bracket Install Support Bracket Fig.15B 1. Hold each support bracket flush against outside 3.
  • Page 23 4. Attach the top angle to window frame: Use a 3. Attach the Lock Frames to the winow sill 3/32" drill bit to drill one hole through the hole using two 3/ 4 " (19mm) screws(Fig.18C) in the middle of top angle into the window frame, (on some models) and drive one 3/ 4 "...
  • Page 24 Install Chassis into Cabinet and Install Front to Unit 1. Lift air conditioner and carefully slide into cabinet leaving 6 inches protruding. 2. DO NOT push on controls or finned coils. 3. Be sure chassis is firmly seated towards rear of cabinet.
  • Page 25 WIDTH " X"= inside model width plus twice the B. Thru-The-Wall Installation thickness of framing material used. HEIGHT '' Y " = inside model height plus twice NOTE: Consult local building codes prior to the thickness of framing material used. installation or a qualified carpenter.
  • Page 26 5. Screw or nail cabinet wooden frame using shims Prepare and Install Cabinet if frame is oversized to eliminate distortion. See 1. Slide chass is from cabinet. Refer back to Fig.8.Remember to maintain proper slope as Step one of Window Mounting. described in Step 3.
  • Page 27: Normal Sounds

    Normal Sounds Pinging or Switching Vibration Droplets of water hitting condenser during High Pitched Chatter Unit may vibrate and make noise normal operation may cause “pinging or swishing” sounds. This noise can be reduce by because of poor wall or window High efficiency compressors removing the water plug at the bottom of unit's “construction or incorrect ”installation.
  • Page 28: Air Conditioner Features

    Air Conditioner Features To begin operating the air conditioner, WARNING follow these steps: 1. Set the thermostat to the highest number To reduce the risk of fire, electric shock, or (coldest or cooler setting). injury to persons, read the IMPORTANT 2.
  • Page 29 Fresh Air Vent Control (on 15~28.5K models): Fig. A (VENT CLOSED) Fig. B Fig. C (VENT OPEN) (VENT & EXHAUST OPEN) The Fresh Air Vent allows the air conditioner to: 1. Recirculate inside air - Vent Closed (See Fig.A) 2. Draw fresh air into the room- Vent Open (see Fig.B) 3.
  • Page 30 ELECTRONIC CONTROL OPERATING INSTRUCTIONS Different models have different control buttons and indicator lights. Not all the control buttons NOTE: and indicator lights describing below are available for the unit you purchased. Please check the control panel of the unit you purchased. The unit can be controlled by the unit control alone or with the remote. TEMP/TIMER Auto Auto...
  • Page 31 FOLLOW ME FEATURE: SLEEP FEATURE: (on some models) Press Sleep button to initiate the sleep mode. Light flashes or In this mode the selected temperature will illuminates Follow ° increase (cooling) or decrease (heating) by 2 ° (or 2) C 30 minutes after the mode is selected. This feature can be activated from the remote The temperature will then increase (cooling) or control ONLY.
  • Page 32 To operate on Auto feature: • Turning the unit ON or OFF at any time or a • When you set the air conditioner in AUTO mode, djusting the timer setting to 0.0 will cancel the it will automatically select cooling, heating(cooling Auto Start/Stop timed program.
  • Page 33: Care And Cleaning

    Care and Cleaning The air filter should be checked at least once a CAUTION month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an Clean your air conditioner occasionally to accumulation of frost on the cooling coils. keep it looking new.
  • Page 34: Troubleshooting Tips

    TROUBLESHOOTING TIPS Before calling for service, review this list. It may save your time and expense. This list includes common occurrences that are not the result of defective workman-ship or materials in this appliance. Problem Solution Air conditioner Wall plug disconnected. Push plug firmly into wall outlet. does not start House fuse blown or circuit breaker tripped.
  • Page 35 Problem Solution Water dripping Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. INSIDE when unit Refer to installation instructions - check with installer. is cooling. Water dripping Unit removing large quantity of moisture from humid room. This is normal during OUTSIDE when excessively humid days.
  • Page 36 LIMITED WARRANTY YOUR PRODUCT IS PROTECTED BY THIS WARRANTY: THE CONSUMER WILL BE RESPONSIBLE WARRANTY PERIOD COVERAGE: FOR: FULL TWO-YEAR Pay all costs for repairing or replacing Costs of service calls that are listed WARRANTY parts of this appliance which prove to be under NORMAL RESPONSIBILITIES Two years from original purchase date.