Mounting; Power - Cardinal CLiC WD-02.1.4 Installation Manual

Glass controller
Table of Contents

Advertisement

CHAPTER 3 – INSTALLATION
MOUNTING 
The CLiC WD‐02.1.4 Glass Controller can be mounted within an enclosure or free standing. The WD‐02.1.4 does not 
need to be mounted near the CLiC Glass panel. The CLiC Glass output and the dry contact input can be extended up 
to 100 meters (328 feet). 
Mounting Pattern Drawings 
 
 
 
POWER 
D
O NOT APPLY POWER PRIOR TO COMPLETING ALL WIRING CONNECTIONS AND TERMINATIONS
A
CLiC
LL PROTECTIVE FILMS MUST BE REMOVED FROM THE 
 GLASS PANEL PRIOR TO CONNECTING THE WD‐
!
02.1.4 GLASS CONTROLLER
 
 
The included power supply (A/C Adapter) should be connected to the '24 VDC in' and 'Ground' input terminals on 
the WD‐02.1.4. The terminal connector will be pre‐attached to the power supply. The CLiC WD‐02.1.4 will power on 
and begin functioning upon applying power.  
Use the provided UL Listed Class 2 power supply with a 24 VDC power output for connection to this control. All wiring 
and installation shall be in accordance with the NEC. Do not connect more than one WD‐02.1.4 to a power supply. 
 
 