Instruction Manual
1. Safety Instructions
• The device is not recommended to be placed on low thermal conductive surface, for example, plastics.
• For safety reasons, please ensure the mounted device is kept at ≥ 8mm safety distance at all sides from other
components and equipments (Refer to Fig. 2). Please insert an insulation sheet between the system and product, if the
safety distance is < 8mm for D2*.
• Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power
supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning!
• Do not touch the terminals while power is being supplied. Risk of electric shock.
• Prevent any foreign metal, particles or conductors to enter the device through the openings during installation. It can
cause: Electric shock; Safety Hazard; Fire; Product failure.
• Warning: The power supply must be mounted by metal screws onto a grounded metal surface. It is highly recommended
that the Earth terminal on the connector be connected to the grounded metal surface.
For optimum EMI performance, the two mounting holes (marked Ⓑ in Fig. 1) need to be connected together to the
system's protective earthing (PE). Protective bonding conductor from the end product protective earth terminal can be
tied to the input FG (marked Ⓑ in Fig. 1). Under this mounting condition, there is no galvanic isolation between Output
to FG.
2. Device Descriptions
Refer to Fig. 1.:
Description
PIN No.
① Input connector (CN1)
1
2
3
② Output connector (CN2)
1
2
3
4
③ Output connector (CN3)
1
2
3. Installation of the Device
Refer to Fig. 1.:
Mounting holes for the Open Frame type of power supply.
Ⓐ
Mounting holes should be connected to the system's protective earthing (PE).
Ⓑ
This surface belongs to customer's end system or panel where the power supply is mounted.
Ⓒ
1) Note: 4 × Ø4 Mounting Holes; Ø7 Max Dimension of Screw Head and Stand-off. Recommended mounting torque for tightening: 4~8Kgf.cm.
• Please refer the table below for the recommended housing, terminal and AWG wire size.
Connector (Board Mounting)
CN1 Input (L, N, FG)
①
JST: B3P5-VH(LF)(SN)
②
CN2 Output (27V)
JST: B4P-VH(LF)(SN)
③
CN3 Output (12V)
JST: B2B-XH-A(LF)(SN)
4. Power Derating Curve (Refer to Fig. 4)
5. Input Voltage Derating Curve (Refer to Fig. 5)
• Output derating is required at 85-90Vac.
REV.01
Function
Line (L)
Neutral (N)
FG
-27V
-27V
+27V
+27V
+12V
-12V
1)
1)
Housing
Terminal
JST: VHR-5N
JST: SVH-21T-P1.1
JST: VHR-4N
JST: SVH-21T-P1.1
JST: XHP-2
JST: SXH-001T-P0.6
B
1
C
A
Fig. 1. Device Descriptions
A
CN1
Convection
> 50°C derate power by 2.5% / °C
AWG
100
22-18
90
22-18
80
70
28-22
60
50
40
30
20
10
0
-10
0
10
20
30
Surrounding Air Temperature (
Fig. 4. Power Derating Curve
TOP SIDE
D1
A
CN1
FRONT SIDE
2
3
B
CN1
Fig. 2. Assembly Reference
B
Fig. 3. Recommended Mounting Orientations
Convection
> 90Vac derate power by 2% / Vac
100
90
80
70
60
50
40
30
20
10
0
40
50
60
70
85
90
100
o
C)
Fig. 5. Input Voltage Derating Curve
PJT-27V150WBNA
PSU
D1
D1 = 8mm
PSU
D2* = 8mm
C
CN1
120
140
160
180
200
220
240
264
Input Voltage (Vac)