Download Print this page

Majestic Como vJUN19 Installation Manual page 4

Corner

Advertisement

Como Corner Installation Guide
Cover
Unscrew and separate the covers from the Wall Frame assemblies. You will also need to
3
separate the Cover from the Wall Frames used on the hinge side of the Door, as shown
above.
The Majestic Shower Company Limited
17 Flitch Industrial Estate, Chelmsford Road, Dunmow, CM6 1XJ
Inner wall profile
Outer wall profile
CHECK
Lay the glass Door horizontally on cushioned trestles or similar and assemble the
4
hinges to the glass Door as shown. Ensure that the clear plastic sleeves are fitted
inside the holes in the glass and that gaskets are placed either side of the glass.
Use the Wall Frame cover with hinge parts attached to check the spacing between
the hinges and use a set square to ensure that the hinges are correctly aligned.
Fully tighten the hinges. Leave for 10 minutes and then re-tighten to compensate
for compression of the gaskets.
Telephone +44 (0) 8448 001 500
Facsimile +44 (0) 1279 635 074 info@majesticshowers.com www.majesticshowers.com
4
CHECK

Advertisement

loading