1. HEALTH & SAFETY REGULATIONS The user manual contains instructions for the daily work with the equipment to be handled and used by the operator. The user manual must always be available to the operator(s) working with the equipment. It is important that: •...
3. WARNING DEVICES Annual inspection of warning devices and protective devices must be carried out. This refers to the control of their function and status. 3.1 Warning texts WARNING! Ignoring this information will result in immediate danger to life. PROHIBITED! Prohibited action associated with danger or death or serious injury! REQUIREMENT!
Page 7
Risk of falling NEVER climb, sit or stand on the platform railing. If the platform cannot be lowered, NEVER climb down the mast. Electricity This machine is not isolated against electric current. It is therefore necessary to have a correct safety distance to the high-voltage conductors or other current carrying objects.
Lock the swivel wheels when the lift is parked. Make sure that the working area around the lift is protected from people or other equipment. Never push or pull objects with the lift. Lock the lift when not in use to prevent unauthorized use. 4.
4.2 When rebuilding the lift If the lift is rebuilt or supplemented with other parts not approved by the manufacturer, this CE marking does not apply to the parts that change the function of the lift. Warning decals and CE marking on the lift must be clearly visible.
6. HOW TO USE All safety regulations, operating instructions, labels and national safety instructions / requirements must be carefully read, understood and complied with. 6.1 Checks before using the lift 1. Inspect the lift for any damage that may affect safety. 2.
emergency stop button to turn off the power. Rotate the emergency stop button clockwise to reactivate the power. 6.8 Emergency lowering (19) The lift is equipped with an emergency lowering system. Emergency lowering of the platform is done with a switch that is located on the lift chassis control panel.
7. MAINTENANCE 7.1 Inspection & maintenance intervals A complete inspection consists of periodic visual and functional checks along with minor adjustments in order to ensure the function. The daily inspection prevents the abnormal wear and prolongs the life of all machine systems. Inspection and maintenance will be performed at specified intervals.
7.3 Battery charging The lift’s batteries are located under the chassis control panel. The batteries are of AGM type, they are leak-proof and cannot be refilled with battery fluid. When batteries need to be replaced, this should only be done with batteries approved by the manufacturer. Battery acid is very corrosive.
7.4 Adjusting automatic wheel locking The lift is equipped with an automatic wheel lock (11). The wheel lock consists of a wire that is pressed down by an adjustable wire pusher. The wire pusher (9) is located under the platform floor, see picture below.
8. TECHNICAL DATA Total number of people on the platform ................ Maximum total platform load ................130 kg Maximum load on tool storage compartment 10 kg ............Lifting time (130 kg) ....................14.5 s Weight ........................236 kg Maximum wheel load .....................
Låglyftar i Sverige AB Kvarnvägen 14 SE-352 41 Växjö SWEDEN Låglyftar i Sverige AB, VAT-no: SE 556820966101, declares that the following products: PushAround PA35 Serial number: Year of manufacture: is manufactured in accordance with the following product directive: 2006/42/EC; 2014/30/EU; 2014/35/EC...