10. Initial operation

a) Quick installation with factory settings

The motion detector is immediately ready for operation with the factory default settings
described in section 7. The transmission signals are encrypted using a house code that is
randomly assigned when the batteries are inserted and the address group 11 (control of
several receivers with one transmitter possible).
For the initial operation of the transmission path to the receiver, the house code and the
addresses must first be transmitted to the receiver.
• Set the respective receiver, according to the instructions in its user manual, to the address
programming mode.
• Press the '2' button (channel 2: button '4') on the keypad of the 'FS20 PIRI-2'.
• The receiver's indicator LED goes out.
• Test the switch function by briefly pressing the '2' or '1' buttons (channel 2: button '4' or '3')
on the 'FS20 PIRI-2'. The receiver should switch on and off.
• Now the 'FS20 PIRI-2' is ready for operation with the factory settings.
• If you do not wish to set any further individual preferences, close the battery compartment.
• Place the device from below into the wall/ceiling bracket. It must audibly lock into place into
the wall/ceiling bracket.

b) Function test

You can adjust the detection area of the motion detector and thereby customise it for your
individual needs.
For this purpose, proceed as follows:
• Approach the detector by crossing back and forth across the detection area.
• When the detector detects you, it activates the status LED and the receiver.
• To individually optimise the detection area, the PIR motion detector can be adjusted when
in the wall/ceiling bracket.