HTV8EEMVP*1D
SENSOR RANGE ADJUSTMENT: (A)
The electronic sensor used in this cooler is factory pre-set for a "visual" range of 36 inches (914 mm). If
actual range varies greatly from this or a different setting is desired, follow the range adjustment procedure
below:
- Using a small tip screwdriver, locate range adjustment screw through the
small hole between the sensor lenses
increase range and counterclockwise to decrease range.
CAUTION: Complete range of sensor (24-46 inches/610-1168mm) is only one turn of the adjusting screw.
SENSOR CONTROL: If sensor fails to operate valve mechanism or operates erratically, check the following.
A. Ensure there are no obstructions within a 40 inch (1016mm) radius in front
of cooler.
B. Check wire connections at the solenoid valve and sensor.
CAUTION: Make sure unit is unplugged before checking any wiring.
C. Ensure proper operation of solenoid valve. If there is an audible clicking
sound yet no water flows,look for an obstruction in the valve itself or
elsewhere in the water supply line.