Page 3
HVR8FR*1B IMPORTANT ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON HANGER BRACKETS & TRAP INSTALLATION 1) Remove hanger bracket fastened to back of cooler by removing one (1) screw. 2) Mount the hanger bracket and trap as shown in Figure 2. NOTE: Hanger Bracket MUST be supported securely.
Page 5
HVR8FR*1B Fig. 5 Thermostat Installation Detail Fig. 6 Heater Strip Detail WARNING! ° This unit is frost resistant down to 0 F with no wind. Prevailing winds can reduce the ability of the heater element to prevent light freezing. If the ambient air °...
Page 6
HVR8FR*1B 115V PARTS LIST DESCRIPTION ITEM NO. PART NO. Gasket - Bubbler 56305C 100806740570 Grommet - Compressor Mtg. 101474551730 Stud - Compressor Mtg. Nipple - Bubbler 15009C 19037000 Clip - Compressor Mtg. Fan Blade 30664C 31490C Fan Motor 35839C Cold Control Cover - Relay 35768C 35900C...