LPG kit
2.1

Kit description

The kit allows the burners, to operate on LPG.
The kit is composed of:
Description
Gas distributor
Disc
Self-adhesive label
Instructions
2.2
Technical features
Model
Thermal power
Fuel
Minimum gas pressure
Maximum gas pressure
2.3
Conversion
Disconnect the electrical supply from the burner by
means of the main system switch.
DANGER
Close the fuel interception tap.
DANGER
Proceed as follows:
 On the combustion head: replace the gas distributor 1) with
that one supplied for LPG 2).
2915800
Quantity
MBtu/hr
358 - 1232
Commercial LPG GCV 26.47 kWh/Nm
"WC
measured on the coupling, with 0 "WC resistance in the combustion-chamber and gas
with gross calorific value of 2.55 MBtu/CU.FT.
"WC
LPG kit
Before starting the kit installation operations, get a
suitable lifting system ready.
1
1
Be careful as some drops of fuel may leak out dur-
1
ing the kit installation phase.
1
Tab. A
Apply the self-adhesive label near the burner data
plate.
WARNING
RS 28
437 - 1665
3
(C
H
= 93 - 94%) 2.55 MBtu/CU.FT.
3
8
8.7
2
GB
RS 38
549 - 1986
11.4
142
RS 50
14.2
Tab. B
D2510