3M 8825+ Technical Data Sheet
3M 8825+ Technical Data Sheet

3M 8825+ Technical Data Sheet

Particulate respirators

Advertisement

Quick Links

3M
Personal Safety Division | 3M
3M
Particulate Respirators
8825+ and 8835+
Technical Data Sheet

Description

The 3M
Particulate Respirators 8825+ and 8835+ meet the
requirements of European Standard EN 149:2001 + A1:2009,
filtering facepiece respirators for use against particles. They
provide effective respiratory protection for use in industries
where workers will be exposed to solid (dust) particles and/or
non-volatile liquid particles.

Applications

These respirators are suitable for use in concentrations of
solid (dust) particles and/or non-volatile liquid particles up to
the following limits:
EN 149:2001+A1:2009
Product
Classification
8825+
FFP2 R D
8835+
FFP3 R D
*Many countries apply Assigned Protection Factors (APFs)
which reduce the maximum concentrations of particles in
which these products can be used. See national regulations
and EN 529:2005.
Respiratory protection is only effective if it is correctly
selected, fitted and worn throughout the time when the
wearer is exposed to hazards.

Standards

Products are classified by filtering efficiency and maximum
total inward leakage performance (FFP1, FFP2 and FFP3), also
by usability and clogging resistance.
Performance tests in this standard include filter penetration;
extended exposure (loading) test; flammability; breathing
resistance and total inward leakage. Reusable products are
also subjected to cleaning, storage and mandatory clogging
resistance tests (clogging is optional for non-reusable
products). A full copy of EN 149:2001+A1:2009 can be
purchased from your national standards body.
Version: 1
This version is the sole document applicable to the product(s) since its date of publication
Particulate Respirators 8825+ and 8835+

Filter penetration

The filter penetration, initial and after 120mg of loading with
both 120mg of NaCl* and Paraffin Oil, shall not exceed the
following limits:
Maximum
EN 149:2001+A1:2009
Workplace Exposure
Classification
Limit (WEL)*
FFP2
12
FFP3
50
*Loading of NaCl may be stopped if filter penetration during
loading is observed to decrease.

Total inward leakage

Ten subjects perform five test exercises whilst wearing the
respirator. The total inward leakage inside of the respirator
due to face seal leakage, filter penetration and valve leakage
is measured for each subject exercise. The subject mean total
inward leakage for 8 out of 10 subjects shall not exceed the
following limits:
EN 149:2001+A1:2009
Classification
FFP2
FFP3
Maximum Filter Penetration
6%
1%
Maximum Total Inward
Leakage
8%
2%

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 8825+ and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for 3M 8825+

  • Page 1 Personal Safety Division | 3M Particulate Respirators 8825+ and 8835+ ™ ™ Particulate Respirators ™ 8825+ and 8835+ Technical Data Sheet Description The 3M Particulate Respirators 8825+ and 8835+ meet the ™ requirements of European Standard EN 149:2001 + A1:2009, filtering facepiece respirators for use against particles.
  • Page 2 Personal Safety Division | 3M Particulate Respirators 8825+ and 8835+ ™ ™ Breathing resistance Components and materials The breathing resistance of the respirator is tested during The following materials are used in the production of the inhalation (continuous flow) and exhalation (cyclical flow). The  Particulate Respirators 8825+ and 8835+:...
  • Page 3 Do not use in atmospheres containing less than 19.5% Ŕ Always be sure that the complete product is: oxygen. (3M definition. Individual countries may apply their own limits on oxygen deficiency. Seek advice if in doubt). – Suitable for the application;...
  • Page 4 Important Notice The use of the 3M product described within this document assumes that the user has previous experience of this type of product and that it will be used by a competent professional. Before any use of this product it is recommended to complete some trials to validate the performance of the product within its expected application.

This manual is also suitable for:

8835+

Table of Contents