  • Page 1 RAD-16LS Installation & Operation Manual Digitize, Inc. 158 Edison Road Lake Hopatcong, New Jersey 07849-2217 Tel: (973) 663-1011 Part Number: 700180-0000 E-mail: info@digitize-inc.com Revision: Website: http://www.digitize-inc.com Issue Date: 10/21...
  • Page 2 Digitize, Inc. 158 Edison Road Lake Hopatcong, NJ 07849-2217 The DIGITIZE logo is a registered trademark of Digitize, Inc.
  • Page 3 Website: http://www.digitize-inc.com This manual has been prepared by DIGITIZE, INC. for use by its licensees, distributors and customers. The information contained herein is the property of DIGITIZE, INC. and may not be copied, disclosed or reproduced, in whole or in part, without the prior written approval of DIGITIZE, INC.
  • Page 4 FCC NOTICE In compliance with Paragraph 15.105 of the FCC Rules and Regulations, the following notice is provided. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
  • Page 5: Table Of Contents

    P3 ..........................2-4 3 SYSTEM INITIALIZATION ................3-1 GENERAL ..........................3-1 ASSEMBLY .......................... 3-1 CONNECTIONS AND SETTINGS ..................3-1 3.3.1 ZONE INPUTS ......................3-1 3.3.2 ANTENNA ........................3-1 DIGITIZE, INC. 700180-0000 REV. E 10/21 Specifications Subject to Change Without Notice...
  • Page 6 POWER-UP.......................... 3-1 3.5.1 AC ..........................3-1 3.5.2 DC ..........................3-2 4 PROGRAMMING ....................4-1 PROGRAMMING AM BOX (RAD-16LS-AM)................ 4-1 4.1.1 PROGRAM FUNCTION SELECTION MODE .............. 4-1 4.1.2 SETTING BOX NUMBER (FUNCTION 1) ..............4-2 4.1.3 SETTING ZONE TONE ASSIGNMENT (FUNCTION 2) ..........4-2 4.1.4...
  • Page 7 RADIO TRANSMITTER TEST ..................... 6-1 7 MAINTENANCE ....................7-1 CIRCUIT BOARD REMOVAL AND REPLACEMENT ............7-1 8 APPENDIX A TONE FREQUENCIES ..............1 9 APPENDIX B TONE ASSIGNMENTS ..............1 DIGITIZE, INC. 700180-0000 REV. E 10/21 Specifications Subject to Change Without Notice...
  • Page 8 DIGITIZE, INC. 700180-0000 REV. E 10/21 Specifications Subject to Change Without Notice...
  • Page 9: General Information

    12.6 Vdc for battery backup. The battery is a 12 Amp Hour battery and will operate the RAD-16LS for a minimum of 75 hours during an AC failure. Slide switches and LEDs on the front panel allow the operator to view Alarm and trouble information and provide access to field programmable functions for the RAD- 16LS.
  • Page 10: Options

    ANTENNA The RAD-16LS may be configured for use with integral whip or external antennas. When the RAD-16LS is ordered with the integral whip antenna, the antenna is shipped inside the DIGITIZE, INC. 700180-0000 REV. E 10/21 Specifications Subject to Change Without Notice...
  • Page 11: Frequency

    High band P/N 450289-XXXX (132-174 MHz) 1.4.2 FREQUENCY Frequency selection will be accomplished prior to shipment of the unit. The operating frequency is designated by the last digits of the RAD-16LS part number (no decimals are used). Examples: RAD-16LS-XX-X-7278 Transmits at: 72.78 MHz RAD-16LS-XX-X-13895 Transmits at: 138.95 M...
  • Page 12: Fuses

    1.0 Watts (maximum) FCC REQUIREMENTS The RAD-16LS complies with the limits set for a Class B computing device as specified in Subpart J of Part 15 of The FCC Rules and Regulations. This unit also complies with Part 90 of The FCC Rules and Regulations.
  • Page 13: Applicable Publications

    RAD-16LS INSTALLATION AND USER MANUAL APPLICABLE PUBLICATIONS Federal Communications Commission “Rules and Regulations”, Parts 15 and 90. National Electric Code 1990 National Fire Protection Association Standards: 1221 DIGITIZE, INC. 700180-0000 REV. E 10/21 Specifications Subject to Change Without Notice...
  • Page 14 RAD-16LS INSTALLATION AND USER MANUAL DIGITIZE, INC. 700180-0000 REV. E 10/21 Specifications Subject to Change Without Notice...
  • Page 15: Installation

    Remove the four mounting screws from the front panel. Place the front panel and mounting screws in the shipping container. For initial installation, removal of the RF transmitter is not required. DIGITIZE, INC. 700180-0000 REV. E 10/21 Specifications Subject to Change Without Notice...
  • Page 16: Selecting Proper Box Mounting Location

    It is recommended that the desired location first be tested with a known working RAD-16LS box by holding the box in the desired location and sending a test transmission to the receiving location. If the signal strength is adequate at the receiving location, then the selected mounting location is good.
  • Page 17: Wiring

    RAD-16LS. Do not connect field wiring until the panel has been fully tested beforehand. Tag all wiring for later connection to the unit. Follow the procedures outlined in Section 3, System Initialization.
  • Page 18: Bs2

    RAD-16LS INSTALLATION AND USER MANUAL Table 2-1, Zone Input Terminal Label Terminal Label Terminal Label Terminal Label 2.6.2 Terminals 1 and 2 Label: AC POWER These terminals are connected to the secondary output of the AC transformer. Maximum input to these terminals is 18 Volts AC.
  • Page 19 RAD-16LS INSTALLATION AND USER MANUAL Figure 2-1, Inter-equipment Wiring Diagram DIGITIZE, INC. 700180-0000 REV. E 10/21 Specifications Subject to Change Without Notice...
  • Page 20 RAD-16LS INSTALLATION AND USER MANUAL DIGITIZE, INC. 700180-0000 REV. E 10/21 Specifications Subject to Change Without Notice...
  • Page 21: System Initialization

    3 SYSTEM INITIALIZATION GENERAL For initial set-up of the RAD-16LS, the following instructions should be carried out in the order in which they appear. However, if during the operation of the unit it should become necessary to set the time on the internal clock this can be done without going through the power-up sequence.
  • Page 22 RAD-16LS INSTALLATION AND USER MANUAL 3.5.2 Connect the factory-supplied battery cable to the battery. It is important to carefully observe polarity when connecting the battery cable, (RED = positive, BLACK = negative). DIGITIZE, INC. 700180-0000 REV. E 10/21 Specifications Subject to Change Without Notice...
  • Page 23: Programming

    4 PROGRAMMING The RAD-16LS is fully field programmable. No special programming tools are required. The programming information for the RAD-16LS is stored in an Electrically Erasable Prom. The information stored on this chip is retained even in the event of loss of power.
  • Page 24: Setting Box Number (Function 1)

    RAD-16LS INSTALLATION AND USER MANUAL To program a function once it has been selected, press the “TEST” button (SW1 through SW8 must be in the down position). The RAD will beep once. The “BATTERY FAULT” LED will go “OFF” and the “WATCHDOG” LED will come “ON.” The box is now in the programming sequence for the selected function.
  • Page 25: Panel Options 1 (Function 3)

    After programming all 16 zones, press “TEST” to save all tones and return to function selection mode. Function 2 is not used if the Digitize 99 Zone or King Fisher IRAC radio format are selected. Function 2 pertains to the Eagle Signal or King Fisher Radio Format only.
  • Page 26: Panel Options 2 (Function 4)

    RAD-16LS INSTALLATION AND USER MANUAL number to the minute setting for the next Test transmission time (Function 8). For example: If the box number was 123 and the next scheduled Test transmit time was 01:00:00, then the AC failure would be reported 23 + 00 = 23 minutes after the failure.
  • Page 27: Radio Box Format (Function 5)

    SW7 sets the number of zones that can be transmitted together in a radio transmission. The Digitize 99 zone format allows up to five zone to be transmitted per radio transmission. Placing SW7 in the Up position will allow five zones to be sent at one time.
  • Page 28: Setting Tilt/Tamper Sensitivity (Function 6)

    RAD-16LS INSTALLATION AND USER MANUAL King Fisher IRAC with Programmable Zones – AC Power, Tamper and Test signals can be programmed to any ton assignment. 4.1.7 SETTING TILT/TAMPER SENSITIVITY (FUNCTION 6) Enter the Program Function Selection mode. Press SILENCE until the red LED for Zone 6 illuminates to indicate Function 6 is selected.
  • Page 29 RAD-16LS INSTALLATION AND USER MANUAL Table 4-5, Switch settings for Hours TIME Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down...
  • Page 30: Setting Time Interval Between Test Transmissions

    RAD-16LS INSTALLATION AND USER MANUAL Table 4-6, Switch Settings Minutes (High Digit) TIME Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down Down Table 4-7, Switch Settings Minutes (Low Digit) TIME Down Down...
  • Page 31: Zone Input Settle Time (Function 10)

    RAD-16LS INSTALLATION AND USER MANUAL Use SW1 through SW8 to enter the current hour’s digits. As per Table 4.5, hours must be entered in military time. Time is entered in packed binary format (BCD). Press “SILENCE” to save hours. If an invalid time is entered, the panel will beep twice to indicate an error. If the entry was acceptable, the panel will beep once to acknowledge.
  • Page 32: Preset Option Memory (Function 13)

    RAD-16LS INSTALLATION AND USER MANUAL Enter the Program Function Selection mode. Press SILENCE until the yellow LED for Zones 12 illuminates to indicate Function 12 is selected. Press TEST. The alarm LED for Zone 1 will be flash. Using SW1 - SW8, select the desired delay period for Zone 1. All switches down indicates 0 second delay, all switches up indicates 90 second delay.
  • Page 33 RAD-16LS INSTALLATION AND USER MANUAL (Tone Assignment, Zone 8) (Tones 7, 8) (Tone Assignment, Zone 9) (Tones 0, 9) (Tone Assignment, Zone 10) (Tones 1, 9) (Tone Assignment, Zone 11) (Tones 2, 9) (Tone Assignment, Zone 12) (Tones 3, 9)
  • Page 34: Quick Program Daily Test

    VIEWING CURRENT AM BOX SETTINGS Place RAD-16LS into the Program Function Selection Mode. To do this, place SW1 through SW8 in the down position. Press and hold the “SILENCE” button. While holding the “SILENCE”...
  • Page 35: View Panel Options 2 (Function 4)

    RAD-16LS INSTALLATION AND USER MANUAL 4.2.4 VIEW PANEL OPTIONS 2 (FUNCTION 4) Place RAD into the Program Function Selection Mode and select Function 4. The red alarm LEDs show option 2 settings. (An illuminated yellow LED simply indicates that particular switch is in the UP position.) Press “TEST”...
  • Page 36: View Zone Delays (Function 12)

    RAD-16LS INSTALLATION AND USER MANUAL 4.2.12 VIEW ZONE DELAYS (FUNCTION 12) Place RAD into the Program Function Selection Mode and select Function 12. The red alarm LED for Zone 1 illuminates indicating the Zone Delay for Zone 1. The yellow trouble LEDs indicate the current value in binary form.
  • Page 37: Theory Of Operation

    5 THEORY OF OPERATION ALARM INPUT The RAD-16LS contains sixteen separate alarm input channels. Each zone has a single bi- color led that can light either red for Alarm or yellow for Trouble. MICROPROCESSOR The RAD-16LS is a microprocessor based unit and contains a reusable EPROM to store the program and operating data.
  • Page 38: Controls

    “ANT”. 5.5.2 The FM transmitter is crystal controlled and frequency modulated. The FM transmitter plugs directly into the main board of the RAD-16LS. The antenna is plugged into the transmitter using the connector marked “ANT”. CONTROLS 5.6.1...
  • Page 39: Ac Power

    BYPASS - If a zone is bypassed, the associated LED for that zone will flash yellow. GROUND FAULT - If the RAD-16LS detects a Ground Fault on zone inputs, all of the zone LEDs will flash yellow.
  • Page 40: Standby Power Operation

    Standby Power Operation is also indicated by a flashing POWER LED. When a low battery condition is detected, the RAD-16LS will transmit this to the receiving console during a daily test transmission or whenever a radio transmission is made (determined by the radio format selected).
  • Page 41: Testing

    Using the table below, test all alarm and trouble initiating devices for each zone. Test each zone bypass switch by pushing switch to the “BYPASS” position and actuate an alarm. If working properly, the LED should light red indicating an alarm but the RAD-16LS should not transmit the alarm.
  • Page 42 RAD-16LS INSTALLATION AND USER MANUAL Hold down the “CLEAR/SILENCE” and “TEST” buttons simultaneously then press and release the “RESET” button. If the jumper is inserted correctly, the “COMM LINK” LED and all of the alarm LEDs will illuminate. The radio transmitter is now transmitting carrier.
  • Page 43: Maintenance

    7. Replace screw fastener on right side of box. 8. Connect antenna cable from transmitter. 9. Connect the interface plug to connector P1. 10. Test all functions of unit. DIGITIZE, INC. 700180-0000 REV. E 10/21 Specifications Subject to Change Without Notice...
  • Page 44 RAD-16LS INSTALLATION AND USER MANUAL DIGITIZE, INC. 700180-0000 REV. E 10/21 Specifications Subject to Change Without Notice...
  • Page 45: Appendix Atone Frequencies

    8 APPENDIX A TONE FREQUENCIES TONE FREQUENCIES TONE FREQUENCY (Hz) DIGITIZE, INC. 700180-0000 REV. E 10/21 Specifications Subject to Change Without Notice...
  • Page 46 RAD-16LS INSTALLATION AND USER MANUAL DIGITIZE, INC. 700180-0000 REV. E 10/21 Specifications Subject to Change Without Notice...
  • Page 47 EAGLE SIGNAL/KING FISHER RADIO FORMATS ZONE ASSIGNMENTS FOR TWO FUNCTION TONES ZONE FUNCTION FUNCTION TONE 1 TONE 2 ZONE ASSIGNMENT FOR ONE FUNCTION TONE ZONE FUNCTION TONE 1 DIGITIZE, INC. 700180-0000 REV. E 10/21 Specifications Subject to Change Without Notice...
  • Page 48 RAD-16LS INSTALLATION AND USER MANUAL DIGITIZE, INC. 700180-0000 REV. E 10/21 Specifications Subject to Change Without Notice...
  • Page 49 Digitizes products by salesmen, dealers, distributors or agents, unless confirmed in writing by a Digitize officer. If the firmware or hardware is altered or modified by the Buyer, this firmware and hardware is not covered within this limited warranty and the Buyer bears sole responsibility and liability for that firmware and hardware.