Table of contents Table of contents Safety instructions and warnings ........5 General ..................5 1.1.1 Definitions ................. 5 1.1.2 Symbol explanation ..............6 Intended use ................7 Foreseeable misuse ..............7 Tanning safety information ............8 1.4.1 Prohibited usage ............... 8 1.4.2 Important notes ................
Safety instructions and warnings Safety instructions and warnings To ensure safe operation of the device, it is necessary to read the following safety instructions and warnings carefully and comply with them. These instructions should be retained for future use. The safety instructions summarized here are repeated in the corre- sponding chapters, where necessary.
Safety instructions and warnings 1.1.2 Symbol explanation The following types of safety notices are employed in these operating instructions: DANGER! Type and source of hazard This safety notice indicates the existence of a direct danger to body and life. DANGER! Type and source of hazard This safety notice warns of dangers to body and life which are caused by electricity.
Safety instructions and warnings Intended use This unit serves the purpose of cosmetic tanning for one adult person with skin suitable for tanning. More detailed information can also be found on pages 11 and 36. Some people are not permitted to use the unit, see Section '1.4.1 Prohibited usage'.
Safety instructions and warnings Tanning safety information 1.4.1 Prohibited usage DANGER! UV radiation Danger of skin and eye injuries or skin diseases! – Please observe the following instructions. The following people may not use the device: People under 18 years of age ...
Safety instructions and warnings The following people may only use the device after consultation with their doctor: People with chronic illnesses, in particular those related to the skin People with illnesses of the immune system / auto-immune dis- eases People with collagenosis (e.
Page 10
Safety instructions and warnings Protect sensitive skin areas such as scars, tattoos and genitals before tanning. Observe the recommended tanning times. During a tanning session the quantity of radiation which results in the skin reddening (MED, minimum erythema dose) may not be exceeded.
Safety instructions and warnings 1.4.3 Skin type descriptions DANGER! Burns and long-term damage! People with skin type I may not use the tanning device. The following applies to people with skin types II, III and IV: – Observe the tanning times. –...
The maximum tanning time must not exceed 33. The tanning sessions must be at least 48 hours apart. The maximum tanning minutes per year should not exceed 833 minutes. DAYON LightSpa Soft: Low-pressure lamps LightSpa CARE by Ergoline R 120 W C 30 1514074-..
Page 13
Safety instructions and warnings DAYON LightSpa Beauty: Low-pressure lamps LightSpa BEAUTY by Ergoline R 120 W 1515514-.. Low-pressure lamps LightSpa BEAUTY by Ergoline R 100 W 1515513-.. Low-pressure lamps LightSpa BEAUTY by Ergoline R 120 W 1515515-.. Number of tanning Skin type I Skin type II...
Safety instructions and warnings Safety instructions and warnings 1.5.1 Operator's obligations As the operator you are responsible for providing clear operating, cleaning and maintenance instructions and ensuring the intended use and the proper operation of the unit by means of training and instruc- tion for the personnel.
Safety instructions and warnings 1.5.4 Transport, assembly and setup The unit is delivered by a specialist company and assembled and set up by an authorised service company. Assembly DANGER! Personal danger due to electric shock or burns! – The electrical connection must comply with na- tional regulations.
Page 16
Safety instructions and warnings Setup location WARNING! Salty air! Contaminated air! Device damage due to corrosion of the housing and electrical components. – Do not set up the unit at a swimming pool. – Do not operate the device in locations with ag- gressive environmental conditions (e.g.
Safety instructions and warnings 1.5.5 Commissioning DANGER! Damaged mains power cable! Danger to persons due to electric shock and risk of burns. – The unit must not be used if the mains power ca- ble is damaged. NOTE! The process for replacing the mains power cable is described in Section 2 and 2.2.
Safety instructions and warnings 1.5.7 Decommissioning The mains plug must be disconnected in order to temporarily or per- manently decommission it. The legal requirements regarding disposal must be observed when permanently decommissioning the unit. 1.5.8 Storage Store the devices in a dry location with a stable temperature. Once the device has cooled off, pack it in plastic wrapping to protect it against scratches.
Germany and accept all obligations in respect of the German Electrical and Electronic Equipment Act. Registry number JK-International GmbH, division JK-Licht GmbH (lamps): WEEE-DE 61515020 Registry number JK-Products GmbH (Devices): WEEE-DE 62655951 1.5.10 EU guidelines See the included EC Declaration of Conformity.
Safety instructions and warnings Signs and stickers on the unit Danger area warning signs and important information about compo- nents are attached to the unit. The signs shown below are examples. Ensure that the warning signs are always clearly recognisable and leg- ible.
Page 21
Safety instructions and warnings 2: Lamp set sticker The precise details of the required lamps are available in the separate appendix. 3: Type plate The name plate is attached to the back of the base. It contains im- portant information for identifying the unit (e.g. the serial number = Serial-No.).
Safety instructions and warnings Preclusion of damage Insofar as the customer asserts any rights related to a defect in the unit based on the legal warranty and/or guarantee, the following shall apply: The warranty and guarantee do not cover wear parts such as low-pressure lamps (tubes) or consumables (aroma) or acrylic glass panels.
Safety instructions and warnings Exclusion of liability Regardless of the legal grounds, liability of the JK Group shall be ex- cluded if damage can be attributed to one or more of the following causes: improper use of the unit; improper assembly, commissioning, operation and maintenance ...
Dismantling/Setup/Commissioning Dismantling/Setup/Commissioning Two people are needed to dismantle and set up the unit. NOTE: In the event of damage, JK-International GmbH shall assume no liability if the damage is caused by im- proper setup! Please read these instructions carefully before setup and follow all the steps. Setup tools needed: 4 mm hex socket (included in the scope of delivery) ...
Dismantling/Setup/Commissioning Dismantling the canopy WARNING! Danger of hand injuries! – Wear protective gloves during assembly work to avoid injuries. NOTE: The unit may need to be dismantled in order to move it to its intended location. The unit should always be dismantled due to its weight and for handling reasons.
Page 26
Dismantling/Setup/Commissioning – The canopy must be held up by a second person. NOTE! Only gently prop the canopy otherwise it may tip back. DANGER! Risk of injury due to mechanical forces! – Always remove the splint and pin when open! Remove the gas pressure absorber –...
Page 27
Dismantling/Setup/Commissioning NOTE: Place a scratch guard between the canopy and base to avoid damage to the unit. – Close the canopy. NOTE: Prepare a clean, soft surface before lifting the canopy. Dimensions: approx.: 1200 mm x 2200 mm (e.g.: unit’s cardboard packaging). –...
Dismantling/Setup/Commissioning This step must be performed by two people! – Lift up the closed canopy and carefully move it to one side onto a clean, soft surface. NOTE: Prepare a clean, soft surface before lifting the canopy. Dimensions: approx.: 1200 mm x 2200 mm (e.g.: unit’s cardboard packaging).
Page 29
Dismantling/Setup/Commissioning This step must be performed by two people! – Carefully place the canopy’s sickle into the mount- ings on the base. – Tighten the three screws on each one. Tool: 4 mm Allen key – Put on the safety cap. –...
Page 30
Dismantling/Setup/Commissioning Install the gas pressure absorber – Place the gas pressure absorber into the mounts. NOTE: The gas pressure absorber’s oil tank must always point upwards. – Place the pin through the clevis. – Fold in the safety splint. – Remove the scratch guard.
Page 31
Dismantling/Setup/Commissioning – Insert the mains connector so that it clicks into place. – Insert the Schuko connector into the socket. NOTE: Make sure that the mains plug is always accessible so that the unit can be disconnected from the mains plug.
Page 32
Dismantling/Setup/Commissioning – Insert the AROMA card into the side opening on the fan. NOTE: The films on the acrylic panels must always be re- moved to ensure that the lamps can work safely. The films on the panels must also be removed straight away to avoid paint damage.
Description Description Scope of delivery Tanning device Allen key UV protective goggles Low pressure lamps Technical documentation AROMA card Equipment The equipment of the units differs depending on the model. In this description, all standard and optional components/functions are taken into account which must be observed during operation and/or when performing maintenance.
Description Unit description 1. SPECTRA LEDs (depending on the equipment) 2. Control panel 3. Low-pressure lamps, canopy 4. Handle, canopy 5. Low-pressure lamps, base 6. Body cooling with AROMA 7. On/off switch (on the back of the unit) 34/70...
Description Functional description The primary technical components of a solarium are an artificial source of UV radiation and a mechanical structure with a defined ac- tive surface. DAYON LightSpa is a treat for your skin, using a combination of tan- ning UV light and the gentle Beauty light.
Operation Operation User safety information DANGER! UV radiation Danger of skin and eye injuries or skin diseases! – Please observe the safety instructions and warn- ings in chapter 1. Tanning - but correctly! A few things need to be noted in order to obtain maximum enjoyment from a tanning unit.
Page 37
Operation Contact lenses on the sunbed? The answer is: Yes! Like any other tanning unit user, contact lens wearers should also wear special protective goggles which protect the eyes against UV radiation. To guarantee better protection, wearers of spectacles and contact lenses can ask their optician for exchange contact lenses with UV protection.
Operation 4.4.1 Navigation Icon selection / Description/display Information Key sequence PLUS button Pressing this button changes the time setting. Pressing this button changes the time MINUS button setting. Time setting In standby mode, press the plus or minus button to change the time. Pressing and holding the plus or minus button for 2 seconds makes the minutes go up or down faster.
Operation 4.4.2 Info / Maintenance / Button lock Icon selection / Description/display Information Key sequence 10 seconds after the last button is pressed, the unit automatically Press and hold for 3 seconds. switches to standby mode; the current settings are adopted. press Resetting the lamp runtime after replacing a lamp:...
Operation Start – Close the canopy. – Press the START/STOP button. Upon starting the following functions are activated: Lamps and SPECTRA LEDs Body cooling 42/70...
Cleaning and maintenance Cleaning and maintenance Safety instructions when under- taking cleaning or maintenance work DANGER! Electricity is present throughout the entire unit! Danger to persons due to electric shock and risk of burns. – Disconnect the mains plug before performing any work on the unit! Faults If the INTERIOR DISPLAY does not show 00:00 within 5 seconds:...
Cleaning and maintenance 5.3.1 Disinfection We recommend DAYON rapid disinfectant as a cleaning agent for rapid and thorough disinfection: It is recommended for use on the sen- sitive acrylic surface, it is 100% organic and extra kind to the skin (Der- matest: Very good).
Cleaning and maintenance Plastic surfaces To clean the painted and unpainted plastic surfaces, it is best to simply use warm water and a leather cloth. Never use alcohol-based aggressive cleaning agents or essential oils. These may lead, in the long term, to damages not covered by the warranty. Prevent damage to the acrylic glass and plastic surfaces.
Cleaning and maintenance Maintenance Maintenance and care play a major role in deciding whether the unit meets the requirements placed on it in a satisfactory manner. Compli- ance with the specified maintenance intervals and thorough mainte- nance and care are therefore absolutely essential. For commercial use, we would like to point out that the unit must be subjected to regular inspections by our customer service or an ap- proved specialized company every 12 months (from commissioning)
Cleaning and maintenance Maintenance schedule for wear parts WARNING! Only use genuine spare parts of the same type! If other parts are used then the device no longer com- plies with the conformity declaration and may not be operated any longer! Any liability for damage or injury proven to be the re- sult of the use of non-genuine spare parts is excluded.
Page 49
Cleaning and maintenance Maintenance by authorised, trained and qualified personnel for the operator or private user: CAUTION! Danger to people due to maintenance work not car- ried out! If the maintenance work is not carried out, material damage and personal injury may occur! –...
Cleaning and maintenance Disassembly for maintenance and cleaning work 5.7.1 Removing the canopy panel NOTE: The base panel must be closed before the canopy panel is dismantled – Release and unscrew the five screws. NOTE: Remove the outside screws first and then remove the screws in the middle.
Cleaning and maintenance – Remove the canopy panel with the aid of a helper. The assembly is the same process in reverse order. When assembling please note: – Use the scratch protection. – Carefully lay the canopy panel in the guide. –...
Page 52
Cleaning and maintenance – Push the base panel to the rear with one hand and pull it out of the front guide. – With a second person to help you, remove the base panel and carefully place to one side. The assembly is the same process in reverse order.
Cleaning and maintenance Instructions for replacing the lamps DANGER! Danger of burns from hot lamps and surfaces! Finger and hands may get burned when replacing lamps. – Before carrying out maintenance work, wait until the device has cooled down sufficiently. NOTE: Small quantities of mercury can escape if the bulb/lamp glass breaks! Please comply with the fol-...
Cleaning and maintenance 5.8.1 Low-pressure lamps Replace faulty low-pressure lamps immediately. Always replace the entire set of lamps after the specified operat- ing time. – Turn 90° and carefully remove from the socket. – Low-pressure lamps possess a reflector which directs the light outwards.
Cleaning and maintenance Cleaning or replacing lamps in the base See Section 'Removing the acrylic glass panel', page 51. Replacing lamps: see page 54. 5.10 Cleaning or replacing lamps in the canopy Removing the canopy panel: see page 50. Replacing the lamps: Low-pressure lamps: see page 54.
Technical data Technical data Power, connection rating and noise level DAYON Power consumption rating: 3000 W Rated frequency: 50 Hz Rated voltage: 230 V ~1 Rated fuses: 1 x B16A Connection type: for DE/NL/AT: Earthed plug (Type F) Connection type: for CH: Hexagonal plug with 3 round contacts arranged in a triangular pattern (type 23) Load on the acrylic glass panel:...
The operating licence is invalidated if other lamps are used. Moreover lamps must be marked with a matching equivalence key, see attachment page 64. 6.3.1 DAYON LightSpa Soft Lamp set (UV type 3) Number Description Length Power Control Order-no.
Technical data 6.3.2 DAYON LightSpa Intense Lamp set (UV type 3) Number Description Length Power Control Order-no. Low-pressure lamps 1,80 m 100 W 100 W 1514034-.. LightSpa SUN by Ergoline R 100 W S 35 Low-pressure lamps 1,80 m 120 W 120 W 1514033-..
Technical data 6.3.3 DAYON LightSpa Hybrid Lamp set (UV type 3) Number Description Length Power Control Order-no. Low-pressure lamps 1,80 m 100 W 100 W 1514034-.. LightSpa SUN by Ergoline R 100 W S 35 Low-pressure lamps 1,80 m 120 W 120 W 1514033-..
Technical data 6.3.4 DAYON LightSpa Beauty Lamp set (UV type 3) Number Description Length Power Control Order-no. 1515513-.. Low-pressure lamps 1,80 m 100 W 100 W LightSpa BEAUTY by Ergoline R 100 W 1515514-.. Low-pressure lamps 1,80 m 120 W 120 W LightSpa BEAUTY by Ergoline R 120 W Low-pressure lamps...
Technical data Spare parts, wear parts and accessories Number Description Order-no. Scent card 1514150-.. Canopy panel 1514013-.. Base panel 1514018-.. Gas pressure spring 1513924-.. Mains power cable 1503304-.. with Type F safety plug Mains power cable 1027142-.. with Type 23 safety plug SW4 Allen key with T-handle 84500-..
Appendix Appendix Equivalence key range Example for calculating the equivalence key range (1), see the lamp configuration sticker: If the equivalence key of the lamp with which the device has been equipped during the type approval is 100–R–47/3.2, the equivalence key range with which the device should be marked is calculated as follows: Bottom value of the X section: 0.75 x 47 = 35.25 Bottom value of the Y section: 0.85 x 3.2 = 2.72...
Appendix 7.1.1 Description of the equivalence keys for fluorescent lamps The equivalence key for fluorescent lamps for tanning that is repre- sented in detail in the IEC 61228 and that is marked on the lamp in a readable and permanent manner, is described in the following. The equivalence key has the following structure: Wattage –...
Need help?
Do you have a question about the DAYON LightSpa Soft and is the answer not in the manual?
Questions and answers