NOTE / Drain hose or tubing can be purchased locally to satisfy
your particular needs.
4. Slide the chassis back into the cabinet. Reinstall the cabinet to
the chassis by using screws.
8.6. Electric Work
- Always use at the rated voltage and with a specific air conditioning
circuit.
- Some installation locations may require the installation of a short-
circuit breaker.
- A 16 Ampere time delay fuse or circuit breaker is required.
- Nominal cross sectional area of power supply wire must be 3 core
x 1.0 mm
or above.
2
- The power supply must be from an independent circuit.
- All electrical installations must be made in accordance with local
wiring and safety regulations wherever applicable.
- There must be a double pole switch with a minimum of 3 mm
contact gap in the fixed installation circuit.
- Please engage an authorized dealer or specialist for the
installation work.
8.7. Noise Consideration
- Select an installation location that can support the weight of the air
conditioner and one that will not cause increased operating noise
and vibration.
- Ensure that airflow and noise from the rear side of the unit

Advertisement