9. TECHNICAL DATA

Manufacturer
Address
Power supply
Operational voltage
Overall power consumption
General
Protection class
Ambient temperature for during operation
Ambient temperature for storage
Dimensions
Weight
Material
Actuating force
enabling button
Actuating force
additional buttons
Mechanical /electrical durability of
enabling button
Mechanical reliability B
10D,
enabling button
Mechanical /electrical durability of
emergency stop button
Mechanical reliability B
10d,
emergency stop button
Mechanical durability of
additional button 1
Mechanical durability of
additional buttons 2/3/4
Connection
ABB Electrification Sweden AB
SE-721 61 Västerås, Sweden
30 VDC, AS-i Bus, tolerance 26 - 31,6 VDC
<150 mA
IP65
-10°C
up to +55°
(no buildup of ice)
-20°C
up to
(no buildup of ice)
+70°
C (no direct sunlight)
See drawing in section 12 "dimensions"
approx. 200 g without connection cable
Housing: Fiberglass reinforced plastic, PPH G30
Operating buttons: TPE
approx. 20 N, 1  2
approx. 45 N, 2  3
approx. 3 N, additional buttons 1 and 2
approx. 7 N, additional buttons 3 and 4
switching cycles, position 1  position 2
6
1 x 10
5
switching cycles, position 2  position 3
1 x 10
6
, position 1  position 2  position 1
B
: 2 x 10
10D
: 968,000, position 1  position 3  position 1
B
10D
4
5 x 10
switching cycles
B
: 250,000
10D
6
2 x 10
switching cycles
4
5 x 10
switching cycles
M12 connector 5 pin, A coded