5.7.2 Connecting Cables to Amphenol Helios H4 Connectors

Specification Requirements
Cables with high rigidity, such as armored cables, are not recommended, because
poor contact may be caused by the bending of cables.
Use the Amphenol Helios H4 connectors delivered with the solar inverter. If the PV
connectors are lost or damaged, purchase the connectors of the same model. The
device damage caused by incompatible PV connectors is beyond the warranty
scope.
Procedure
Step 1 Prepare the DC input power cables.
Step 2 Crimp positive and negative metal contacts.
Step 3 Insert the contacts into the corresponding positive and negative connectors.
Issue 15 (2023-01-31)
Terminal Selection
PV2, PV6, PV10, PV14, and
PV18
PV2, PV4, PV6, PV10, PV14,
PV18, and PV20
PV2, PV4, PV6, PV8, PV10,
PV14, PV16, PV18, and
PV20
PV1, PV2, PV4, PV6, PV8,
PV10, PV12, PV14, PV16,
PV18, and PV20
PV1–PV4, PV6, PV8, PV10,
PV12, PV14, PV16, and
PV18–PV20
PV1–PV6, PV8, PV10, PV12,
PV14, and PV16–PV20
PV1–PV8, PV10, PV12, and
PV14–PV20
PV1–PV10 and PV12–PV20
CA UTION
Copyright © Huawei Technologies Co., Ltd.
5 Electrical Connections
Number
Terminal Selection
of PV
Strings
6
PV2, PV4, PV6, PV10, PV14,
and PV18
8
PV2, PV4, PV6, PV8, PV10,
PV14, PV18, and PV20
10
PV2, PV4, PV6, PV8, PV10,
PV12, PV14, PV16, PV18,
and PV20
12
PV1, PV2, PV4, PV6, PV8,
PV10, PV12, PV14, PV16,
and PV18–PV20
14
PV1–PV4, PV6, PV8, PV10,
PV12, PV14, and PV16–
PV20
16
PV1–PV6, PV8, PV10, PV12,
and PV14–PV20
18
PV1–PV8, PV10, and PV12–
PV20
N/A