Download Print this page

Majestic Portofino Installation Manual page 9

17- or 24-mm surface wall profiles
Hide thumbs Also See for Portofino:

Advertisement

Portofino Installation Guide
Underframe Insert
width = Door width
+ 10mm
Using suction glass lifters, lift the In Line and Return
9
panels into their respective wall profiles and carefully
lower into the underframe channel. Ensure that the
Return panel is pulled forward in the underframe to
align as shown.
Make sure that the gap for the door is the correct
width (width of door + 10 mm) and that the under-
frame Insert fits snugly between the glass panels.
Disassemble the Glass to Wall brackets being careful
11
not to damage the face plates. With the clear plastic
gaskets inserted between the brackets and the glass
and the wall screw plates facing inwards, align all four
brackets centrally in the slots in the glass, hold them
in place and mark the screw hole positions.
Mark both wall profiles at the top edge of the glass so
that they can be trimmed flush.
The Majestic Shower Company Limited
17 Flitch Industrial Estate, Chelmsford Road,
Dunmow, CM6 1XJ
Check that the front edges of the In Line and Return
10
panels are plumb vertical and level with one another,
using additional rubber strips under the glass if
necessary and noting the position of these strips.
Do not use more than 3 thicknesses of rubber under
each panel of glass.
Use the suction glass lifters to remove the Return
12
panel, making a note of the number and position of the
rubber strips that you have placed under the panel.
Unscrew and remove the wall profiles.
Drill 7mm holes for the wall brackets in the positions
marked and insert the wall plugs. Apply a small amount
of silicone around the holes in the wall to prevent any
water from leaking into the wall.
Telephone (0) 1279 443644
info@majesticshowers.com
www.majesticshowers.com
Page 7

Advertisement

loading