Page 2
You can contact us at: Berghof Automation GmbH Arbachtalstrasse 26 72800 Eningen Germany T +49.7121.894-0 F +49.7121.894-100 Email: controls@berghof.com www.berghof-automation.com Berghof Automation GmbH is certified to DIN EN ISO 9001:2015. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
Page 3
New graphics, corrections 13/11/2018 Corrections and additions 03/12/2018 Review 04/12/2018 Initial version 07/05/2020 Conversion to S-number system 18/06/2020 Formatting revised in the document 19/09/2022 Cyber security added Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
Individual instruction or list of instructions which can be carried out in any order. … List of instructions which must be carried out in the order given. … Additional product information Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
Failure to observe the safety measures may result in minor injuries. ► Take preventive measures. NOTICE Possible damage to property Failure to observe the safety measures may result in damage to property. ► Take preventive measures. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
→ The user is responsible for coordinating the use of the safety-related control components with the responsible authority and for adhering to its specifications. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
The device is intended for installation in a suitable installation cut-out in industrial machines and systems in indoor areas. ► During installation, make sure that the existing seal profiles are undamaged. For operation, refer to the applicable ambient conditions (see “Technical data”). Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
► If you notice any damage in transport or the contents do not match the order: inform the suppliers immediately. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
2.2.1.3 Password configuration The passwords assigned by Berghof must be changed by you during the initial commissioning. You can make this change via the web menu, where you will also find the users created by Berghof (see chapter 7.1). 2.2.1.4 Cybersecurity These controllers must not be connected directly to the Internet without external protection through suitable firewalls.
USER MANUAL 1.2 | B-FORTIS CC-LITE SERIES 3 Product description The devices from the B-Fortis CC-Lite series are compact COESYS high performance controllers combining the functions of several individual components in one device. This enables high functional reliability, fast data communication and simple project planning and programming.
IT infrastructure. Optional field buses (Ethercat; Modbus-TCP/IP, etc.) can also be used. When using field bus, programming via an ETHERNET to USB adapter is recommended. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
Program and data memory (RAM) 256 MB onboard → Program memory (flash): up to 2 GB onboard → 1 USB host interface (USB 2.0) → 1 Ethernet 10/100 Base T interface Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
Guide the device from above towards the mounting rail and gently hold the spring pressed in. Push the device at the bottom towards the mounting wall and snap into place. The device is clamped on the mounting rail. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
All connections and cables should be set up in a way that prevents interference and capacitive interference to the device. ► Make sure that the current and voltage resistance of the supply cables are sufficient. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
Meaning according to IEEE 802.3 clause 25 LNK/RCV Green Link, Data Receive Flashing: connection active; data transfer in progress Off: no connection established SPEED Yellow On = 100 Mbit/s Off = 10 Mbit/s Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
This can result in considerable damage to property and damage to the USB device. ► Before using a USB device, check its power consumption. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
The functional earth is connected via a cable with 6.3 x 0.8 blade receptacles on the rear of the unit. Fig. 6: Connecting the earth via a cable with blade receptacles Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
The device does not have an on/off switch. The device starts automatically when the system is switched on or the power is connected. 6.1.1.2 Switching off The device is switched off when the system is switched off or the power supply is disconnected. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
The login window is displayed. Fig. 7: Login window Log in with the following login information: Name: admin Password: admin The web configuration page will be displayed. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
Page 23
Click on “Reboot” in the web interface and then confirm on the next page by clicking on “Reboot Module”. The device is configured and ready for use. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
During the boot process, the device does not give any warnings via the LEDs. Settings are made via the web interface. Further information on operating and setting up the controller can be found in the Berghof IMX Control Platform SYSTEM MANUAL in CODESYS V3.
Fig. 11: “Network Configuration” page Open file “usbupdate.ini” with a text editor that supports the Linux text format (e.g. Notepad++ or Ultraedit). Search for section [sysconfig]. Fig. 12: Sector [sysconfig] Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
Page 26
Open “configuration.ini” file (or the configuration file entered above) with a text editor that supports the Linux text format. Search for section [network]. In [network], enter the new IP address of the controller, for example: eth0.mode=“static“ eth0.ip=“10.1.101.175“ Eth0.netmask=“255.255.0.0“ default_gateway=“0.0.0.0“ Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
Page 27
Wait until the LED has stopped flashing and remove the USB thumb drive. Restart the device (disconnect and re-establish the power supply). The device is configured with the values entered in the USB update and ready for use. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
Make sure all the ventilation openings are kept free of obstructions ► Do not open the device. If it is necessary to work in the device, contact the Service department. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
Use a slotted screwdriver to pull the retaining spring all the way down and remove the unit from the mounting rail at the bottom. Pull the device at the bottom away from the mounting rail. Push the device upwards and remove from the mounting rail. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
Send the metal parts for metal recycling. ► Sort the electronic parts (circuit boards, drives, etc.). ► Dispose of electronic scrap in accordance with the national laws and regulations. Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
EN 61131-2; EN 61000-6-2, industrial areas Protection class Protection rating IP20 Power supply (24 V power supply unit) Supply voltage +24 V DC (-15% / +20%) SELV max. AC voltage component 5% Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
Page 32
TCP/IP, Modbus TCP, BACnet, Profinet, EtherCat (optional) USB interfaces No. / type of interface 1x host USB 2.0 / USB plug port A No. plugging/unplugging cycles Max. 1,000 Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
Date of manufacture (year/week) CE mark Supply voltage and maximum current Disposal information rating Manufacturer (manufacturer’s address) Manufacturer’s logo QR code (identification no.) MAC addresses of device Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
Products ➔ Controllers / PLC ➔ Compact PLC ➔ CC-LITE ➔ Product A link to download the declaration of conformity can be found on the product page: Fig. 20: Download menu Berghof Automation GmbH | Arbachtalstrasse 26 | 72800 Eningen | www.berghof.com B-Fortis CC-Lite_EN_1.2...
Mozilla Public License (MPL) → FreeType License (FTL) The source code for the free software can be requested from Berghof Customer Services at cost price within three years of delivery of the device. 16.2 List of figures Fig. 1: Overview of CC-Lite ........................12 Fig.