Schematic drawing
Trigger input wiring/OPTO IN
Pin 5 is the reference level (GND) for all inputs. All three inputs can also be used with different voltages.
10.4 Flash output wiring/OPTO OUT
Recommended supply voltage
Collector-emitter saturation voltage
Collector-emitter breakdown voltage
Collector current continuous
The digital outputs are galvanically isolated using optocouplers to protect the device and the PC against
surges. Only DC voltages may be applied to the digital outputs.
The output of the optocoupler can be used as an open collector or open emitter output. This means that the
output signal can be connected to ground or to the supply voltage. The output signal is active if the collector-
emitter switch is closed.
2020-01-21
Symbol
Minimum
V
-
CC
V
0.03
CE(SAT)
V
100
(BR)CE
I
-
C
IDS NXT vegas: Hardware description
Typical
Maximum
-
30
-
0.15
-
-
-
150
Unit
V
V
V
mA
18