eta FWM-E Operating Instructions Manual

eta FWM-E Operating Instructions Manual

Fresh water module with energy-saving pumps

Advertisement

Quick Links

2016-06-22
EN
0000000131
V.009
X.36.0
22010-02
93994-001
Fresh water module
with 2 energy-saving pumps
Operating Instructions

Advertisement

Table of Contents
loading

Summary of Contents for eta FWM-E

  • Page 1 2016-06-22 0000000131 V.009 X.36.0 22010-02 93994-001 Fresh water module with 2 energy-saving pumps Operating Instructions...
  • Page 2 ETA Heiztechnik Gewerbepark 1 A-4716 Hofkirchen an der Trattnach Tel: +43 (0) 7734 / 22 88 -0 Fax: +43 (0) 7734 / 22 88 -22 info@eta.co.at www.eta.co.at...
  • Page 3: Table Of Contents

    Contents General information ..............4 Warranty, guarantee and liability .
  • Page 4: General Information

    General information General information Copyright DANGER! All contents of this document are property of ETA On non-compliance with this safety instruction, there is Heiztechnik GmbH and are protected by copyright. a risk of major physical injury. Any reproduction, transfer to third parties or use for other purposes is prohibited without written permission from the owner.
  • Page 5: Warranty, Guarantee And Liability

    For repairs of defects carried out by the customer or by a third party, ETA shall only bear the costs or remain Safety valve for the drinking water line obligated by warranty if this work was approved in...
  • Page 6: Ce-Conformity

    CE-Conformity CE-Conformity ETA Heiztechnik GmbH A-4716 Hofkirchen an der Trattnach, Gewerbepark 1 www.eta.co.at Declaration of conformity Product: Fresh water module with energy-saving pumps Types: ETA FWM-E EU Directives: 2004/108/EC Directive relating to electromagnetic compatibility (EMC Directive) 2006/95/EC Directive relating to electrical equipment designed for use within certain voltage limits...
  • Page 7: Description

    Description Technical data Description Technical data Dimensions Connections and components Technical data Tap output 33 litres/minute with 45 °C hot water at a buffer temperature of 60 °C. Pressure loss (drinking water side) 15 litres/minute = 150 mbar (1,5 mws) 33 litres/minute = 580 mbar (5,8 mws) Connections (drinking water side) DN20 (3/4") internal thread;...
  • Page 8: Function

    The temperature sensor for the hot water flow is defective. • Flashing RED (3x every 4 seconds): The temperature sensor for the hot water return is defective. • Flashing RED (4x every 4 seconds): The potentiometer for manual setting of the hot water temperature is defective. www.eta.co.at...
  • Page 9 Description Function The cold water that simultaneously flows through the the plate heat exchanger and mixes this with the hot plate heat exchanger on the secondary side absorbs heating water from the buffer. As a result of this, the this heat and exits the fresh water module as hot water. critical calcification temperature of 60°C is not reached and lime buildup is prevented.
  • Page 10: Information For Installation

    At 0.15 m³/h feed capacity, an installation with a new aluminium interconnector (16 x 2.2 mm, 20 m length, 6 fittings) has a line resistance of approx. 0.65 mWs. This roughly corresponds to the transport height of the circulation pump and thus fits. www.eta.co.at...
  • Page 11: Installation

    In this case the pipework set can be left out. For installation on the buffer, an optional pipework set is available from ETA. The room height must be at least the buffer height plus 100 mm for the installation of the pipework and the ventilation valve.
  • Page 12 Mount the 4 screws in the wall, hang the fresh water module on these and fasten in place. Mounting the fresh water module on the buffer This section describes installation on the buffer using the optional ETA piping set. Fig. 5-4: Fastening the fresh water module in place www.eta.co.at...
  • Page 13 Installation Mounting the screw joints For cold water, mount both ball valves with purging connections using the supplied flat seals. At the top, mount the ball valve on the flow connection using the supplied flat seal. Fig. 5-7: Cold water connections Fig.
  • Page 14 Fig. 5-8: Adjust the length of both flow lines buffer to the fresh water module. If there is sufficient space above the buffer, better A bleed valve is already installed in the ETA ventilation is provided when the ventilation is piping set.
  • Page 15: Circulation Set

    Installation Circulation set Circulation set Connecting the cold water pipe Connect the cold water pipe to the fresh water module. Optional circulation set for the hot water A circulation set for the hot water can optionally be installed on the fresh water module. Fig.
  • Page 16 If an external circulation set is installed instead of the safety valve to close, can be detected. If no the ETA set, don´t use thermal controlled pumps. sewer connection is available, the outlet must be Because they will stop if the return is getting warm, directed to the ground in a pipe.
  • Page 17: Configuration

    Configuration Configuration Topic of this configuration Adjusting options in function block [FWM 2pumps] Only the steps required for the configuration of this The circulation pump is already configured at the product are described below. factory (=option [Circulation pump]) as well as the hot water temperature settings via the potentiometer only The configuration of the complete heating system is (=option [Target value can be set with rotary knob]).
  • Page 18 3. Select in the lower window the terminal [S102 LZ] at the board [EM-C] and add it with [Connect]. 4. Close the window using the [Close] button. Installing a configuration Finish by pressing [Apply] to install the configuration. The configuration will then be adopted and the software restarted. www.eta.co.at...
  • Page 19: Electrical Connections

    Electrical connections Requirements Electrical connections Requirements CAN bus installation Electrical connection must only be made by Establishing a CAN bus connection qualified specialist personnel To establish the CAN-Bus connection to the boiler, The electrical installation must only be performed there a 2 terminals and the associated line in the by specialist personnel with the corresponding delivery scope.
  • Page 20: Circuit Board Em-C2

    PWM output Speed control for admixing pump S604 24 V input Flow sensor with temperature sensor S605A CAN-bus From boiler S605B CAN-bus Free CAN bus terminator resistor RS-485 terminator resistor Boot jumper Terminals marked with this symbol are not pre-wired. www.eta.co.at...
  • Page 21: Commissioning

    Carry on doing this until no more air escapes from the fresh water module. Mounting the plastic cover Reattach the plastic cover following commissioning. Pull off the protective film and affix the ETA logo in the corresponding recess.
  • Page 22: Information On Cold Water

    The salt regenerated ion exchangers or electrophysical issue of whether the lime will form solid limescale is systems – is better suited specifically for your cold governed by highly complex physical details. water. www.eta.co.at...
  • Page 23 Information on cold water Aggressive cold water Even in cold water with 20°dGH, the lime buildup is However, softening does not help in this regard as an usually so soft that it can be purged. On the other ion exchanger only replaces the calcium with sodium, hand, limescale can be formed despite a low level of meaning that the salt content that causes the corrosion water hardness in the event that a sufficient amount of...
  • Page 24: 10 Descaling

    'as new'. In the event of heavy calcification, we recommend replacing the plate heat exchanger. The fair spare part price offered by ETA means that replacement is often even cheaper than purging or descaling, both of which are labour- intensive.
  • Page 25: 11 Etatouch Controller

    ETAtouch controller Getting to know the control system 11 ETAtouch controller 11.1 Getting to know the control 3. An overview screen opens. system 11.1.1 Setting a time window Setting the charging and operation times In some function blocks, the time window for charging the tank (for example the buffer and hot water tank), or the operating times (for example for the heating circuit) are set.
  • Page 26 Sunday. Copying time windows In the following example, the time windows from Wednesday are copied to Saturday and Sunday. Fig. 11-8: Select days of the week Pressing the [Mark all days] button marks all days. www.eta.co.at...
  • Page 27 ETAtouch controller Getting to know the control system 4. Press the [Save] button to save. The overview will be updated accordingly. Close the window using the arrow on the left side. You can also access the week overview via the function block settings ( button).
  • Page 28: Fresh Water Module] Function Block

    Circulation pump (only displayed if it has been installed and is in operation) Hot water temperature (the tap is displayed only when hot water is currently being drawn) [Settings] button. In this menu, the time window can be set, for example. www.eta.co.at...
  • Page 29: Setting The Hot Water Charging Times

    ETAtouch controller [Fresh water module] function block 11.2.1 Setting the hot water charging times 11.2.2 Text menu - Adjustable parameters Open the overview screen of the set charging Adjustable parameters times and temperatures Hot water The standby times for the hot water and the set tem- Automatic venting peratures can be adjusted in the settings ( button).
  • Page 30 This parameter sets the period (pause) after a circulation pump operating phase. The control system can only restart the circulation pump after this time has elapsed. This pause is only valid inside the set time slot. The parameter can be found under: Circulation Circulation pause www.eta.co.at...
  • Page 32 DOWNLOAD www.eta.co.at...