Unit Components

NF80DS unit components are shown in Figure 1. The
gas valve, combustion air inducer and burners can be
accessed by removing the upper access panel. Electrical
components are in the control box (Figure 2) found in the
blower section.
CAUTION
Electrostatic discharge can affect electronic
components.
neutralize electrostatic charge by touching
your hand and tools to metal prior to
handling the control.
Control Box Components (Figure 2)
Unit transformer (T1) and integrated ignition control
(A92) are located in the control box. In addition, a door
interlockswitch (S51) is located in the control box.
INTEGRATED CONTROL
(A92)
DOOR INTERLOCK
SWITCH (S51)
Figure 2. Control Box
Transformer (T1)
A transformer located in the control box provides power
to the low voltage section of the unit. The transformers on
all models are rated at 40VA with a 120V primary and 24V
secondary.
Door Interlock Switch (S51)
A door interlock switch rated 14A at 120VAC is located
on the control box. The switch is wired in series with line
voltage. When the blower door is removed the unit will shut
down.
NOTE: The door interlock switch is a safety switch. Do not
by-pass or jumper switch.
31-5000736 Rev. 0
Take
precautions
to
CIRCUIT
BREAKER
(CB8)
TRANSFORMER
(T1)
Circuit Breaker (CB8)
A 24V circuit breaker is also located in the control box. The
switch provides overcurrent protection to the transformer
(T1). The breaker is rated at 3A at 32V. If the current
exceeds this limit the breaker will trip and all unit operation
will shutdown. The breaker can be manually reset by
pressing the button on the face.
Integrated Ignition Control
Shock hazard.
Disconnect
Control is not field repairable. If control is
inoperable, simply replace entire control.
Can cause injury or death. Unsafe
operation will result if repair is attempted.
The hot surface ignition control system consisting of
an integrated control (Figure 3 with control terminal
designations in Table 1 through Table 3), sensor and
ignitor (Figure 6). The integrated control and ignitor work
in combination to ensure furnace ignition and ignitor
durability. The integrated control, controls all major furnace
operations. The integrated control also features a RED
LED for troubleshooting and two accessory terminals rated
at (1) one amp. See Table 4 for troubleshooting diagnostic
codes. The nitride ignitor is made from a non-porous, high
strength proprietary ceramic material that provides long life
and trouble free maintenance.
Pin #
1
2
3
4
Table 1. 4-Pin Terminal Designations
Pin #
1
2
3
4
5
6
7
8
9
10
11
12
Table 2. 12-Pin Terminal Designations
Page 7
WARNING
power
before
Function
Combustion Air Inducer Line
Ignitor Line
Combustion Air Inducer Neutral
Ignitor Neutral
Function
High Limit Output
Not Used
24V Line
Not Used
Rollout Switch Out
24V Neutral
High Limit Input
Ground
Gas Valve Common
Pressure Switch In
Rollout Switch In
Gas Valve Out
servicing.