Lennox LI012CI-170P432-1 Service Manual page 98

Table of Contents

Advertisement

Service Manual
Step
Instruction: Some wiring terminal of this
product is with lock catch and other devices.
The pulling method is as below:
1.Remove the soft sheath for some terminals
at first, hold the circlip and then pull out the
terminals.
2.Pull out the holder for some terminals at
first (holder is not available for some wiring
terminal), hold the connector and then pull the
terminal.
8. Remove evaporator assy
Remove 3 screws fixing evaporator assy.
a
At the back of the unit, remove the
b
screw fixing connection pipe clamp and
then remove the connection pipe clamp.
First remove the left side of the evaporator
c
from the groove of bottom case and then
remove the right side from the clasp on
the bottom case.
Adjust the position of connection pipe
d
on evaporator slightly and then lift the
evaporator upwards to remove it.
Installation and Maintenance
Procedure
circlip
soft sheath
Connection pipe clamp
Groove
Evaporator assy
Screws
Evaporator assy
Screw
Bottom case
Connection pipe
holder
connector
Clasp
95

Hide quick links:

Advertisement

Table of Contents
loading