TABLE OF CONTENTS 1 - SAFETY ................................3 2 - INSTALLATION INSTRUCTIONS .......................... 5 3 - OPERATING INSTRUCTIONS ..........................9 3.1.1 Operation of the Remote Control ...................... 9 4 - MAINTENANCE ..............................10 5 - Limited Express Warranty..........................13 WARNINGS THIS ELECTRIC APPLIANCE PRODUCES INFRARED HEAT, FAILURE TO FOLLOW WARNINGS AND INSTRUCTIONS CAN CAUSE FIRE, ELECTRIC SHOCK, OR INJURY.
IMPORTANT INSTRUCTIONS When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock, and injury to persons, including the following outlined in section 1 – SAFETY. Read all instructions before installing or using this heater. This heater must be used strictly according to these instructions. 1 - SAFETY WARNINGS WARNING: FIRE OR EXPLOSTION HAZARD...
Page 4
Ensure the emitter is state and national electric codes (NEC). not cracked or chipped visually. Contact an authorized Aura dealer for support. • This product is not suitable for indoor residential use.
AURA infrared heaters produce radiant heat that warms people and objects, rather than the air around them. The heater can be wall or ceiling mounted and includes brackets which allow the user to direct the infrared heat where desired.
Page 6
4. Supply voltage and frequency must correspond to the electrical rating indicated on unit’s information plate. WALL-MOUNTED INSTALLATION THE CF40240 AND CF60240 HEATERS MUST BE INSTALLED WITH THE MOUNTING BRACKETS PROVIDED IN THE BOX. 1. Take the heater out of the box and remove all 4.
Page 7
CEILING MOUNTED INSTALLATION Heater should be hung using rigid mounting brackets, the unit must not be able to swing in any direction under applied load from wind or persons. It is highly recommended that users install the heater with the WARNING ceiling mounting hardware provided.
Page 8
ADJUSTING DIRECTIONAL POSITIONING Never attempt to move or adjust the heater angle while it is running. Personal WARNING injury could result. 1. Turn off the heaters electrical supply line from the main power supply. 2. Allow the heater to cool before adjusting the angle. 3.
1. Use 2 pieces AAA, 1.5V batteries (not included) in the remote control. Remove the batteries when not in use for an extended period of time to increase battery life. 2. Contact your local authorized Aura Dealer for remote replacement.
3. The remote-control function may not work if there is a barrier between the remote control and heater. Replace the batteries as required to ensure correct remote functionality. 4 - MAINTENANCE WARNINGS 1. Allow the heater and the emitter to cool down before handling. Installation and maintenance must be performed by a qualified technician.
Page 11
1. WARNING! TURN OFF THE POWER AND Caution! Disconnect metal locking DISCONNECT THE HEATER FROM THE MAIN connectors by squeezing the metal tab. POWER SUPPLY. FAILURE TO DISCONNECT HEATER BEFORE REPLACING THE EMITTER COULD CAUSE ELECTRIC SHOCK OR DEATH! 2. Turn OFF the power and disconnect from main power supply.
Page 12
Carefully replace the protective aluminum grille and screw the protective end cap in place. Due to ongoing product improvements, specifications and dimensions are subject to change and correction without notice and without incurring obligations. Determining the application and suitability for use of any product is the responsibility of the installer.
5 - LIMITED EXPRESS WARRANTY Limited Express Warranty AURA® Infrared Heaters RESIDENTIAL INSTALLATION/USE: purchase. The consumer must retain a receipted bill of sale as proof of LIMITED ONE (1) YEAR PARTS WARRANTY warranty period. Without this proof, the express warranty begins on the Inforesight Consumer Products Inc.