9.3 S&H (Sample & Hold)
The S&H modul consists of the control elements [gate] (21) and [source] (22) on the frontpanel and
"TRIG-S&H" (4) on the rearpanel. A Sample & Hold uses an input (source), an output and a trigger input
(gate). The input can be fed by any altering voltage signal (audio or modulation). As soon as the gate is
triggered by a pulse, the current voltage level at the input is sampled, transferred to the output and
held. Continous signals can be "sliced" with this module. Fig. 9.3.1 shows the structure of the S&H unit.
TRIG-S&H(4r)
gate (21)
LFO
Trigger
S&H
(Sample
& Hold)
DYN
LFO
source (22)
RAND
Fig. 9.3.1 Sample & Hold (S&H)
front: (21) [gate]
The [gate]-switch (21) selects one out of three signals for the gate.
Position "TRIG" (left):
Position "LFO" (center):
Position "EXT" (right):
front: (22) [source]
The [source]-switch (22) selects one out of three sources for the gate.
Position "DYN" (left):
Position "LFO" (center):
Position "RAND" (right):
Please note: After powering on the unit, the randomgenerator needs approx. 8 sec. to become opera-
tional.