Installation Procedure
When using ELB for AC036/048/060TX****
Power supply
MCCB
ELB
The appearance of the unit may be different
from the picture depending on the model.
CAUTION
10
English
Electrical
component box
Indoor Unit
AC036/048/060TX**C* (1-phase)
1(L)
2(N)
L
N
Outdoor-to-
Main power
indoor power
cable
cable
AC048/060TX**H* (3-phase)
1(L)
2(N)
L1(R)
L2(S)
L3(T)
Outdoor-to-
3-phase 4-wire
indoor power
main power cable
cable
(AC 380V)
F1
F2
Cable tie
Communication cable
F1
F2
N
Cable tie
Communication
cable