Download Print this page

Newco 20 to 1 Service Manual page 2

20:1 brewer

Advertisement

WARNING:
- Read and follow installation / setup instructions before plugging or wiring in machine to electrical
circuit. Warranty will be void if machine is connected to any voltage other than that specified on the name plate.
Plumber's Installation Instructions
1) Plumb brewer in to water supply using 1/4 inch copper or plastic tubing. Flush water line before installing brewer
to remove sediment. Brewer should be connected to COLD WATER LINE for best operation.
2) Water pressure should be at least 20 lbs. For less than a 25 ft run, use 1/4" tubing and connect to 1/2" or larger
water line. The inlet water fitting on the back of the brewer is a 1/4" flare fitting.
3) If installed with saddle valve, the valve should have a minimum of 1/8" port hole for up to 25 ft run, and 5/16" port
hole for over 25 ft runs.
4) Check for leaks.
Initial Setup Instructions
Ensure power switch on right rear of unit is in the off position. Plug or wire brewer to the appropriate voltage circuit as
indicated on the serial tag. Turn power switch to the on position. Brewer tank will begin to fill. Once the tank is full
the brewer will begin to heat. Ready light will come on to indicate tank has finished heating.
CAUTION: The water faucet will dispense hot water anytime the handle is pulled.
Programming
The brewer has two program modes, service mode and user mode. The service mode is used to establish basic
operating parameters of the unit while the user mode allows the three buttons to be programmed for brewing into
various containers or for varying beverage volumes. Programming mode is initiated as outline below. The following
will outline the various steps as displayed by the programming "screens". The screens will loop continuously until
exiting the mode.
Service Mode is entered by holding any two of the buttons on the face of the machine while powering up the brewer.
The brewer firmware revision number is displayed for a couple of seconds when entering this mode. The table below
list the items that may be programmed along with available values or settings. Use the center brew button to advance
through the items and the left and right button to decrement or increment the values/selection respectively. These
items are programmed at the factory and will typically not need adjustment.
Item Selected
Water Temperature
Probe
End of Cycle Beeper
Brew Pump Speed
Not Used
Pump Calibration
Volume Delivered
During Calibration Step
Service Data
Exit
Pump calibration is necessary when the pump speed is changed or if the brewer is delivering substantially more or
less beverage than what it has been programmed for in the user mode. Pump speed may be adjusted up or down if
required to deliver water at a faster or slower rate to meet a specific beverage taste profile. Calibration tells the
brewer control how much hot water is delivered within a specific time frame so it can adjust the time required to run to
deliver the desired brew volumes.
NB INSTALLATION / SETUP INSTRUCTIONS
Screen
Values
Comment
Example
Available
200
170-205
Degrees F
Std
Std, ro
Std should be used in all cases except for when connected to a
reverse osmosis system.
On
On, OFF
Used to audibly indicate brew cycle has completed with a series of
beeps.
b:05
1-10
Pump speed used for brewing
F:05
1-10
No effect. Unused feature.
CAL
N/A
See instructions below. Must be done if pump speed modified.
39.0
16.0-99.9
Ounces. Only displays if calibration cycle was run.
Srv
N/A
Used to view temperature & probe data. See Service Data below.
End
N/A
Use left or right button when displayed to exit this mode.
PreRelease Manual PN 119985 Rev 09-26-05 Firmware Rev 3
2
Continued on next page

Advertisement

loading

This manual is also suitable for:

20:120:1-td