WARNINGS
Installation:
 This device must be installed only by qualified technician
 Installer must follow current regulations
 The manufacturer shall not be liable for any improper use of the product, incorrect installation or failure to comply with instructions of
this manual and the law regarding electrical systems
 Any intervention carried out by not qualified technician can damage the device
Installation environment:
 Do not install the control panel in very humid or warm environment, near to baths, sinks, etc. Do not install the device outdoor
 For a solid and reliable installation, make sure the installation wall surface is flat
 Fix the receiver to a height that allows easy access the front panel
 The receiver is protected against tampering. Anyway, it is recommended to install the device within a detection zone of the alarm system
 Do not install the receiver in a shielded environment or near other receivers/transmitters with the same working frequency. Before fix
the device and peripherals run some tests to verify the system and ensure a proper behaviour and coverage of wireless sensors
 Pay attention to radio emitters near the installation. In this case run tests of correct working for more days
[AN] [SPV] [Serie 100]
INSTALLATION AND USE MANUAL
MADE IN ITALY

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RX808-LCD and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Duevi RX808-LCD

  • Page 1 RX808-LCD 80 CHANNELS WIRELESS RECEIVER WITH LCD DISPLAY 19.09-M:1.4-H:x.x-F:SWCABD -ENG [AN] [SPV] [Serie 100] MADE IN ITALY INSTALLATION AND USE MANUAL WARNINGS Installation:  This device must be installed only by qualified technician  Installer must follow current regulations  The manufacturer shall not be liable for any improper use of the product, incorrect installation or failure to comply with instructions of this manual and the law regarding electrical systems ...
  • Page 2: Table Of Contents

    INDEX RX808-LCD ..............................3 TECHNICAL ..............................4 FRONT PANEL ..............................6 PROGRAMMING MENU ............................ 7 LANGUAGE ............................... 7 ZONES LEARNING .............................. 7 ACTIVATORS LEARNING ............................7 RADIO TEST ..............................7 BEEP ARMING ..............................7 DOOR CONTROL ..............................8 CTSR AND MINI-C .............................. 8 RECEIVER MODE (IMPULSIVE RELAY) ........................
  • Page 3: Rx808-Lcd

    This is a radio receiver with 80 radio zones combined to 8 relay outputs (groups of 10 radio zones for each output). Each radio zone hosts one detector. When RX808-LCD receives the alarm radio code from a zone, it activates the combined relay output (N.C. type). Each radio sensor is completely recognized by receiver (included opened/closed door in compatible sensors).
  • Page 4: Technical

    TECHNICAL RADIO ZONES 80 radio zones – Each zone can store one detector REMOTE CONTROLS 9 remote controls for arming/disarming the receiver and drive the arming output (COM-NC-NA) 8 relay outputs for alarm from radio zones (not from remote controls) Each output is combined to one group of 10 radio zones (eight groups) Relay data: 24 V / 500 mA...
  • Page 5 JUMPERS CLOSED Programming mode SETUP PROGRAMMING OPENED Normal working CLOSED Tamper disabled TAMPER OPENED Tamper enabled TERMINALS Antenna Input for TOTAL arming (no PARTIAL) and Connect this input to Arming Status output (+INS) of the control panel disarming the receiver (0 V = system disarmed, +12 V = system armed) Power...
  • Page 6: Front Panel

    Dry contact relay output 10. Programmable: Bi-stable / Impulsive (remote control driven) (Normalmente Closed) Connect the receiver to arming wired input of the control panel to arm/disarm it via RX808- (Normally Opened) FRONT PANEL Display Data visualization MENU EDIT OK / Next / Cancel Select / change option RX808-LCD front panel...
  • Page 7: Programming Menu

    PROGRAMMING MENU To enter in programming menu: 1. Open the receiver 2. With receiver powered, close the jumper SETUP 3. The receiver emits two “beep” and enter immediately in programming menu 4. Use the MENU button to scroll the menu items, the EDIT button to change settings 5.
  • Page 8: Door Control

    DOOR CONTROL This function advice about opened zones at arming. The receiver emits a special acoustic alert. At this point it is possible to: 1. Confirm: press the arm button on remote control or leave the positive signal on RST input or leave the alert time ends: the opened zones will be bypassed 2.
  • Page 9: Anti-Blinding

    ANTI-BLINDING Alert function in case of disturbing radio transmission (radio blinding attempts). In case of blinding, the receiver alerts with a “Blinding” message on display and activating the output LWB. ENTRY TIME Delay time before consider alarm after – at receiver armed – a violation of the zones 1 ÷ 10. If –...
  • Page 10: Reset

    RESET BEFORE PROCEED WITH THE DEVICE PROGRAMMING, IT IS RECOMMENDED TO PERFORM THE FOLLOWING STEPS IN ORDER TO ERASE THE MEMORY AND ERASE ANY FACTORY TEST SETTING. These procedure allows to delete all the radio zones and remote controls stored in receiver. ...
  • Page 11: Zone Management (Sensors)

    ZONE MANAGEMENT (SENSORS) The receiver can store sensors in its zones by two different ways:  “AN” mode (factory mode): for devices models “with AN”  “by detection” mode: for devices without “AN” function (old devices) To switch from one learning mode to other: ...
  • Page 12: By Detection" Learning Mode

    “BY DETECTION” LEARNING MODE THIS MODE IS FOR “BY DETECTION” LEARNING ONLY (OLD DEVICES) 1. Enter in programming menu (jumper SETUP closed) and select “Zone Learning” 2. Select the memory position to use with EDIT button (by holding the button, the memory position increase quickly): EDIT Zone Learning Zone Learning...
  • Page 13: Activator Management

    ACTIVATOR MANAGEMENT LEARN AN ACTIVATOR 1. Enter in programming menu (jumper SETUP closed) and select “Learn. Activator” 2. Select the memory position using the EDIT button (hold down the button to increase quickly the memory position): EDIT Learn. Activator Learn. Activator Remote Remote 3.
  • Page 14: Arming And Disarming

    ARMING AND DISARMING It is possible to arm (activate) the receiver and the connected control panel, in two ways: 1. With remote controls: the receiver must be programmed in MASTER mode, the control panel must be connected to the output COM- NC-NA.
  • Page 15: Alarm Memory (Events Log)

    The detectors automatically transmit a “live” radio code each hour. When the supervision is active, the receiver verifies to receive at least one “live” radio code from each detector within the selected time window (4, 8 or 12 hours). If the RX808-LCD does not receives a “live” code within this time, it will be signalled as “missed supervision”.