Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
Contents Introduction ..........................Validity of documentation......................Using the documentation ......................Definition of symbols......................... Safety ............................Intended use ..........................Safety regulations ........................Safety assessment ........................Use of qualified personnel ......................Warranty and liability ........................ Disposal ............................ For your safety .......................... Unit features ...........................
Introduction Validity of documentation This documentation is valid for the product PZW. It is valid until new documentation is pub- lished. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product. Using the documentation This document is intended for instruction.
INFORMATION This gives advice on applications and provides information on special fea- tures. Safety Intended use The unit operates as a pulse relay in accordance with EN ISO 12100:2010 section 6.2.11.10, 6.3.2.4 and 3.28.9 (inching cir- cuit for limited movement of hazardous machine components during installation, set up and positioning) In safety circuits in accordance with EN 60204-1 The unit is designed for use with...
Safety regulations Safety assessment Before using a device, a safety assessment in accordance with the Machinery Directive is required. The product as an individual component fulfils the functional safety requirements in accord- ance with EN ISO 13849 and EN 62061. However, this does not guarantee the functional safety of the overall plant/machine.
For your safety The unit meets all the necessary conditions for safe operation. However, please note the following: Note for overvoltage category III: If voltages higher than low voltage (>50 VAC or >120 VDC) are present on the unit, connected control elements and sensors must have a rated insulation voltage of at least 250 V.
Block diagram/terminal configuration Types: AC : 110 - 120 VAC; Order no. 774044 : 230 V AC; Order no. 774017 *Insulation between the non-marked area and the relay contacts: Basic insulation (over- voltage category III), Protective separation (overvoltage category II) Types: DC : 24 VDC;...
Function description The unit is ready for operation when the feedback loop Y1-Y2 is closed. Input circuit closed (supply voltage is present) "POWER" LED is illuminated. The safety contact 17-18 will be closed immediately and the auxiliary contacts 25-26, 35-36 will open, time sequence starts. The "OUT" LED is lit. The safety contact 17-18 is opened redundantly and the auxiliary contacts 25-26, 35-36 will close once the set pulse time has elapsed.
Installation The unit should be installed in a control cabinet with a protection type of at least IP54. Use the notch on the rear of the unit to attach it to a DIN rail (35 mm). When installed vertically: Secure the unit by using a fixing element (e.g. retaining bracket or end angle).
Preparing for Operation Connection Supply voltage Input circuit is driven by connect- ing U Feedback loop Without feedback loop monitor- With feedback loop monitoring Link or contacts from external con- tactors Application example S31 S32 S11 S12 S13 S14 17 25 35 Y1 Y2 PNOZ X3 26 36 S21 S22 S33 S34...
Operation When the relay outputs are switched on, the mechanical contact on the relay cannot be tested automatically. Depending on the operational environment, measures to detect the non-opening of switching elements may be required under some circumstances. When the product is used in accordance with the European Machinery Directive, a check must be carried out to ensure that the safety contacts on the relay outputs open correctly.
Dimensions in mm 75 (2.95") 45 (1,77") 87 (3.42") Technical details Order no. 774017 – 774019 See below for more order numbers General 774017 774019 CE, EAC (Eurasian), TÜV, cULus CE, EAC (Eurasian), TÜV, cULus Certifications Listed Listed Electrical data 774017 774019 Supply voltage...
Page 14
Relay outputs 774017 774019 Number of output contacts Safety contacts (N/O), delayed Auxiliary contacts (N/C), delayed Max. short circuit current IK 1 kA 1 kA Utilisation category In accordance with the standard EN 60947-4-1 EN 60947-4-1 Utilisation category of safety con- tacts AC1 at 240 V...
Page 15
Relay outputs 774017 774019 Utilisation category in accordance with UL Voltage 240 V AC G. P. 240 V AC G. P. With current Voltage 24 V DC Resistive 24 V DC Resistive With current Pilot Duty B300, R300 B300, R300 External contact fuse protection, safety contacts In accordance with the standard EN 60947-5-1...
Page 16
Environmental data 774017 774019 Vibration In accordance with the standard EN 60068-2-6 EN 60068-2-6 Frequency 10 - 55 Hz 10 - 55 Hz Amplitude 0,35 mm 0,35 mm Airgap creepage In accordance with the standard EN 60947-1 EN 60947-1 Overvoltage category III / II III / II Pollution degree...
Page 17
Order no. 774042 – 774044 General 774042 774044 CE, EAC (Eurasian), TÜV, cULus CE, EAC (Eurasian), TÜV, cULus Certifications Listed Listed Electrical data 774042 774044 Supply voltage Voltage 24 V 110 - 120 V Kind Voltage tolerance -15 %/+10 % -15 %/+10 % Output of external power supply (AC)
Page 18
Relay outputs 774042 774044 Utilisation category of auxiliary con- tacts AC1 at 240 V 240 V Min. current 0,01 A 0,01 A Max. current Max. power 1500 VA 1500 VA DC1 at 24 V 24 V Min. current 0,01 A 0,01 A Max.
Page 19
Relay outputs 774042 774044 External contact fuse protection, auxiliary contacts Max. melting integral 240 A²s 240 A²s Blow-out fuse, quick Blow-out fuse, slow Blow-out fuse, gG Circuit breaker 24 V AC/DC, characteristic B/C Conventional thermal current Contact material AgSnO2 + 0,2 µm Au AgSnO2 + 0,2 µm Au Times 774042...
Page 20
Mechanical data 774042 774044 Mounting position Mechanical life 10,000,000 cycles 10,000,000 cycles Material Bottom PPO UL 94 V0 PPO UL 94 V0 Front ABS UL 94 V0 ABS UL 94 V0 PPO UL 94 V0 PPO UL 94 V0 Connection type Screw terminal Screw terminal Mounting type...
Safety characteristic data NOTICE You must comply with the safety characteristic data in order to achieve the required safety level for your plant/machine. Operating EN ISO EN ISO EN 62061 EN 62061 IEC 61511 IEC 61511 EN ISO mode 13849-1: 13849-1: 13849-1: SIL CL [1/h] 2015...
Supplementary data Service life graph The service life graphs indicate the number of cycles from which failures due to wear must be expected. The wear is mainly caused by the electrical load; the mechanical load is negli- gible. Switching current (A) Example Inductive load: 0.2 A Utilisation category: AC15...
This product/these products meet the requirements of the directive 2006/42/EC for ma- chinery of the European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/support/downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost- fildern, Germany Operating Manual PZW...
Page 24
We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com, Internet: www.pilz.com...