Advertisement

Quick Links

​ M ODEL UVM9
Air Purifier
Installation, Operation and Maintenance Manual
Doc Reference No: UVM9
Page ​ 1 ​ of ​ 1 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the UVM9 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PureAir UVM9

  • Page 1 ​ M ODEL UVM9 Air Purifier Installation, Operation and Maintenance Manual Doc Reference No: UVM9 Page ​ 1 ​ of ​ 1 4...
  • Page 2: Table Of Contents

    Routine maintenance Air filter replacement Catalyst replacement UV lamp replacement TROUBLESHOOTING TECHNICAL SPECIFICATION AMENDMENT RECORD SHEET REVISION DATE PREPARED BY ITEM AFFECTED INSERTED BY & DATE 29/04/2020 First Issue Doc Reference No: UVM9 Page ​ 2 ​ of ​ 1 4...
  • Page 3 Air Disinfection System Operation and Maintenance Manual OVERVIEW These instructions describe the installation, operation and maintenance of the MicroTek UVM9 air purifier. If you do not understand these instructions, please call MicroTek Processes for clarification before commencing any work. MicroTek Processes, reserves the rights to make engineering refinements that may not be described herein.
  • Page 4: Introduction

    Operation and Maintenance Manual INTRODUCTION Purpose of the Manual This manual is intended to support the operation and maintenance of the PureAir™ UVM9 air purifier supplied by MicroTek Processes. The enclosed manual covers the UVM9 purifier only. The package comprises the following major components: ●...
  • Page 5: Operation

    OPERATION Principles of Operation The UVM9 air purifier is a self contained air purifier that requires period maintenance as set out within this manual. Operation is either manually via the Mode Switch on the top of the purifier which selects either constant on or Intelligent operation via a programmed function that starts the purifier when the room is occupied and the fans rin for a set time.
  • Page 6: Safety Instructions

    Health, Safety and Welfare of their employees. General Health and Safety This PureAir​ UVM9 purifier has few exceptional Health and Safety Risks associated with it. TM​ Listed below are some of those that should be considered in the installation, operation and maintenance of the equipment.
  • Page 7: Installation

    INSTALLATION General Description of system The UVM9 air purifier comprises a wall mounted purifier complete with a 24V power supply that needs to be connected to a 110v/220v 1 phase 50/50Hz supply. The basic parts of the purifier are a replaceable filter, 4 small fans that draw the air through the purifier, a UV lamp and catalytic filter.
  • Page 8: Electrical Installation Requirements

    Electrical installation requirements Wiring The UVM9 is supplied with a separate power supply to provide 24 Volts to the purifier via a 3 metre flying lead fitted with a plug suitable for country/region of installation. Note the requirements for the incoming electrical supply is ​ 1 10/220V, 50/60Hz, 1 Phase​ and must be fitted with a disconnect/fuse rated at ​...
  • Page 9: Maintenance

    MAINTENANCE Routine Maintenance The UVM9 air purifier is designed for the minimum of maintenance. However, regular inspection and preventative maintenance of the plant and equipment, together with a systematic method of recording plant operation, are essential for the long-term reliability of the equipment.
  • Page 10: Catalyst Replacement

    The outer case can then be gently eased off its back plate, note the wires for the sensor and indicator light are attached to the front cover. With the outer cover removed you can now gain access to the inside of the unit. Fig 3. Doc Reference No: UVM9 Page ​ 1 0​ of ​ 1 4...
  • Page 11: Uv Lamp Replacement

    5.4 UV Lamp Lamp Replacement The following explains the sequence to change the lamp fitted to the UVM9. The UV lamp fitted to the purifier should be replaced every 12 months with a replacement bought from MicroTek or its approved stockist.
  • Page 12 16. Switch the unit on a check for operation note a faint blue light should be seen through the front filter. Fig 5. Keep a record of ultraviolet lamp replacement dates and servicing dates. Fig 1. Fig.2 Fig 3. Fig 4. Fig 5. Doc Reference No: UVM9 Page ​ 1 2​ of ​ 1 4...
  • Page 13: Troubleshooting

    ● There is electrical power to the power supply feeding the UVM9. ● The UVM9 is switched on. The power on indicator on the front of the unit will be lit. If there is power to the unit and the lamp indicator is lit but the unit is not operating as indicated by the internal fan operating, then the fault is internal and under no circumstances should you attempt a repair.
  • Page 14: Technical Specification

    220Vac to 240Vac Frequency 50/60Hz Rated power 30W (Standby 3W) Fuse rating Connection Flying lead Dimensions 12"w X 10"h X 4"d (300mm x 250mm x 100mm) Weight 3.3lbs (1.5Kg) Doc Reference No: UVM9 Page ​ 1 4​ of ​ 1 4...

Table of Contents