Fujitsu AOU36RLAVM4 Installation Manual page 14

Vrf system outdoor unit
Table of Contents

Advertisement

-4.0°F (-20°C)
-0.4°F (-18°C)
3.2°F (-16°C)
Outdoor tempera-
6.8°F (-14°C)
ture zone bound-
10.4°F (-12°C)
ary temperature
36
14.0°F (-10°C)
A (*1)
17.6°F (-8°C)
21.2°F (-6°C)
24.8°F (-4°C)
For more details on settings for this item, see the Design & Technical manual.
42.8°F (6°C)
14.0°F (-10°C)
17.6°F (-8°C)
21.2°F (-6°C)
24.8°F (-4°C)
28.4°F (-2°C)
32.0°F (0°C)
Outdoor tempera-
35.6°F (2°C)
ture zone bound-
ary temperature
37
39.2°F (4°C)
B (*1)
42.8°F (6°C)
46.4°F (8°C)
50.0°F (10°C)
53.6°F (12°C)
57.2°F (14°C)
60.8°F (16°C)
64.4°F (18°C)
For more details on settings for this item, see the Design & Technical manual.
Capacity prior-
Off (quiet priority)
ity setting (in low
On (capacity priority)
noise mode) (*1)
40
If the cooling/heating performance becomes insufficient when the low noise mode is set, it is
possible to set "capacity priority" that automatically cancels the low noise mode (once perfor-
mance is restored, the mode will automatically return to the low noise mode).
Off (Normal)
Low noise mode
41
setting (*1)
On (Low noise mode)
42
Prohibited (Factory default)
Normal mode
Maximum circuit
20 A
breaker setting
55
30 A
For more details on settings for this item, see the Design & Technical manual.
60
Prohibited (Factory default)
61
Prohibited (Factory default)
62
Prohibited (Factory default)
Setting number (x00)
Setting number (x01)
Electricity meter
No. setting 1 (*2)
70
Setting number (x98)
Setting number (x99)
Set the ones digit and tens digit of the No. of the electricity meter connected to CN135.
Setting number (0xx)
Electricity meter
Setting number (1xx)
No. setting 2 (*2)
71
Setting number (2xx)
Set the hundreds digit of the No. of the electricity meter connected to CN135.
Setting number (xx00)
Setting number (xx01)
Electricity meter
pulse setting
1 (*3)
72
Setting number (xx98)
Setting number (xx99)
Set the ones digit and tens digit of the No. of the electricity meter pulse setting
connected to CN135.
Setting number (00xx)
Setting number (01xx)
Electricity meter
pulse setting
2 (*3)
73
Setting number (98xx)
Setting number (99xx)
Set the hundreds digit and thousands digit of the electricity meter pulse setting con-
nected to CN135.
90
Prohibited (Factory default)
92
Prohibited (Factory default)
96
Prohibited (Factory default)
*1: Do not set this for outdoor units with Slave setting.
*2: When electricity meter No. is set to "000" and "201 to 299", the pulses input to CN135
become ineffective. Available setting number is "001" to "200"
*3: When the electricity meter pulse setting is set to "0000", the pulses input to CN135
become ineffective. Available setting number is "0001" to "9999"
En-13
0
0
0
1
0
2
0
3
3
6
0
4
0
5
0
6
0
7
0
8
0
0
0
1
0
2
0
3
0
4
0
5
0
6
0
7
3
7
0
8
0
9
1
0
1
1
1
2
1
3
1
4
1
5
0
0
4
0
0
1
0
0
4
1
0
1
4
2
0
0
0
0
5
5
0
1
0
2
6
0
0
0
6
1
0
0
6
2
0
0
0
0
0
1
7
0
9
8
9
9
0
0
7
1
0
1
0
2
0
0
0
1
7
2
9
8
9
9
0
0
0
1
7
3
9
8
9
9
9
0
0
0
9
2
0
0
9
6
0
0
(1) Turn on the power of the outdoor unit and enter standby mode.
• When system is normal
POWER/MODE lamp lights up.
(ERROR lamp is off.)
POWER/MODE
ERROR
POWER
ERROR
MODE
lamp: ON
lamp: OFF
LED101
LED102
(GREEN)
(RED)
7-segment
LED105
LED104
display:
turn off
MODE
SELECT
ENTER
/EXIT
ENTER
MODE/EXIT
button
SW107
SW108
SW109
button
SELECT button
(2) Setting method
Use the "MODE/EXIT", "SELECT",
and "ENTER" buttons to configure
settings according to the proce-
dures below.
(If no setting is made, the factory
default setting will be displayed.)
1: Function setting
First 2 digits Last 2 digits
7-segment LED display (LED 105, LED 104)
(When [F3] to [F9] are displayed, continue to press
the "SELECT" button until [F2] is displayed.)
(Blinking)
2: Setting the first
2 digits
Every press of the
"SELECT" button will
change the setting
number for the first 2
digits.
Setting is complete when the lamp lights up
Press "ENTER" button to return to "2: Setting the
first 2 digits" (If there is no operation for 5 seconds
after the setting, the display will return to "2: Setting
the first 2 digits".)
Setting is complete when the lamp lights up
Press "ENTER" button to return to "2: Setting the
first 2 digits" (If there is no operation for 5 seconds
after the setting, the display will return to "2: Setting
the first 2 digits".)
EXIT: Press the "MODE/EXIT" button to cancel the setting mode.
• When system is abnormal
Check the settings as there is an error in the
settings for outdoor unit address
(DIP switch SET 3-1, 2) or number of con-
nected slave units (DIP switch SET 3-3, 4).
POWER/MODE
POWER
ERROR
MODE
ERROR lamp:
lamp: ON
Blinking
LED101
LED102
(GREEN)
(RED)
LED105
LED104
7-segment
display:
MODE
SELECT
ENTER
"-" display
/EXIT
SW107
SW108
SW109
: Press the "MODE/EXIT" button
: Press the "SELECT" button
: Press the "ENTER" button.
: Press the "ENTER" button for
more than 3 seconds.
3: Setting the last 2 digits
Continue to press the "SELECT" button until the
desired number appears at the last 2 digits.
(Continue to press the "SE-
LECT" button until the desired
number appears at the last 2
digits.)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aou48rlavm4Aou60rlavm4

Table of Contents