M-system R7L-EC8B Instruction Manual

Pnp transistor output extension module, 8 points

Advertisement

Quick Links

INSTRUCTION MANUAL
PNP TRANSISTOR OUTPUT EXTENSION MODULE, 8 points
BEFORE USE ....
Thank you for choosing M-System. Before use, please check
contents of the package you received as outlined below.
If you have any problems or questions with the product,
please contact M-System's Sales Office or representatives.
■ PACKAGE INCLUDES:
Transistor output extension module ..................................(1)
■ MODEL NO.
Confirm Model No. marking on the product to be exactly
what you ordered.
■ INSTRUCTION MANUAL
This manual describes necessary points of caution when
you use this product, including installation, connection and
basic maintenance procedures.
POINTS OF CAUTION
■ POWER INPUT RATING & OPERATIONAL RANGE
• Locate the power input rating marked on the product and
confirm its operational range as indicated below:
24V AC rating: 24V ±10%, 50/60 Hz, approx. 15mA
24V DC rating: 24V ±10%, approx. 10mA
■ GENERAL PRECAUTIONS
• Before you remove the unit or mount it, turn off the power
supply and output signal for safety.
■ ENVIRONMENT
• Indoor use.
• When heavy dust or metal particles are present in the
air, install the unit inside proper housing with sufficient
ventilation.
• Do not install the unit where it is subjected to continuous
vibration. Do not subject the unit to physical impact.
• Environmental temperature must be within -10 to +55°C
(14 to 131°F) with relative humidity within 30 to 90% RH
in order to ensure adequate life span and operation.
■ WIRING
• Do not install cables close to noise sources (relay drive
cable, high frequency line, etc.).
• Do not bind these cables together with those in which
noises are present. Do not install them in the same duct.
■ FUNCTIONAL BLOCK SETTING
• Functional blocks regarding the extension module are set
by the basic module. Refer to the instruction manual for
the basic module for detailed information.
■ AND ....
• The unit is designed to function as soon as power is sup-
plied, however, a warm up for 10 minutes is required for
satisfying complete performance described in the data
sheet.
SEN TRONIC
(L
W
)
ON
ORKS
056 222 38 18
mailbox@sentronic.com
AG
MODEL
COMPONENT IDENTIFICATION
Discrete Output Status Indicator LED
6
1
■ DISCRETE OUTPUT STATUS INDICATOR LED
Used to show discrete output signal status.
ON
: LED ON
OFF
: LED OFF
■ OUTPUT TERMINAL ASSIGNMENT
6
7
+24V
Y1
1
2
3
0V
Y0
Y2
NO.
ID
FUNCTION
1
0V
0V
2
Y0
Output 0
3
Y2
Output 2
4
Y4
Output 4
5
Y6
Output 6
CONNECTING THE EXTENSION MODULE
1) Remove the extension connector cover located at the side
of the basic module.
2) Connect the extension module.
3) Mount the combined module on a DIN rail.
www.sentronic.com
R7L-EC8B
0 1 2 3 4 5 6 7
7
8
9
10
2
3
4
5
Output Terminals
8
9
10
Y3
Y5
Y7
4
5
Y4
Y6
NO.
ID
FUNCTION
6
+24V
24V DC (common)
7
Y1
Output 1
8
Y3
Output 3
9
Y5
Output 5
10
Y7
Output 7
EM-7804-P Rev.1 P. 1 / 2

Advertisement

loading

Summary of Contents for M-system R7L-EC8B

  • Page 1 MODEL ORKS BEFORE USE ..COMPONENT IDENTIFICATION Thank you for choosing M-System. Before use, please check Discrete Output Status Indicator LED contents of the package you received as outlined below. If you have any problems or questions with the product, please contact M-System’s Sales Office or representatives.