Unit Installation; Preparing The Installation Site; Installation Site Requirements Of The Outdoor Unit; Additional Installation Site Requirements Of The Outdoor Unit In Cold Climates - Daikin 2MXM40A2V1B9 Installation Manual

R32 split series
Table of Contents

Advertisement

4

Unit installation

WARNING
Installation shall be done by an installer, the choice of
materials and installation shall comply with the applicable
legislation. In Europe, EN378 is the applicable standard.
4.1

Preparing the installation site

WARNING
The appliance shall be stored so as to prevent mechanical
damage and in a well-ventilated room without continuously
operating ignition sources (e.g. open flames, an operating
gas appliance, or an operating electric heater). The room
size shall be as specified in the General safety precaution.
4.1.1
Installation site requirements of the
outdoor unit
Mind the following spacing guidelines:
▪ Wall facing 1 side:
>100
b
a
▪ Wall facing 2 sides:
b
>100
a
>50
▪ Wall facing 3 sides:
b
>150
a
>50
>300
(mm)
a
Air outlet
b
Air inlet
Allow 300 mm of work space below the ceiling surface and 250 mm
for piping and electrical servicing.
2MXM40+50A9
R32 Split series
3P600450-8T – 2022.09
Do NOT install the unit in sound sensitive areas (e.g. near a
bedroom), so that the operation noise will cause no trouble.
Note: If the sound is measured under actual installation conditions,
the measured value might be higher than the sound pressure level
>50
mentioned in "Sound spectrum" in the data book due to
environmental noise and sound reflections.
b
a
The outdoor unit is designed for outdoor installation only, and for
(mm)
ambient temperatures within the following ranges (unless otherwise
specified in the operation manual of the connected indoor unit):
a
>150
4.1.2
b
>50
(mm)
Protect the outdoor unit against direct snowfall and take care that the
outdoor unit is NEVER snowed up.
b
a
Baffle plate
b
Prevailing wind direction
c
Air outlet
INFORMATION
The sound pressure level is less than 70 dBA.
Cooling mode
–10~46°C DB
Additional installation site requirements
of the outdoor unit in cold climates
c
a
Snow cover or shed
b
Pedestal
c
Prevailing wind direction
d
Air outlet
4 Unit installation
b
a
Heating mode
–15~24°C DB
a
c
b
Installation manual
11