ESSENCE OF EVOLUTION COMBI OVENS
STACKED INSTALLATION
(READ ALL INSTRUCTIONS BEFORE USE)
TO BE USED IN CONJUNCTION WITH USER MANUAL SUPPLIED WITH OVEN
Electric Models:
MTE5WRT / MTE5WLT
MTE7XWRT / MTE7XWLT
MTE10XWRT / MTE10XWLT
Revision: 01 - 19/12/2022 - A

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Giorik MovAir MTE5WRT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for STODDART Giorik MovAir MTE5WRT

  • Page 1 ESSENCE OF EVOLUTION COMBI OVENS STACKED INSTALLATION (READ ALL INSTRUCTIONS BEFORE USE) TO BE USED IN CONJUNCTION WITH USER MANUAL SUPPLIED WITH OVEN Electric Models: MTE5WRT / MTE5WLT MTE7XWRT / MTE7XWLT MTE10XWRT / MTE10XWLT Revision: 01 - 19/12/2022 - A...
  • Page 2: Table Of Contents

    Water Connection ..... . 9 Stoddart Standard Filter Stoddart Supplied Reverse Osmosis Filter Drainage Connection ....13 Due to continuous product research and development, the information contained herein is subject to change without notice.
  • Page 3: Installation

    Clean off any remaining residue from the interior/exterior of the unit using a clean cloth dampened with warm soapy water Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 2...
  • Page 4: Positioning

    OVEN SOURCE SOURCE For distances under 500mm, it is mandatory for Stoddart heat shields to be fitted (for a minimum distance of 50mm from the surface of the oven). Failure to adhere to minimum clearances may void the oven warranty.
  • Page 5: Stacking Kit

    Lower Humidity Vent Extension Upper Humidity Vent Extensions Humidity Vent Bracket Hose Clamp Large x 2 150mm Feet x 2 Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 4...
  • Page 6: Assembly

    Using a spirit level, ensure that the Combi oven is level. Adjust the foot height to level Combi oven Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 5...
  • Page 7 Place upper oven on the stacking kit (minimum four people) and secure with hose clamp Ensure the four feet sit in the locating holes Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 6...
  • Page 8 12. Attach the upper humidity vent extension to the lower vent 13. Reinstall the outer bracket extension using silicone tube and two hose clamps Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 7...
  • Page 9 Page Intentionally Left Blank Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 8...
  • Page 10: Water Connection

    The Combi oven requires unfiltered water supplied to its wash system. Water pressure must be 300-350 kPa at oven connection. This is controlled with the supplied PLV • Refer to the Stoddart Standard Filter user manual for filter setup Supplied Components (Plumbing Kit / Water Filter Kit) 1 x BWT Filter B.
  • Page 11 WITH ISOLATION VALVE (EXISTING CONNECTION) UPPER OVEN UPPER OVEN STEAM WASH GENERATION SYSTEM LOWER OVEN LOWER OVEN STEAM WASH GENERATION SYSTEM Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 10...
  • Page 12: Stoddart Supplied Reverse Osmosis Filter

    The Combi oven requires unfiltered water supplied to its wash system. Water pressure must be 300-350 kPa at oven connection. This is controlled with the supplied PLV • Refer to the Stoddart supplied RO user manual for filter setup Supplied Components (Plumbing Kit / Water Filter Kit) 1 x Ro Unit B.
  • Page 13 WITH ISOLATION VALVE (EXISTING CONNECTION) UPPER OVEN UPPER OVEN STEAM WASH GENERATION SYSTEM LOWER OVEN LOWER OVEN STEAM WASH GENERATION SYSTEM Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 12...
  • Page 14: Drainage Connection

    Secure waste pipe to the Combi oven. Securing bracket is attached to top of the Combi oven. Remove screw, reposition bracket, then secure in place with previously removed screw 25mm Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 13...
  • Page 15 Due to continuous product research and development, the information contained herein is subject to change without notice. www.stoddart.com.au www.stoddart.co.nz Page 14...
  • Page 16 Australia Service / Spare Parts Sales Tel: 1300 307 289 Tel: 1300 79 1954 Email: service@stoddart.com.au Email: sales@stoddart.com.au Email: spares@stoddart.com.au Service Request www.stoddart.com.au Australian Business Number: 16009690251 New Zealand Service / Spare Parts Sales Tel: 0800 935 714 Tel: 0800 79 1954 Email: service@stoddart.co.nz...