27

6.7EvaporatorSensor

6.7.1 Basic parameters
R(5 )=5K06±2%
6.7.2 Checking method
1.Check the connecting wiring of Defrost.Sensor is well or not, repair if it
isbroken.
The Defrost.Sensor corresponding pin No.7 and No.13 areconnectingon CN7
connector of mainboard.
2. Using a Multimeter with the ohm switch to measure the resistor of sensor,if it
is open circuit or short circuit,it means the sensor is broken, change the
sensor;If not,change the mainboard.
6.7.3 Removing the Sensor
1. Unplug the appliance.
2.Remove the four screws by screwdriver, as picture 1.
3. Unplug the terminal of the fan as picture 2.
4.Pry the holder open with pliersas picture 3.
5. remove the evaporatorsensor, as picture 4.
Picture1
Picture3
Picture2
Picture4