Hisense RS-13DJ1SCA/UGE-003 Service Manual page 30

Beverage cooler
Table of Contents

Advertisement

6.6Sensor
6.6.1 Basic parameters
R(5℃)=5K06±2%
6.6.2
Testing
method
1.Checkthatthe
cable to
isbroken.
The chamber Temp-Sensorcorresponding pin No.8 and
CN7 connector of mainboard.
2. Using a Multimeter with the ohm switch to measure the
sensor,if it is open circuit or short circuit,it means the sensor is broken,change
the sensor;If not,change the mainboard.
6.6.3 Removing the Sensor
1. Unplug the appliance.
2. Remove the cover by screwdriver as picture 1.
3. Remove the
sensor
Picture1
Picture3
thechamber
Temp-Sensorismaking contact,
by screwdriver as picture 2 and picture 3.
No.12areconnected
resistance
Picture2