Compressor - Hisense RS-13DJ1SCA/UGE-003 Service Manual

Beverage cooler
Table of Contents

Advertisement

21

6.3 Compressor

6.3.1 Basic parameters
Input voltage:115V
Input frequency:60Hz
6.3.2 Checking method
1.About 3 minutes after the last power outage, the compressor will start in 10 seconds.If it
startsunsuccessfully,cut off the refrigerator power at first, then remove the electric box
cover and check.
2.Check the
cable
between compressor and mainboardand repair if it isbroken.
3.Use a multimeter to measure voltage between pin No.1 and No.4on CN1connector of
mainboard,if the voltage equal to electric supplypower,it means the compressor is
broken,change it;If not,change themainboard.
6.3.2.1 Compressor checking
Use a multi-meter to test the resistance between C & S, M&S and M&C :
Normal range of C&S : About6.42
±
7 %Ω
Normal range of M&S : About 13.03
7 %Ω
±
Normal range of M&C : About16.61
7 %Ω
±
If the test result is not in this range then it means the inner coil has some problem
and the compressor cannot work properly.