SDongleA-05 Smart Dongle
Quick Guide (WLAN-FE)
Document Issue: 10
Part Number: 31500HMN
Release Date: 2022-06-27
Copyright © Huawei Digital Power Technologies Co., Ltd. 2022. All rights reserved.
The information in this document is subject to change without notice. Every effort has been
made in the preparation of this document to ensure accuracy of the contents, but all
statements, information, and recommendations in this document do not constitute a warranty
of any kind, express or implied.
SDongleA-05 (Dongle for short) is a smart communications expansion module that works
with Huawei inverters to implement communication between inverters and the management
system using WLAN or FE.
A Dongle can be used for device cascading using RS485 communication (inverter cascaded
or inverters cascaded with other devices). A maximum of 10 devices can be cascaded.
If cascaded inverters include a single-phase inverter or are connected to batteries, a
maximum of three inverters can be cascaded.
When multiple inverters are cascaded, only one Smart Dongle or one SmartLogger is
allowed.
1
Communication Scenario
Inverters with different appearances are used in the same communication scenario. The
inverters in this document are used as an example.
In the networking, the inverter where the Dongle is installed is the master inverter, and other
inverters are slave inverters. Slave inverters can communicate with the Dongle through
cascading.
In the communications scenario, ensure that the wireless network of the inverter and router
is not disturbed and that the signal is normal.
Master
inverter
Devices in the
Slave
dashed box are
optional.
inverter 1
Slave
inverter n
Inverter Model Requirements
Master Inverter
SUN2000-(2KTL-6KTL)-L1
SUN2000-(3KTL-20KTL)-M0
SUN2000-(3KTL-12KTL)-M1
SUN2000-(8KTL-20KTL)-M2
SUN2000-(20KTL -40KTL)-M3
2
Installation and Commissioning
1.
Install the Dongle.
WLAN Communication
Inverter USB port
FE Communication
You are advised to use a CAT 5E outdoor shielded network cable (outer diameter < 9 mm;
internal resistance ≤ 1.5 Ω/10 m) and shielded RJ45 connectors.
LED
Operation
Color
N/A
Yellow (blinking
green and red
simultaneously)
Red
Installing
the Dongle
Red
Blinking red and
green
alternatively
Before setting parameters, ensure that the AC and DC side of the inverter has been powered on.
2.
Install the FusionSolar app. Perform
the Setup wizard operations. If you
have performed such operations, skip
this step. If not, you can scan the QR
code below to obtain the app quick
guide which describes the Setup
wizard operations.
LED Indicator
Operation
Color
Green
Router
connection
settings
Red
Green
Management
Red
system
settings
Green
In areas (such as the UK) where the FusionSolar app is not available, or
when a third-party management system is used, only the SUN2000 app
can be used for commissioning. This document uses the FusionSolar app
as an example to describe the commissioning method. For the SUN2000
app, perform operations as required.
To obtain the SUN2000 App, scan the QR code or search for "SUN2000"
in Huawei AppGallery, download the latest installation package, and
install the SUN2000 app by following the instructions. The SUN2000 app
version should be 3.2.00.002 (Android) or later.
Performance Parameters
Model on the Nameplate
Maximum Number of Devices
Network Port
Encryption Mode
Installation Mode
Indicator
Dimensions (W x H x D)
Net Weight
Ingress Protection Rating
Typical Power Consumption
Standard and Frequency Band
Operating Temperature
Relative Humidity (Non-
condensing)
Storage Temperature
Highest Altitude
3
Obtaining Documentation
You can obtain the latest version of this document by scanning the following QR codes.
Chinese
Türkçe
App
Router
RS485 communication scenario
Limited Number
Maximum number
of devices that can
be connected to
the Dongle
If devices are connected to the 485B2 and 485A2 ports of
the master inverter, the devices are not included as cascaded
devices.
Status
Off
Steady on
Blinking at
short
intervals (on
for 0.2s and
then off for
0.2s)
Steady on
Blinking at
long
intervals (on
for 1s and
then off for
1s)
Status
Blinking at long
intervals (on for 0.5s
and then off for 0.5s)
Blinking at short
intervals (on for 0.2s
and then off for 0.2s)
Steady on
Blinking at long
intervals (on for 1s
and then off for 1s)
Blinking at short
intervals (on for 0.2s
and then off for 0.2s)
SDongleA-05
10 (Inverters are connected with each other over RS485.)
10/100M Ethernet port
Not encrypted, WPA, WPA2, WPA/WPA2
Plug-and-play (applicable to inverters only)
LED
146 mm x 48 mm x 33 mm
90 g
IP65
2.5 W
802.11b, 802.11g, 802.11n
2.412 GHz to 2.484 GHz
–30ºC to +65ºC
5%–95% RH
–40ºC to +70ºC
4000 m
English
Português
Huawei Digital Power Technologies Co., Ltd.
Management system
Number of devices in the
Number of
inverters
10
SUN2000-(2KTL-6KTL)-L1
SUN2000-(3KTL-20KTL)-M0
SUN2000-(3KTL-12KTL)-M1
SUN2000-(8KTL-20KTL)-M2
SUN2000-(20KTL -40KTL)-M3
SUN2000-29.9KTL/36KTL
SUN2000-33KTL-A
SUN2000-50KTL/60KTL-M0
Inverter USB port
Remarks
Description
The Dongle is not secured or is not
powered on.
The Dongle is secured and powered
on.
Normal
The parameters for connecting to
the router are to be set.
The Dongle is faulty. Replace the
Dongle.
No communication with the
inverter
• Remove and insert the Dongle.
Abnormal
• Check whether inverters match
• Connect the Dongle to other
FusionSolar app
Remarks
Description
Normal
Connecting to the router
Failed to connect to the router.
Check whether the parameters for
Abnormal
connecting the Dongle to the router
are properly set. If not, set the
parameters correctly.
Successfully connected to the
Normal
management system.
Failed to connect to the
management system. Check whether
the parameters for connecting
Abnormal
inverters to the management system
are properly set. If not, set the
parameters correctly.
The inverter is communicating with
Normal
the management system through
the Dongle.
Deutsch
Italiano
Huawei Digital Power Antuoshan Headquarters
Actual Number
Number of other
devices (such as Smart
slave
Power Sensor and
energy storage devices)
n ≤ 9
Slave Inverter
LED indicator
the Dongle.
inverters. Check whether the
Dongle or the USB port of the
inverter is faulty.