ERROR CODE
Err 008
(Overheating of
power board)
2. Damaged NTC sensor on PB
Err 010
(Self-clean heat
up fail)
Err 014
(Cooktop
activation
during active
Self Clean
function)
Err 015
(Zero cross
failure on power
board)
ERROR CODE TRIGGER
1. Detected temperature on
PB NTC sensor above 230°F /
100°C
1. Self Clean set temperature
not reached in sufficient time
1. Cooktop is activated during
Self Clean for more than one
minute
2. Self Clean is activated after
cooktop is active
3. Damaged wiring
4. Damaged PB
1. Zero-Cross failure on PB
2. Damaged PB
DESCRIPTION
Error is displayed and
all the oven functions
must stop. When
error is cleared user
can again can the
appliance.
Error is displayed and
Self Clean function
must stop. When
error is cleared user
can again can the
appliance and Self
Clean function.
SW must sense error
when it is detected.
When Error 14 is
detected, Self Clean
function must stop and
error is displayed on
UI.
Error is displayed
when it is detected, all
oven function stop and
user cannot use the
appliance until the error
is cleared.
11
Error Codes
TEST PROCEDURE
With a heating gun heat resistor
R100 and resistor R145
Pull out PT1000 sensor from
oven. Leave it at ambient
temperature. Run Self clean
function.
Activate Cooktop switches 1-5
Disconnect OP1 pin 4 from power
board. For additional ZC tests

Hide quick links: