T181S.
SLIDING GATE CONTROL UNIT. 230 VAC POWER SUPPLY. 433.92 MHz FREQUENCY . 100 STORABLE CODES.
ON
1
2
3 4 5 6 7 8 9 10 11 12
RC1
RC2
R1
R2
REMOTE
R3
R4
A
TIME
B
C
1
2
3
4
5
6
INPUTS
1
2
3
4
5
6
INTERNAL
RECEIVER
S1 S2 S3
BOARD STATUS:
STAND BY, GATE CLOSED
GATE IN OPENING OR CLOSING PHASE, GATE OPEN
CONTROL BOARD IN PROGRAMMING PHASE
PHOTOCELLS TEST ERROR
MOTOR TEST ERROR: CONNECTION ERROR
OR MOTOR OVERHEATING
PROGRAMMING ERROR
DIP 1 OFF / DIP 2 OFF
1
2
3 4 5 6 7 8 9 10 11 12
DIP 3 OFF
DISABLED
1
2
3 4 5 6 7 8 9 10 11 12
DIP 4 OFF
DISABLED.
THE MOTOR STARTS AT THE POWER
1
2
3 4 5 6 7 8 9 10 11 12
LEVEL SET BY DIP 1 AND DIP 2.
DIP 5 OFF
6 SECONDS
3 4 5 6 7 8 9 10 11 12
1
2
DIP 6 OFF
MOTOR TEST AND PHOTOCELLS TEST
DISABLED
1
2
3 4 5 6 7 8 9 10 11 12
DIP 7 OFF / DIP 8 OFF
AUTOMATIC
CLOSURE
1
2
3 4 5 6 7 8 9 10 11 12
DIP 9 OFF
N.C. LIMIT SWITCHES CONTACT NORMALLY
CLOSE
1
2
3 4 5 6 7 8 9 10 11 12
DIP 10 OFF
N.C. INPUTS ENABLED
1
2
3 4 5 6 7 8 9 10 11 12
DIP 11 OFF
TERMINAL 1: START FUNCTION
1
2
3 4 5 6 7 8 9 10 11 12
TERMINAL 7: PEDESTRIAN FUNCTION
DIP 12 OFF
DISABLED
1
2
3 4 5 6 7 8 9 10 11 12
EXTERNAL
RECEIVER
7
7
8
9 10 11 12
DIP 1 ON / DIP 2 OFF
40%
1
2
3 4 5 6 7 8 9 10 11 12
DIP 7 ON / DIP 8 OFF
1
2
3 4 5 6 7 8 9 10 11 12
DISABLE NOT WIRED N.C. INPUTS
START AND PEDESTRIAN / OPEN AND CLOSE
GROUND
2A FUSE
N
L
230 VAC
x
13 14 15
MOTOR
LAMP 230 VAC
LEDs:
S1.S2.S3. CONTROL BOARD STATUS LEDS
RC1.RC2.R1.R2.R3.R4. RADIO LEDS
RC1. SHOWS THAT A SIGNAL HAS BEEN RECEIVED FROM THE INTERNAL RADIO RC1
RC2. SHOWS THAT A SIGNAL HAS BEEN RECEIVED FROM THE EXTERNAL RADIO RC2
R1.START: INDICATES THAT A START BUTTON ON THE REMOTE HAS BEEN PRESSED
R2.STOP: INDICATES THAT A STOP BUTTON ON THE REMOTE HAS BEEN PRESSED
R3. PEDESTRIAN: SHOWS THAT A START PEDESTRIAN BUTTON ON THE REMOTE
HAS BEEN PRESSED
R4. OUT1 ON/OFF: SHOWS THAT A OUT1 BUTTON ON THE REMOTE HAS BEEN
PRESSED
A. C. PROGRAMMING LEDS
B.
1.2.3.4.5.6.7. INPUT LEDS
MOTOR POWER
60%
1
2
3 4 5 6 7 8 9 10 11 12
SLOW DOWN
1
2
3 4 5 6 7 8 9 10 11 12
SOFT START
1
2
3 4 5 6 7 8 9 10 11 12
PEDESTRIAN WORKING TIME
3 4 5 6 7 8 9 10 11 12
1
2
TESTS
1
2
3 4 5 6 7 8 9 10 11 12
MODES
COMMUNITY
MODE +
AUTOMATIC
1
2
3 4 5 6 7 8 9 10 11 12
CLOSURE
LIMIT SWITCHES
1
2
3 4 5 6 7 8 9 10 11 12
1
2
3 4 5 6 7 8 9 10 11 12
1
2
3 4 5 6 7 8 9 10 11 12
MOTOR BREAK
1
2
3 4 5 6 7 8 9 10 11 12
TERMINAL BLOCK:
1. START N.O.
2. STOP N.C.
3. EXTERNAL PHOTOCELL N.C.
4. INTERNAL PHOTOCELL N.C.
5. CLOSING LIMIT SWITCH N.C. / N.O.
6. OPENING LIMIT SWITCH N.C. / N.O.
7. PEDESTRIAN N.O.
8. +VDC / COMMON
9. PHOTOCELLS TEST
10. GND
11.12. FLASHING LAMP
13. MOTOR CLOSE
14. MOTOR COMMON
15. MOTOR OPEN
20.X.19. 230 VAC
DIP-SWITCHES:
1.2. MOTOR POWER
3. SLOW DOWN
4. SOFT START
5. PEDESTRIAN WORKING TIME
6. TESTS
7.8. MODES
9. LIMIT SWITCHES
10. DISABLE NOT WIRED N.C. INPUTS
11. START AND PEDESTRIAN / OPEN AND CLOSE
12. MOTOR BRAKE
AUXILIARY OUTPUTS:
OUT1. ENABLED/DISABLED VIA REMOTE (R4)
OUT2. COURTESY LIGHT / ENABLED DURING
OPENING FOR 3 MINUTES
DIP 1 OFF / DIP 2 ON
80%
1
2
ENABLED.
THE MOTOR WORKS AT THE MAXIMUM
POWER (100%) DURING THE SLOW PHASE.
ENABLED.
1.2. SECONDS. THE MOTOR POWER
INCREASES GRADUALLY TILL IT REACHES ITS
MAX VALUE.
12 SECONDS
MOTOR TEST AND PHOTOCELLS TEST ARE
PERFORMED BEFORE ANY GATE MOVEMENT
DIP 7 OFF / DIP 8 ON
STEP-BY-STEP
MODE
1
2
3 4 5 6 7 8 9 10 11 12
N.O. LIMIT SWITCHES CONTACT NORMALLY
OPEN
NOT WIRED NC INPUTS DISABLED. WHEN A
N.C. INPUT IS WIRED, IT IS AUTOMATICALLY
ENABLED
TERMINAL 1: OPEN FUNCTION
TERMINAL 7: CLOSE FUNCTION
ENABLED. MOTOR BREAK ON FOR 0.2
SECONDS IF GATE REACHES LIMIT SWITCH
WITHOUT SLOWING DOWN.
ON
1
2
3 4 5 6 7 8 9 10 11 12
OFF
DIP 1 ON / DIP 2 ON
100%
3 4 5 6 7 8 9 10 11 12
DIP 3 ON
DIP 4 ON
DIP 5 ON
DIP 6 ON
DIP 7 ON / DIP 8 ON
STEP-BY-STEP
MODE +
AUTOMATIC
CLOSURE
DIP 9 ON
DIP 10 ON
DIP 11 ON
DIP 12 ON