Indicators - Mitsubishi Electric XD8500 User Manual

Table of Contents

Advertisement

Indicators

This projector has 5 indicators, each of which shows the operation condition of the projector.
The following offer solutions to possible problems. If these problems persist, turn the projector off and consult your
dealer.
 POWER, STATUS, and FILTER: The current condition is indicated.
POWER STATUS
Normal
Steady red
condition
Steady green
Blinking green/
red
Abnormal
condition
Steady red
or
Blinking orange
Steady green
*1: Status of either or both of the indicators.
LAMP 1, LAMP 2: The condition of each lamp is indicated.
LAMP 1 / LAMP 2 CONDITION
Normal
Blinking green
condition
Steady green
Blinking red
or
Replacement
Blinking green/red
Steady red
Abnormal
condition
Blinking orange
*2: Duration when LAMP MODE of the INSTALLATION 1 menu is set to LOW. When it is set to STANDARD, this duration will be shorted.
*3: When LAMP MODE is set to STANDARD, this duration will be shorted up to 2000 hours.
FILTER indicator
STATUS indicator
FILTER CONDITION
Power standby or cooling
Off
Off
The power is on (Normal condition)
Off
Off
• Any of the lamp cover and filter cover
is open.
Off
Off
Abnormal
Steady
*1
or
Blinking
*1
Abnormal temperature
• The vents are clogged with dust or
dirt.
• The room temperature is high.
Off
• The filter is dirty.
• When the lamp is illuminating, it is in the
warmup mode. (You cannot turn off the
power.)
• When the lamp is off, it is in the cooling
mode. (You cannot turn on the power.)
The lamp is illuminating.
Lamp operation time warning. (Total lamp
operation time reached 3000 hours
Lamp operation time warning. (Total lamp
operation time reached 4000 hours
The protection circuit is working or the lamp
is in an abnormal condition.
When only one lamp fails:
• In the case that LAMP SELECT is set to
DUAL, only the normal lamp illuminates
(the intensity of one lamp is obtained).
• In the case that LAMP SELECT is set to
SINGLE, LAMP 1, or LAMP 2, only the
normal lamp illuminates (the lamp isn't
switched).
POWER indicator
LAMP 1 indicator
LAMP 2 indicator
POSSIBLE SOLUTION
Replace the light source lamp indicated by the
.)
illuminating or blinking indicator.
*2
Change with a new lamp if this problem
recurs.
.)
*2*3
When both indicators blink, wait until the
indicators stop blinking and then press the
POWER button. If the light source lamps don't
illuminate even after you perform the above
operation several times, unplug the power cord
from the wall outlet and contact your dealer.
To illuminate the failed lamp again when either
indicator blinks, turn off the power and wait until
the indicator stops blinking and then press the
POWER button. If the light source lamp doesn't
illuminate even after you perform the above
operation several times, unplug the power cord
from the wall outlet and contact your dealer.
EN-73
POSSIBLE SOLUTION
The lamp condition is indicated by
the LAMP indicators.
• Close all the covers.
Contact your dealer.
• Clean the vents.
• Relocate the projector to a cooler
place.
• Clean the filter. (See page 67.)

Advertisement

Table of Contents
loading