Influx Technology ReXgen Air User Manual

Hide thumbs Also See for ReXgen Air:

Advertisement

Quick Links

User Guide
ReXgen Air - Manual
www.influxtechnology.com

Advertisement

Table of Contents
loading

Summary of Contents for Influx Technology ReXgen Air

  • Page 1 User Guide ReXgen Air - Manual www.influxtechnology.com...
  • Page 2: About This Manual

    This document provides a brief idea of the usage, safety precautions, installation procedures and operation of the Influx ReXgen Air. This document is intended for professional engineers and academic researchers, allowing them to understand the concept of operating the device and integrating this knowledge into systems with components of other manufacturers.
  • Page 3: Safety Instructions

    ReXgen Air: Product Manual SAFETY INSTRUCTIONS Always ensure that the device is installed, connected, and commissioned by a qualified professional ▪ following all safety norms. Disconnect the device completely before handling it and disconnect any independently supplied ▪ output load circuits.
  • Page 4: Table Of Contents

    ReXgen Air: Product Manual Table of Contents ABOUT THIS MANUAL ............................. 1 DISCLAIMER ..............................1 COPYRIGHT & LICENSE AGREEMENT ......................1 CONTACT ADDRESS ............................1 SAFETY INSTRUCTIONS ........................... 2 OVERVIEW OF THE DEVICE ........................5 Key features..............................5 GENERAL INFORMATION ........................ 7 1.1.1...
  • Page 5 ReXgen Air: Product Manual CONNECTING THE DEVICE ......................17 3.1.1 POWER ............................18 3.1.2 CAN/CAN FD ..........................18 3.1.3 ANALOG & DIGITAL INPUT ......................18 3.1.4 USB ............................... 18 SOFTWARE INSTALLATION ......................19 DRIVER INSTALLATION ........................21 FIRMWARE UPDATE ......................... 22 ANNEXURES ............................
  • Page 6: Overview Of The Device

    ReXgen Air: Product Manual OVERVIEW OF THE DEVICE CAN to Cloud This chapter gives an overview of the device, its operating elements and functions, and its intended use. Along with the free, user-friendly configuration software, the standalone ReXgen logger comes with the...
  • Page 7 • Free powerful graphic interface application tool ReXdesk provided. *Will be available via software update next quarter *x1 micro -USB cable to be supplied with any quantity of ReXgen Air purchased. *Works with AT&T and T-Mobile in USA Available Models...
  • Page 8: General Information

    ReXgen Air: Product Manual 1.1 GENERAL INFORMATION 1.1.1 DEVICE ELEMENTS 1 – Channel LED 1 6 – FAKRA C connector for GNSS 2 – Channel LED 2 7 – Nano Sim Slot 3 – Channel LED 3 8 – FAKRA D connector for LTE 4 –...
  • Page 9: Technical Specification

    ReXgen Air: Product Manual 1.1.3 TECHNICAL SPECIFICATION Functions ReXgen Air Up to 4 x CAN/CAN FD ISO 11898-1: Compliant with CAN (up to 1 Mbit/s) ISO & Bosch CAN FD (up to 8 Mbit/s) CAN Interfaces Conforms to CAN protocol version 2.0 - part A, B Up to 20000 mps Meets the requirements of ISO 11898-2:2016 &...
  • Page 10 ReXgen Air: Product Manual Triggering Trigger on CAN ID, CAN Signal, Digital Input. Trigger on DM1 counter. File Format Supported RXD, RXE, ASAM MDF (.mf4), CSV, MATLAB, ASC, BLF Data Transfer Protocol FTPS and Amazon S3 Security Functions Encryption of data logs, Locking of device.
  • Page 11: Intended Use

    Power Down Mode: <2 mA 1.1.5 INTENDED USE The Influx ReXgen Air supports up to 4 CAN/CAN FD buses. It has GNSS, IMU and is specially designed to become a part of your fleet during production. Works on LTE CAT1, making it a cost-effective solution.
  • Page 12: Software

    ReXgen Air with custom baud rates and modify advanced bit timings. ReXdesk also enables the user to configure ReXgen Air with CAN & J1939 filters. All logged data is saved to the secure embedded memory. The user can configure triggers based on CAN IDs, parameter values &...
  • Page 13: Recording Accelerometer & Gyroscope Data

    The contents below specify the conditions to be ensured for the operation of ReXgen Air. SIM CARD INSERTION When inserting the sim card in a ReXgen Air device, ensure that you open the lid on the SIM slot correctly and carefully. Mishandling the SIM slot lid can damage the device and further damage the SIM card inside.
  • Page 14 ReXgen Air: Product Manual GROUNDING Since it is not required to provide a common ground between nodes, it is possible to have ground offsets. Each node may observe different single-ended bus voltages (common mode bus voltages) while maintaining the same differential voltage. Operating a CAN system with large ground offsets can increase electromagnetic emissions.
  • Page 15: Enclosure

    ReXgen Air: Product Manual MOUNTING Always ensure to mount the device in a way that minimises vibration exposure and accounts for the IP rating of the device. ReXgen Air is supplied with four screws to assist you with mounting. ANTENNA WARNING An external active FAKRA C or FAKRA D antenna with a supply voltage of 3V is required for GNSS and LTE data logging.
  • Page 16 ReXgen Air: Product Manual 2.2.3.1 CONNECTOR PIN DETAILS 24-pin Molex Mini50 Connector PIN No PIN Function Optional Pin 1 RelayOut0 (Optional) Pin 2 DigIn0 Pin 3 AnalogGnd Pin 4 Adc1 Pin 5 Clamp-15 Pin 6 CAN0-L Pin 7 CAN1-L Pin 8...
  • Page 17 ReXgen Air: Product Manual Male 25 pin Standard D Type connector (Mini 50 to D Sub 25 cable Sold separately). Pin No Pin Function Pin 3 CAN Bus 3 Low Signal (Available only on 4x CAN Model) Pin 4 Analog Input 1 - do not apply voltages outside of the -10 to +10V range...
  • Page 18: Indicator Elements - Led's

    ReXgen Air: Product Manual 2.2.3.2 GNSS ANTENNA CONNECTOR ReXgen Air uses a FAKRA C connector (Blue) for the GNSS and a FAKRA D connector (Bordeaux) for the LTE antenna. 2.2.4 INDICATOR ELEMENTS – LED'S 4 LEDs are installed on ReXgen Air for indicating the CAN/CAN FD logging activity.
  • Page 19: Power

    +34V 3.1.2 CAN/CAN FD ReXgen Air can be interfaced to the CAN/CAN FD bus from which data is to be logged using D- Sub 9 connector A or connector B. The CAN-high and CAN-low from the vehicle or machine terminals must match the CAN-high and CAN-low terminal of the ReXgen Air. ReXgen Air should be configured with the same baud rate as the device to which it is interfaced.
  • Page 20: Software Installation

    ReXgen Air: Product Manual 3.2 SOFTWARE INSTALLATION Download the latest version of our ReXdesk software from the Influx Technology website. Notes •Before proceeding with the installation, please ensure that you have acquired administrative privileges. Make sure you have installed the Microsoft Visual C++ Redistributable.
  • Page 21 ReXgen Air: Product Manual • Select the folder in which you wish to install the software; it is preferred to use the default location. • Select the preference for computer user installation to determine which computer users will access the ReXdesk software.
  • Page 22: Driver Installation

    ReXgen Air: Product Manual 3.3 DRIVER INSTALLATION To install the ReXgen Air driver, locate the ReXgen Air Drivers installer from the start menu. Notes •Before proceeding with the installation, please ensure that you have acquired administrative privileges. Run the ReXgenInstaller.exe file.
  • Page 23: Firmware Update

    ReXgen Air: Product Manual • Click 'Finish' to close the window. The ReXgen Air driver is now successfully installed on your system. 3.4 FIRMWARE UPDATE All newly released firmware updates will be available in www.influxtechnology.com Firmware can be updated using the Reflash option in the ReXdesk software.
  • Page 24: Annexures

    ReXgen Air: Product Manual 4. ANNEXURES This chapter contains technical data and certificates. 4.1 DIGITAL INPUT FUNCTION The Digital Input Output pins will consider voltages below 0.8V as 'low' and above 2.5V as 'high'. Examples of how you could utilise the I/O pins if configured as inputs are shown below: 4.2 THE WAKE UP PIN...
  • Page 25: Can Overview

    ReXgen Air: Product Manual 4.3 CAN OVERVIEW CAN stands for "Controller Area Network" and is defined in the ISO 11898 specification. The Controller Area Network (CAN, also known as CAN Bus) is a vehicle bus standard designed to allow electronic control units and devices to communicate in applications without a host computer. As an alternative...
  • Page 26 ReXgen Air: Product Manual Maximum length achievable: - 500 metres at a lower speed of 125 Kbps. • The bus should be terminated at both ends with 120-ohm resistance. • Removal of one node will not affect the communication in the bus.
  • Page 27 Influx Technology Headquaters Office Suite 22, Building 03 Millbrook Proving Ground, Station Lane Millbrook Bedford MK45 2JQ Telephone: +44 (0) 1525 842504 Sales: sales@influxtechnology.com Influx Big Data Solutions Pvt Ltd 3358E, 13th Main Rd, HAL 2nd Stage, Doopanahalli, Indiranagar, Bengaluru, 560008...

Table of Contents