ReXgen 2: Product Manual SAFETY INSTRUCTIONS Always ensure that the device is installed, connected, and commissioned by a qualified professional by ▪ following all safety norms. Disconnect the device completely before handling it and disconnect any independently supplied ▪ output load circuits.
ReXgen 2: Product Manual Table of Contents ABOUT THIS MANUAL ............................. 1 DISCLAIMER ..............................1 COPYRIGHT & LICENSE AGREEMENT ......................1 CONTACT ADDRESS ............................1 SAFETY INSTRUCTIONS ........................... 2 OVERVIEW OF THE DEVICE ........................5 GENERAL INFORMATION ........................ 6 1.1.1 DEVICE ELEMENTS ..........................6 1.1.2 PRODUCT DRAWINGS ........................
Page 5
ReXgen 2: Product Manual 3.1.1 POWER ............................. 17 3.1.2 CAN / CAN FD ..........................17 3.1.3 ANALOG & DIGITAL INPUT......................17 3.1.4 USB ..............................18 SOFTWARE INSTALLATION ......................18 DRIVER INSTALLATION ........................20 ReXgen2 as a J2534 tool ......................... 22 FIRMWARE UPDATE ........................
ReXgen 2: Product Manual OVERVIEW OF THE DEVICE This chapter overviews the device, its operating elements and functions, and its intended use. Along with the free, user-friendly configuration software, the standalone ReXgen2 logger comes with the following advantages: Extreme level of compactness – pocket size ▪...
ReXgen 2: Product Manual 1.1.3 TECHNICAL SPECIFICATION Functions ReXgen 2 ReXgen 2 IMU 2 x CAN/CAN FD ISO 11898-1: Compliant with CAN (up to 1 Mbit/s) ISO & Bosch CAN FD (up to 8 Mbit/s) CAN Interfaces Conforms to CAN protocol version 2.0 - part A, B Max 20000 mps Meets the requirements of ISO 11898-2:2016 &...
ReXgen 2: Product Manual Data Storage Format FAT32, Log files accessible via ReXdesk Software File Format Supported ASAM MDF (.mf4), CSV, MATLAB, ASC, BLF Data Logger Configuration Supplied with Influx ReXdesk configuration software, XML based Analog Input Number of channels...
Influx Technology assumes no liability for damages caused by normal wear, installation errors, or operating or maintenance faults. Applicable also when the user modifies the devices, any accessories, or the Software without the prior approval of Influx Technology. 1.1.7 CONFORMITY For detailed information on the respective tests, see Chapter Certifications.
ReXgen 2: Product Manual 2. HARDWARE & FUNCTIONALITY In this chapter, you will find Information on the device functionality and hardware. 2.1 FUNCTIONS FUNCTION ReXgen2 (INF 2110/1) ReXgen2 IMU (INF 2112/3) CAN/CAN FD Data Logging Digital and Analog Input LIN Data Logging...
ReXgen 2: Product Manual record the data determined from the input functions, and it can be used for creating triggers for starting and stopping logging. 2.2 HARDWARE 2.2.1 INSTALLATION The contents below specify the conditions to be ensured for the operation of ReXgen2.
ReXgen 2: Product Manual MOUNTING WARNING Always mount the device in a way that minimises vibration exposure and accounts for the IP rating of the device. ReXgen2 is supplied with four screws to assist you with the mounting process. ANTENNA An external active antenna with a supply voltage of 3V is required for GNSS data logging.
Page 15
ReXgen 2: Product Manual 2.2.3.1 CONNECTOR PIN DETAILS There are two connectors, a male and female 9-pin Standard D-Type connector. Channel 0 Connector PIN No DB9(Male with Nuts) PIN Function PWR/CAN0/Digital/LIN Pin 1 Digital 1 Pin 2 CAN/CAN FD 0 - Low...
ReXgen 2: Product Manual Notes •Connector needs to be tightened properly to make a proper connection, ensuring reliable operation. •Each end of the CAN/CAN FD bus must be terminated with a 120 Ohm resistor across CAN H & CAN L.
ReXgen 2: Product Manual 2.2.5 ACCESSORIES Accessory Part Number Description USB Isolator INF4311 External isolator for the USB. CAN Terminator INF4310 120 Ohms D Sub 9 CAN Terminator. OBD II TYPE-B Cable to 9-way D-Sub INF4103 Cable for connecting to vehicle OBD port.
ReXgen 2: Product Manual 3. GETTING STARTED 3.1 CONNECTING THE DEVICE ATTENTION! • A qualified technician must install, connect, and commission the device. • Ensure the power supply is disconnected before connecting the device. • Only use components from the starter kits, or the accessories supplied.
USB. The device is supplied with a standard Micro USB cable. Please note that the USB is not isolated, and an isolator can be purchased separately. 3.2 SOFTWARE INSTALLATION Download the latest version of our ReXdesk Software from the Influx Technology website. Notes •Before proceeding with the installation, please ensure that you have acquired administrative privileges.
Page 20
ReXgen 2: Product Manual point). • Select the folder where you wish to install the Software; it is preferred to use the default location. • Select the preference for computer user installation to determine which computer users will have access to the ReXdesk Software.
ReXgen 2: Product Manual • Once the installation is complete, this window will appear. • Click 'Close' to close the window. ReXdesk is now successfully installed on your system. 3.3 DRIVER INSTALLATION To install the ReXgen2 driver, locate the ReXgen2 Drivers installer from the start menu.
Page 22
ReXgen 2: Product Manual • Click 'Next' to continue installing the ReXgen device driver on your system. • To cancel the installation at this stage, click 'Cancel'. (No software will have been installed on the system at this point.) •...
ReXgen 2: Product Manual 3.4 ReXgen2 as a J2534 tool • Download the J2534 driver and execute the file. • Click 'Install.' After successful installation, Windows Registry should contain J2534 ReXgen properties. 3.5 FIRMWARE UPDATE All newly released firmware updates will be available on www.influxtechnology.com...
ReXgen 2: Product Manual 4. ANNEXURES This chapter contains technical data and certificates. 4.1 DIGITAL INPUT FUNCTION The Digital Input Output pins will consider voltages below 0.8V to be low and above 2.5V to be high. Below are examples of how you could utilise the I/O pins if configured as inputs.
ReXgen 2: Product Manual 4.3 CAN OVERVIEW CAN stands for "Controller Area Network" and is defined in the ISO 11898 specification. The Controller Area Network (CAN, also known as CAN Bus) is a vehicle bus standard designed to allow electronic control units and devices to communicate in applications without a host computer. As an...
Page 29
ReXgen 2: Product Manual The maximum length achievable is 500 metres at a lower speed of 125 Kbps. • The bus should be terminated at both ends with 120-ohm resistance. • • Removal of one node will not affect the communication in the bus.
Page 30
Influx Technology Headquaters Office Suite 22, Building 03 Millbrook Proving Ground, Station Lane Millbrook Bedford MK45 2JQ Telephone: +44 (0) 1525 842504 Sales: sales@influxtechnology.com Influx Big Data Solutions Pvt Ltd 3358E, 13th Main Rd, HAL 2nd Stage, Doopanahalli, Indiranagar, Bengaluru, 560008...