Advertisement

Quick Links

User Guide
ReXgen 2- Manual
www.influxtechnology.com

Advertisement

Table of Contents
loading

Summary of Contents for Influx Technology ReXgen 2

  • Page 1 User Guide ReXgen 2- Manual www.influxtechnology.com...
  • Page 2: About This Manual

    The content of this document, including all brands and trademarks and possibly protected by third-party rights, are subject to the terms of the valid trademark law and intellectual property rights of their respective registered owner. © 2020 INFLUX TECHNOLOGY. All rights reserved. CONTACT ADDRESS Influx Technology Ltd...
  • Page 3: Safety Instructions

    ReXgen 2: Product Manual SAFETY INSTRUCTIONS Always ensure that the device is installed, connected, and commissioned by a qualified professional by ▪ following all safety norms. Disconnect the device completely before handling it and disconnect any independently supplied ▪ output load circuits.
  • Page 4: Table Of Contents

    ReXgen 2: Product Manual Table of Contents ABOUT THIS MANUAL ............................. 1 DISCLAIMER ..............................1 COPYRIGHT & LICENSE AGREEMENT ......................1 CONTACT ADDRESS ............................1 SAFETY INSTRUCTIONS ........................... 2 OVERVIEW OF THE DEVICE ........................5 GENERAL INFORMATION ........................ 6 1.1.1 DEVICE ELEMENTS ..........................6 1.1.2 PRODUCT DRAWINGS ........................
  • Page 5 ReXgen 2: Product Manual 3.1.1 POWER ............................. 17 3.1.2 CAN / CAN FD ..........................17 3.1.3 ANALOG & DIGITAL INPUT......................17 3.1.4 USB ..............................18 SOFTWARE INSTALLATION ......................18 DRIVER INSTALLATION ........................20 ReXgen2 as a J2534 tool ......................... 22 FIRMWARE UPDATE ........................
  • Page 6: Overview Of The Device

    ReXgen 2: Product Manual OVERVIEW OF THE DEVICE This chapter overviews the device, its operating elements and functions, and its intended use. Along with the free, user-friendly configuration software, the standalone ReXgen2 logger comes with the following advantages: Extreme level of compactness – pocket size ▪...
  • Page 7: General Information

    ReXgen 2: Product Manual 1.1 GENERAL INFORMATION 1.1.1 DEVICE ELEMENTS 1 – External GNSS antenna connector. 5 – Mounting Holes. 2 – Micro USB connector. 6 – Channel 1 Connector. 3 – Channel 1 LED. 7 – Channel 0 Connector.
  • Page 8: Technical Specification

    ReXgen 2: Product Manual 1.1.3 TECHNICAL SPECIFICATION Functions ReXgen 2 ReXgen 2 IMU 2 x CAN/CAN FD ISO 11898-1: Compliant with CAN (up to 1 Mbit/s) ISO & Bosch CAN FD (up to 8 Mbit/s) CAN Interfaces Conforms to CAN protocol version 2.0 - part A, B Max 20000 mps Meets the requirements of ISO 11898-2:2016 &...
  • Page 9: Electrical Data

    ReXgen 2: Product Manual Data Storage Format FAT32, Log files accessible via ReXdesk Software File Format Supported ASAM MDF (.mf4), CSV, MATLAB, ASC, BLF Data Logger Configuration Supplied with Influx ReXdesk configuration software, XML based Analog Input Number of channels...
  • Page 10: Intended Use

    Influx Technology assumes no liability for damages caused by normal wear, installation errors, or operating or maintenance faults. Applicable also when the user modifies the devices, any accessories, or the Software without the prior approval of Influx Technology. 1.1.7 CONFORMITY For detailed information on the respective tests, see Chapter Certifications.
  • Page 11: Device Kit

    ReXgen 2: Product Manual 1.2 DEVICE KIT 1.2.1 HARDWARE Packaging will contain the following components: INF 2110/INF 2111 1x Rexgen2 with integrated cable ▪ 1x Micro USB ▪ INF 2112/INF 2113 1x Rexgen2 with integrated cable ▪ 1x Micro USB ▪...
  • Page 12: Hardware & Functionality

    ReXgen 2: Product Manual 2. HARDWARE & FUNCTIONALITY In this chapter, you will find Information on the device functionality and hardware. 2.1 FUNCTIONS FUNCTION ReXgen2 (INF 2110/1) ReXgen2 IMU (INF 2112/3) CAN/CAN FD Data Logging Digital and Analog Input LIN Data Logging...
  • Page 13: Hardware

    ReXgen 2: Product Manual record the data determined from the input functions, and it can be used for creating triggers for starting and stopping logging. 2.2 HARDWARE 2.2.1 INSTALLATION The contents below specify the conditions to be ensured for the operation of ReXgen2.
  • Page 14: Enclosure

    ReXgen 2: Product Manual MOUNTING WARNING Always mount the device in a way that minimises vibration exposure and accounts for the IP rating of the device. ReXgen2 is supplied with four screws to assist you with the mounting process. ANTENNA An external active antenna with a supply voltage of 3V is required for GNSS data logging.
  • Page 15 ReXgen 2: Product Manual 2.2.3.1 CONNECTOR PIN DETAILS There are two connectors, a male and female 9-pin Standard D-Type connector. Channel 0 Connector PIN No DB9(Male with Nuts) PIN Function PWR/CAN0/Digital/LIN Pin 1 Digital 1 Pin 2 CAN/CAN FD 0 - Low...
  • Page 16: Indicator Elements - Led's

    ReXgen 2: Product Manual Notes •Connector needs to be tightened properly to make a proper connection, ensuring reliable operation. •Each end of the CAN/CAN FD bus must be terminated with a 120 Ohm resistor across CAN H & CAN L.
  • Page 17: Accessories

    ReXgen 2: Product Manual 2.2.5 ACCESSORIES Accessory Part Number Description USB Isolator INF4311 External isolator for the USB. CAN Terminator INF4310 120 Ohms D Sub 9 CAN Terminator. OBD II TYPE-B Cable to 9-way D-Sub INF4103 Cable for connecting to vehicle OBD port.
  • Page 18: Connecting The Device

    ReXgen 2: Product Manual 3. GETTING STARTED 3.1 CONNECTING THE DEVICE ATTENTION! • A qualified technician must install, connect, and commission the device. • Ensure the power supply is disconnected before connecting the device. • Only use components from the starter kits, or the accessories supplied.
  • Page 19: Usb

    USB. The device is supplied with a standard Micro USB cable. Please note that the USB is not isolated, and an isolator can be purchased separately. 3.2 SOFTWARE INSTALLATION Download the latest version of our ReXdesk Software from the Influx Technology website. Notes •Before proceeding with the installation, please ensure that you have acquired administrative privileges.
  • Page 20 ReXgen 2: Product Manual point). • Select the folder where you wish to install the Software; it is preferred to use the default location. • Select the preference for computer user installation to determine which computer users will have access to the ReXdesk Software.
  • Page 21: Driver Installation

    ReXgen 2: Product Manual • Once the installation is complete, this window will appear. • Click 'Close' to close the window. ReXdesk is now successfully installed on your system. 3.3 DRIVER INSTALLATION To install the ReXgen2 driver, locate the ReXgen2 Drivers installer from the start menu.
  • Page 22 ReXgen 2: Product Manual • Click 'Next' to continue installing the ReXgen device driver on your system. • To cancel the installation at this stage, click 'Cancel'. (No software will have been installed on the system at this point.) •...
  • Page 23: Rexgen2 As A J2534 Tool

    ReXgen 2: Product Manual 3.4 ReXgen2 as a J2534 tool • Download the J2534 driver and execute the file. • Click 'Install.' After successful installation, Windows Registry should contain J2534 ReXgen properties. 3.5 FIRMWARE UPDATE All newly released firmware updates will be available on www.influxtechnology.com...
  • Page 24: Annexures

    ReXgen 2: Product Manual 4. ANNEXURES This chapter contains technical data and certificates. 4.1 DIGITAL INPUT FUNCTION The Digital Input Output pins will consider voltages below 0.8V to be low and above 2.5V to be high. Below are examples of how you could utilise the I/O pins if configured as inputs.
  • Page 25: Certifications

    ReXgen 2: Product Manual 4.2 CERTIFICATIONS © I n f l u x T e c h n o l o g y . 24 | P a g e...
  • Page 26 ReXgen 2: Product Manual © I n f l u x T e c h n o l o g y . 25 | P a g e...
  • Page 27: Rohs

    ReXgen 2: Product Manual ROHS © I n f l u x T e c h n o l o g y . 26 | P a g e...
  • Page 28: Can Overview

    ReXgen 2: Product Manual 4.3 CAN OVERVIEW CAN stands for "Controller Area Network" and is defined in the ISO 11898 specification. The Controller Area Network (CAN, also known as CAN Bus) is a vehicle bus standard designed to allow electronic control units and devices to communicate in applications without a host computer. As an...
  • Page 29 ReXgen 2: Product Manual The maximum length achievable is 500 metres at a lower speed of 125 Kbps. • The bus should be terminated at both ends with 120-ohm resistance. • • Removal of one node will not affect the communication in the bus.
  • Page 30 Influx Technology Headquaters Office Suite 22, Building 03 Millbrook Proving Ground, Station Lane Millbrook Bedford MK45 2JQ Telephone: +44 (0) 1525 842504 Sales: sales@influxtechnology.com Influx Big Data Solutions Pvt Ltd 3358E, 13th Main Rd, HAL 2nd Stage, Doopanahalli, Indiranagar, Bengaluru, 560008...

This manual is also suitable for:

Inf2110Inf2111Inf2112Inf2113

Table of Contents