Datalogic PWR-240 REDS Installation Manual
Datalogic PWR-240 REDS Installation Manual

Datalogic PWR-240 REDS Installation Manual

Station redundant power supply
Hide thumbs Also See for PWR-240 REDS:

Advertisement

Quick Links

PWR-240 REDS
INSTALLATION MANUAL
Reading Station Redundant Power Supply

Advertisement

Table of Contents
loading

Summary of Contents for Datalogic PWR-240 REDS

  • Page 1 PWR-240 REDS INSTALLATION MANUAL Reading Station Redundant Power Supply...
  • Page 2 Datalogic publications, please let us know via the "Contact" page. Disclaimer Datalogic has taken reasonable measures to provide information in this manual that is complete and accu- rate, however, Datalogic shall not be liable for technical or editorial errors or omissions contained herein, nor for incidental or consequential damages resulting from the use of this material.
  • Page 3: Table Of Contents

    CHAPTER 5. AC LINE VOLTAGE ELECTRICAL CONNECTIONS ........13 AC Line Input Voltage ..................... 13 12 Vdc Power Block Installation (Optional) ..............14 CHAPTER 6. TECHNICAL FEATURES ............... 16 APPENDIX A. ELECTRICAL DIAGRAMS ..............17 PWR-240 REDs Electrical Diagram ................. 17 INSTALLATION MANUAL...
  • Page 4: Preface

    TECHNICAL SUPPORT Support Through the Website Datalogic provides several services as well as technical support through its website. Log on to (www.datalogic.com). For quick access, from the home page click on the search icon , and type in the name of the product you’re looking for.
  • Page 5: Safety Regulations

    Datalogic commercial reference contacts. Since April 20th, 2016 the main European directives applicable to Datalogic products require inclusion of an adequate analysis and assess- ment of the risk(s). This evaluation was carried out in relation to the applicable points of the standards listed in the Declaration of Conformity.
  • Page 6: General View

    10 Protection Earth Block 4 Cable Entry Plate with Grommets 11 “DC OK” Terminal Block 5 Monophase Switching Power Supplies 12 Low Voltage Current Limiting Fuse 6 Decoupling Module 13 24 Vdc Terminal Block 7 AC Line Input Terminal Block PWR-240 REDS...
  • Page 7: Chapter 1. Operating Features

    If for some reason the output voltage is reduced by less than 90% of nominal) these lines open. The major advantage to the PWR-240 REDs redundant power supply is that if a single power supply fails, it can be replaced by qualified personnel without shutting down the system, (hot-swap).
  • Page 8: Short-Circuit Protection

    Since the PWR-240 REDs utilizes two 24 Vdc 10 A power supplies in parallel, they divide the required current evenly and so can provide up to a combined 20 A without going into an overload condition.
  • Page 9 OUTPUT PROTECTION After time (t) in seconds, the MCB opens, interrupting supplied power according to the following table: CURRENT (A) MCB TIME TO TRIP (S) 14.5 16.8 19.2 21.4 The overload condition must be resolved and the MCB must be manually re-armed to restore normal operation.
  • Page 10: Chapter 2. Pre-Installation Checklist

    Optional 12 Vdc Power Block for RFID Applications Mount the 12 Vdc Power Block inside the cabinet, prepare the AC cord and con- nect it to the AC input terminals as described in " 12 Vdc Power Block Installation (Optional)" on page 14 PWR-240 REDS...
  • Page 11: System Wiring: Ac Input

    PWR powers up correctly. On each supply the green DC-OK light should be on steady and the overload light (red) should off. 7. Close and lock the PWR enclosure and check that it does not open (lock functions correctly). The PWR-240 REDs installation is now complete. INSTALLATION MANUAL...
  • Page 12: Chapter 3. Mechanical Installation

    IMPORTANT: The cabinet must be installed vertically in such a way that the key lock is no higher than 1.90 m from the ground (see Figure 6). Figure 6 – PWR-240 REDs cabinet max. height Please note that the cabinet door can be unlocked and opened by using the key pro- vided along with the product.
  • Page 13: Chapter 4. Low Voltage Electrical Connections

    CHAPTER 4 LOW VOLTAGE ELECTRICAL CONNECTIONS DC LOW VOLTAGE CABLE INSERTION The Cable Entry Plate has several forms of sealing grommets that must be inserted to provide IP65 protection capability. This includes AS-I cable sealing grommets. Cable Entry Plate Follow these instructions to correctly insert the cables: 1.
  • Page 14: As-I Cable Insertion

    DC Outputs Figure 9 – PWR-240 REDs DC Output Power Connections The terminal block marked with the ground symbol is a special block which allows direct connection of the Protection Earth with the enclosure of the PWR-240 REDs. PWR-240 REDS...
  • Page 15: Dc Ok Monitoring

    • T2013, T2014 monitor the T20 Power Supply NOTE: The PWR-240 REDs allows the station to continue functioning even in the event of a single internal power supply failure. Therefore it is strongly recommended to connect the DC OK signals to digital alarms in order to be warned about the loss of the redundant power supply.
  • Page 16: Laser Barcode Scanners

    See the specific scanner manual for consumption data. The maximum number of same type scanners to be supplied for direct wiring by a single PWR-240 REDs is shown in the table below and depends on the wiring topology: MAXIMUM NUMBER OF SCANNERS BY...
  • Page 17: As-I Wiring Topologies

    LASER BARCODE SCANNERS AS-I Wiring Topologies 200 W max device nodes 24 Vdc AS-I single branch with end cap Figure 12 – Single Branch Topology 240 W max total of all devices 200 W max for a single branch device nodes 24 Vdc AS-I double branch with end caps Figure 13 –...
  • Page 18: Installing Accessory Industrial Ethernet Switch

    (marked F1020+ and R1020 -) to the DC low voltage ter- minal block and to the Ethernet Switch terminals as shown in the figure below. Figure 15 - Industrial Ethernet Switch Mounted Inside PWR-240 REDs Route the Ethernet Cables through the Cable Entry Plate grommets to the devices.
  • Page 19: Chapter 5. Ac Line Voltage Electrical Connections

    10 kA max. • Wiring methods from the branch circuit breaker to the PWR-240 REDs power sup- ply shall comply with the National Electric Code ANSI\NFPA. The Datalogic DWS- SWITCH is an AC Power Disconnector and Distributor cabinet which provides this protection.
  • Page 20: Vdc Power Block Installation (Optional)

    Figure 16 – PWR-240 REDs AC Line Terminal Block with Protection Covers 12 VDC POWER BLOCK INSTALLATION (OPTIONAL) A DC Power Block can be installed inside the PWR-240 REDs to supply RFID devices with 12 Vdc. Figure 17 - 12 Vdc Power Block The DC Power Block connects to the AC input line and Its AC cord must be adapted to connect to the PWR AC input terminal block.
  • Page 21 12 VDC POWER BLOCK INSTALLATION (OPTIONAL) Cut the power block AC cord to about 30 cm (12 in) from the female plug and strip the individual wires about 4 cm (1.5 in). Figure 18 - AC Cord Preparation Fix the Power Block to the holder and connect the AC cord to the AC Line terminal block as shown in the figure below.
  • Page 22: Chapter 6. Technical Features

    500 x 400 x 210 mm Mechanical Dimensions HxLxD (19.7 x 15.8 x 8.3 in) Weight about 16 kg (35.7 lbs) * when cables are inserted into the proper grommets of the cable entry plate and all unused posi- tions are sealed. PWR-240 REDS...
  • Page 23: Appendix A. Electrical Diagrams

    APPENDIX A ELECTRICAL DIAGRAMS PWR-240 REDS ELECTRICAL DIAGRAM The PWR-240 REDs components are electrically connected as displayed in the following diagram: INSTALLATION MANUAL...
  • Page 24 ELECTRICAL DIAGRAMS Figure 20 - PWR-240 REDs Electrical Diagram PWR-240 REDS...
  • Page 28 © 2020 Datalogic S.p.A. and /or its affiliates • All rights reserved • Without limiting the rights under copyright, no part of this documentation may be reproduced, stored in or introduced into a retrieval system, or transmitted in any form or by any means, or for any purpose, without the express written permission of Datalogic S.p.A.