The Air Fed kit is a compressed air fed respirator which, when supplied with breathable quality compressed air, passes it via a
belt-mounted regulator and flexible tube into a visor. These instructions must be read in full before operating the equipment. Failure
to follow these instructions completely may result in a decrease in protection or no protection at all. This air fed system conforms to
European Standard EN14594:2005. 'Light duty construction compressed air line breathing apparatus incorporating a helmet or hood'.
SELECTION: The appropriate respiratory protection should be selected for the application in hand. Reference should be made to
"Selection Use and Maintenance of Respiratory Protective Devices", available from the HSE.
APPLICATION: The Air Fed system is a class 2A device and will provide protection against airborne dusts, mists, gases and vapours
up to a Nominal Protection Factor (NPF) of 50. Under UK HSE legislation, the Air Fed system has an Assigned Protection Factor (APF)
of 20.
• This system should not be used where the level of contaminant exceeds 20 x the Workplace Exposure Limit (WEL) or where the
contaminant or its level is unknown.
• This system should not be used in oxygen deficient atmospheres.
• This system should not be used below 0°C.
USE:

• Air Supply Specification

• Input pressure: 3.3 bar (47 PSI) at input to supply hose.
• System consumption: 150 litres/minute (5.3cfm) minimum.
NOTE: The air supply must be of breathable quality as defined in EN12021. The air supply system should be equipped with a
pressure relief safety valve.
AIR SUPPLY HOSE SPECIFICATION: The system should be used with a single 5/16" (8mm) supply hose with maximum working
pressure of 15 bar (217 PSI) and maximum length of 10m.
NOTE: The air supply hose is only suitable for use in areas where risk of damage is low and movements of the wearer are
limited. It has no additional antistatic or heat resistant properties.
• Visor Air Supply Specification and Air Flow Indicator Minimum Design Flowrate: 150 litres/min (5.3cfm)
• A whistle is positioned on the regulator attached to the adjustable belt. The whistle is desgined to make a sound when the air drops
below the minimum design flow rate.

REGULATOR SPECIFICATION:

• This regulator has limited adjustment. Do not attempt to over-adjust it.
• This adjustment allows the user to maintain sufficient air flow to the visor when using auxiliary attachments and to adjust for comfort.
• The regulator has an individual serial number. The last two numbers denote the year of manufacture.
BEFORE USE: The following should be performed in an uncontaminated area:
• Check that the air supply pressure and flow available are in accordance with the above air supply specification.
• Inspect the equipment before use for any signs of damage or deterioration. Do not use the equipment if it appears damaged.
• Fit the belt with the regulator attached around the operator's waist with the regulator on the side of the body. Lock the buckle and adjust
the belt to a comfortable tightness.
• Connect the male end of the main air supply hose to the main air supply. Connect the female end of the main air supply hose to the male
inlet of the regulator.
• Examine the visor and replace the visor cover if contaminated, by pulling it off and pushing a new visor cover over the two metal studs.
• Connect the visor to the outlet of the regulator ensuring that it is locked in place.
• Check the air quality from the visor. If an odour is detectable the cause should then be investigated since further pre-filtering will
probably be required.
• If an accessory such as a spray gun or power tool is to be driven from the same compressed air supply tube, ensure that the airflow
indicator shows that sufficient flow is being delivered into the visor when the accessory is consuming the maximum airflow requirement.
JSP AVENGER AIR FED
VISOR KIT N-AF-KIT
EN14594:2005
EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AVENGER AIR FED VISOR KIT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for JSP AVENGER AIR FED VISOR KIT

  • Page 1 JSP AVENGER AIR FED VISOR KIT N-AF-KIT EN14594:2005 The Air Fed kit is a compressed air fed respirator which, when supplied with breathable quality compressed air, passes it via a belt-mounted regulator and flexible tube into a visor. These instructions must be read in full before operating the equipment. Failure to follow these instructions completely may result in a decrease in protection or no protection at all.
  • Page 2 G-N-AF-MC Regulator Filter ©2006-22 JSP Ltd. | G-C-01083_22-05 JSP Safety GmbH. JSP Ltd. OX29 0TA, UK Wiesenstraße 57, 40549 Düsseldorf, DE www.jspsafety.com | technical@jspsafety.com | : +44 1993 826051 Certified by: BSI Group The Netherlands B.V., (NB2797). Certified by :BSI UK (AB0086).

This manual is also suitable for:

N-af-kit

Table of Contents